background image

 

Pressure Calibrator 

 

How to Contact Fluke   

 

 

 

27 

LIMITED WARRANTY & LIMITATION OF LIABILITY 

This Fluke product will be free from defects in material and workmanship 
for three years (one year for pump assembly) from the date of purchase. 
This warranty does not cover fuses, disposable batteries or damage from 
accident, neglect, misuse or abnormal conditions of operation or handling. 
Resellers are not authorized to extend any other warranty on Fluke’s 
behalf. To obtain service during the warranty period, send your defective 
Calibrator to the nearest Fluke Authorized Service Center with a 
description of the problem. 

THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER 
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, 
ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY 
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES 
OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some 
states or countries do not allow the exclusion or limitation of an implied 
warranty or of incidental or consequential damages, this limitation of 
liability may not apply to you. 

How to Contact Fluke 

To order accessories, receive operating assistance, or get 
the location of the nearest Fluke distributor or Service 
Center, call: 

USA:  1-888-99-FLUKE (1-888-993-5853) 
Canada:  1-800-36-FLUKE (1-800-363-5853) 
Europe:  +31 402-675-200 
Japan:  +81-3-3434-0181 
Singapore:  +65-738-5655 
Anywhere in the world:  +1-425-446-5500 

Or, visit Fluke's Web site at 

www.fluke.com

Address correspondence to: 

Fluke Corporation 

Fluke Europe B.V. 

P.O. Box 9090, 

P.O. Box 1186, 

Everett, WA 98206-9090   

5602 BD Eindhoven 

U.S.A. The 

Netherlands 

 

Содержание 718 Series

Страница 1: ...718 Series Pressure Calibrator Users Manual July 1998 Rev 4 3 06 1998 2006 Fluke Corporation All rights reserved Printed in U S A All product names are trademarks of their respective companies...

Страница 2: ......

Страница 3: ...Zeroing with Absolute Pressure Modules 9 Calibrating a P I Transmitter 10 Using the Internal Pump 10 Pump Valve Assembly Cleaning Instructions 15 Using an External Pump 16 External Fluke Pressure Mod...

Страница 4: ...ers Manual ii Replacing the Batteries 21 Parts and Accessories 22 Specifications 25 Pressure Sensor Input 25 Pressure Module Input 25 DC mA Input 25 Loop Supply 25 General Specifications 26 How to Con...

Страница 5: ...tle Page 1 Input Units 2 2 Safety Information 3 3 International Electrical Symbols 5 4 Pushbutton Functions 7 5 Pump Features 10 6 Recommended Pressure Modules 14 7 Fluke Pressure Module Compatibility...

Страница 6: ...718 Series Users Manual iv...

Страница 7: ...ique 5 2 Front Panel Features 6 3 Pump Features 9 4 Internal Pressure Sensor with Internal Pump 12 5 Pressure Module with Internal Pump 13 6 Pressure Module with External Pump 17 7 Sourcing Loop Volta...

Страница 8: ...718 Series Users Manual vi...

Страница 9: ...C bar mbar kg cm 2 inHg and mmHg Pressure sensor specifications are as listed under Pressure Sensor Input The Calibrator measures pressure sensor inputs in the units shown in Table 1 For pressure modu...

Страница 10: ...C cmH2O at 4 C cmH2O at 20 C bar mbar kPa inHg mmHg kg cm 2 Safety Information Use the Calibrator only as specified in this Users Manual otherwise the protection provided by the Calibrator may be imp...

Страница 11: ...s from the Calibrator before you open the battery door Make sure the battery door is closed and latched before you operate the Calibrator Do not operate the Calibrator if it is damaged Do not operate...

Страница 12: ...do not apply pressure that exceeds the limits listed in the Pressure Specifications table in the Specifications section To avoid mechanically damaging the Calibrator do not apply torque between the pr...

Страница 13: ...nal Electrical Symbols Symbol Meaning J Earth ground I Fuse M Battery W Refer to this instruction sheet for information about this feature X Hazardous voltage Risk of electric shock T Double insulated...

Страница 14: ...Figure 3 and described in Table 5 Power Saver The Calibrator automatically turns off after 30 minutes of inactivity To reduce this time or disable this feature 1 With the Calibrator OFF press O 2 P S...

Страница 15: ...to confirm selection of 0 and 100 output parameters Z Press to zero the pressure display Vent pressure to atmosphere before you press this pushbutton With an Absolute Pressure Module see special inst...

Страница 16: ...and zero the Calibrator if necessary Close the vent after zeroing the Calibrator 3 Press S to enter pressure switch test mode The Calibrator will display CLOSE instead of a mA measurement 4 Apply pre...

Страница 17: ...essure Module Adjust the Calibrator reading as follows 1 Press and hold Z 2 Press a Z to increase or h Y to decrease the Calibrator reading to equal the applied pressure 3 Release Z to exit the zeroin...

