Resistance Fault Location (RFL) Test
The RFL test provides a highly accurate method of locating resistance faults
(shorts, grounds, or crosses), including those that are
too large
for the TDR
test to locate. It does this by using cable gauge and temperature values in a
“nulling bridge” process. In this process, half of a resistance bridge is formed
within the tester, and the faulted pair (strapped at the far end, as prompted)
forms the other half of the bridge. The internal bridge ratio is then changed
until it precisely mirrors the ratio of the faulted leg to the good leg, and is then
used to calculate resistance values to the fault and strap.
Setting Up an RFL Test
To set up an RFL test, select the test on the POTS Toolbox and press
D
(
Setups
). Refer to Table 4-5 for RFL test setup parameters.
Table 4-5. RFL Test Setup Parameters
Parameter Settings
(default in bold)
Cable Gauge
19, 22, 24, 26, or 28 AWG
Cable Temperature
68
°
F (Range = –99 to 199)
Measurement Mode
Normal or High AC Rejection
(See POTS Auto-Test Setups for details)
RFL Fault Pass
Threshold
30
M
e
(Range = 1 M
e
to 30 M
e
)
Multiple Gauge Entry
Limits
Section Length (Range = 0 to 9999 ft.)
Gauge / mm (Same as Cable Gauge)
Load (Y or N)
Содержание 990DSL
Страница 4: ......
Страница 12: ...990DSL Users Manual viii...
Страница 26: ...990DSL Users Guide 1 12...
Страница 64: ...990DSL Users Guide 3 26...
Страница 138: ...990DSL Users Guide 4 74...
Страница 202: ...990DSL Users Guide 6 20...
Страница 220: ...990DSL Users Manual 8 6...
Страница 221: ...Appendices Appendix Title Page A Features and Specifications A 1 B Replacement Parts and Accessories B 1...
Страница 222: ...990DSL Users Guide...
Страница 232: ...990DSL Users Guide A 10...
Страница 238: ...990DSL Users Guide B 6...
Страница 242: ...990DSL Users Manual 4 Z Zero Leads utility 3 20...