990DSL
Users Guide
4-12
Shorts & Grounds Test
The Shorts & Grounds test provides a “snapshot” measurement of the
resistances between each leg (TR, TG, and RG) of a pair.
Setting Up a Shorts & Grounds Test
To set up a Shorts & Grounds test, select the test on the POTS Toolbox and
press
D
(
Setups
). Refer to Table 4-3 for test setup parameters.
Table 4-3. Shorts & Grounds Test Setup Parameters
Parameter Settings
(default in bold)
Resist. Fault Pass Threshold
≥
150 K
e
(Range = 2 to 9999)
Cable Gauge
19, 22, 24, 26, or 28 AWG
Cable Temperature
68
°
F (Range = –99 to 199)
Measurement Mode
Normal or High AC Rejection
(See POTS Auto-Test Setups for details)
Shorts & Grounds Test Results
To run a Shorts & Grounds test, select it on the POTS Toolbox and press
K
.
In Figure 4-6, the Shorts & Grounds test detected a short (
Tip-Ring Short
) on
the pair, due to a fault resistance reading (
500
Ω
) that is outside the acceptable
limits (as defined in the setup for the test). This reading is shown in flashing,
reverse video format.
Содержание 990DSL
Страница 4: ......
Страница 12: ...990DSL Users Manual viii...
Страница 26: ...990DSL Users Guide 1 12...
Страница 64: ...990DSL Users Guide 3 26...
Страница 138: ...990DSL Users Guide 4 74...
Страница 202: ...990DSL Users Guide 6 20...
Страница 220: ...990DSL Users Manual 8 6...
Страница 221: ...Appendices Appendix Title Page A Features and Specifications A 1 B Replacement Parts and Accessories B 1...
Страница 222: ...990DSL Users Guide...
Страница 232: ...990DSL Users Guide A 10...
Страница 238: ...990DSL Users Guide B 6...
Страница 242: ...990DSL Users Manual 4 Z Zero Leads utility 3 20...