Страница 18: ...itter and measure the transmitter s current loop output You can apply pressure with the Calibrator s internal pump or with an external pump XW Warning To avoid a violent release of pressure or vacuum...

Страница 19: ...ired position Forward clockwise is for pressure backward counter clockwise is for vacuum 4 Turn the pressure vacuum release control backward counter clockwise to vent pressure vacuum from the pump 5 P...

Страница 20: ...MAX 5 PSI P 7 O 7 kP MIN MAX SWITCH TEST COM mA 30V MAX 0 30psi 0 206kPa RANGE S I G N A L T E S T Red Black 718 PRESSURE CALIBRATOR HOLD UNITS ZERO DAMP HOLD LOOP POWER BAROMETRIC ADJ wh002f eps Figu...

Страница 21: ...E O 1 PSI MAX 5 PSI P 7 O 7 kP MIN MAX SWITCH TEST COM mA 30V MAX 0 30psi 0 206kPa RANGE UNITS ZERO DAMP HOLD LOOP POWER BAROMETRIC ADJ S I G N A L T E S T Pressure Module Red Black 718 PRESSURE CALIB...

Страница 22: ...X 700 P23 X X X X 700 P04 X X X X 700 P24 X X X X 700 P05 X X X X 700 P06 X X X 700 P27 X X 700 P07 X 700 P08 X 700 P09 X External pump Internal Pump Pressure Module All 718 models 718 1G 718 30G 718...

Страница 23: ...veral times and check again for residue 6 Clean the o ring assembly and o ring on the retention caps with IPA and inspect the o rings closely for any cuts nicks or wear Replace if needed 7 Inspect the...

Страница 24: ...ource that exceeds the maximum rated pressure To develop higher pressure or vacuum use an external pump such as the Fluke Model 700PTP Use a Fluke Pressure Module connected to the pressure module inpu...

Страница 25: ...1 PSI 5 PSI P O 7 kP MIN MAX SWITCH TEST COM mA 30V MAX 0 30psi 0 206kPa RANGE S I G N A L T E S T Pressure Module Red Black 718 PRESSURE CALIBRATOR HOLD UNITS ZERO DAMP HOLD LOOP POWER BAROMETRIC AD...

Страница 26: ...read Refer to Table 7 for appropriate unit and range compatibility Table 7 Fluke Pressure Module Compatibility Pressure Unit Module Compatibility psi Available on all pressure ranges inH2 0 All ranges...

Страница 27: ...yed in two alternative modes Percent Mode The current is displayed as a percentage based on a 4 20 mA scale Percent Error Mode Transmitter current output error is displayed Error is calculated based o...

Страница 28: ...tion instructions properly Review this instruction sheet to make sure you are using the Calibrator correctly If the Calibrator needs repair and the Calibrator is under warranty see the warranty statem...

Страница 29: ...ears on the display replace the two 9 V alkaline batteries Refer to Figure 8 XW Warning To avoid false readings which could lead to possible electric shock or personal injury replace the batteries as...

Страница 30: ...614487 2 Holster Holster Yellow 664182 1 H2 3 4 Case screw 832246 3 H5 6 Battery door fasteners 948609 2 H7 8 Bracket screw 641131 2 MP1 LCD bezel 718 30G 664158 1 MP1 LCD bezel 718 100G 664169 1 MP1...

Страница 31: ...664174 1 MP89 90 Non skid foot 885884 2 MP92 Battery door 664177 1 S1 Keypad 2113087 1 TL20 Industrial test lead set 1639457 Opt TL75 Test lead set 855742 1 TM1 718 Product Overview Manual 1549632 1...

Страница 32: ...Users Manual 24 AC72 Alligator Clips TL75 Test Lead Set TMI MP1 H7 8 H2 3 4 H5 6 MP2 S1 Holster MP85 MP14 MP5 MP7 MP8 MP10 MP9 MP86 MP3 4 MP11 12 13 MP6 MP89 90 BT1 BT2 MP92 wh004f eps Figure 9 Replac...

Страница 33: ...5 kPa 30G 12 to 30 PSI 83 to 207 kPa 60 PSI 413 kPa 100G 12 to 100 PSI 83 to 690 kPa 200 PSI 1 4 mPa 300G 12 to 300 PSI 83 to 2068 kPa 0 05 of Range 375 PSI 2 6 mPa Temperature coefficient 0 01 of ran...

Страница 34: ...p to 50 C and 35 up to 55 C Vibration Random 2 g 5 Hz to 500 Hz per MIL PRF 28800F Class 2 Shock 1 meter drop test per IEC 61010 1 Safety Certified as compliant to ISA 82 02 01 IEC 61010 1 Mod CSA C22...

Страница 35: ...FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED FLUKE IS NOT LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING FROM ANY CAUSE OR THEORY Since some states or count...

Страница 36: ...718 Series Users Manual 28...

Отзывы: