![Fluke CableAnalyzer DSP-4000 Series Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/fluke/cableanalyzer-dsp-4000-series/cableanalyzer-dsp-4000-series_user-manual_2309835066.webp)
DSP-4000 Series
Users Manual
3-6
Automatic Diagnostics
If an Autotest fails, you can press
F
to see more specific information on the
cause of the failure. Figure 3-3 shows examples of automatic diagnostics displays
for a NEXT failure and an open pin failure.
The arrow in the diagram at the top of the display shows the location of the failure.
The bottom half of the display describes the failure and suggests ways to fix the
fault. When appropriate, softkeys let you see the plot or plots relevant to the
failure. If more than one fault was found, you can use the
$
Next
Fault
and
#
Prev
Fault
softkeys to scroll through the diagnostics displays.
See Chapter 4 for information on the HDTDR
and HDTDX
plots.
oy09c.bmp
Figure 3-3. Examples of Automatic Diagnostics Displays
Содержание CableAnalyzer DSP-4000 Series
Страница 6: ...DSP 4000 Series Users Manual iv...
Страница 8: ...DSP 4000 Series Users Manual vi...
Страница 18: ...DSP 4000 Series Users Manual 1 8...
Страница 60: ...DSP 4000 Series Users Manual 2 42...
Страница 128: ...DSP 4000 Series Users Manual 6 6...
Страница 160: ...DSP 4000 Series Users Manual 7 32...
Страница 186: ...DSP 4000 Series Users Manual 8 26...
Страница 188: ...DSP 4000 Series Users Manual...
Страница 204: ...DSP 4000 Series Users Manual B 14 oy81f bmp Figure B 5 Autotest Report in Graphical Format...
Страница 210: ...DSP 4000 Series Users Manual B 20...
Страница 222: ...DSP 4000 Series Users Manual C 12...