Pressure Calibrator 

 

 

 

Users Manual 

  

July 1998 Rev. 4, 3/06 

© 1998-2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 

All product names are trademarks of their respective companies. 

Shop for Fluke products online at:

1.888.610.7664

www.

MyFlukeStore

.com

Содержание 718 100G

Страница 1: ...Users Manual July 1998 Rev 4 3 06 1998 2006 Fluke Corporation All rights reserved Printed in U S A All product names are trademarks of their respective companies Shop for Fluke products online at 1 88...

Страница 2: ...ules 9 Calibrating a P I Transmitter 10 Using the Internal Pump 10 Pump Valve Assembly Cleaning Instructions 15 Using an External Pump 16 External Fluke Pressure Module Compatibility 18 Sourcing Loop...

Страница 3: ...es 21 Parts and Accessories 22 Specifications 25 Pressure Sensor Input 25 Pressure Module Input 25 DC mA Input 25 Loop Supply 25 General Specifications 26 How to Contact Fluke 27 Shop for Fluke produc...

Страница 4: ...nformation 3 3 International Electrical Symbols 5 4 Pushbutton Functions 7 5 Pump Features 10 6 Recommended Pressure Modules 14 7 Fluke Pressure Module Compatibility 18 8 Replacement Parts 22 Shop for...

Страница 5: ...ump Features 9 4 Internal Pressure Sensor with Internal Pump 12 5 Pressure Module with Internal Pump 13 6 Pressure Module with External Pump 17 7 Sourcing Loop Voltage 19 8 Battery Replacement 21 9 Re...

Страница 6: ...essure sensor specifications are as listed under Pressure Sensor Input The Calibrator measures pressure sensor inputs in the units shown in Table 1 For pressure modules full scale readings for all pre...

Страница 7: ...bar kPa inHg mmHg kg cm 2 Safety Information Use the Calibrator only as specified in this Users Manual otherwise the protection provided by the Calibrator may be impaired A Warning identifies conditio...

Страница 8: ...en the battery door Make sure the battery door is closed and latched before you operate the Calibrator Do not operate the Calibrator if it is damaged Do not operate the Calibrator around explosive gas...

Страница 9: ...the limits listed in the Pressure Specifications table in the Specifications section To avoid mechanically damaging the Calibrator do not apply torque between the pressure fitting and the Calibrator c...

Страница 10: ...ng J Earth ground I Fuse M Battery W Refer to this instruction sheet for information about this feature X Hazardous voltage Risk of electric shock T Double insulated Conforms to relevant Canadian Stan...

Страница 11: ...Power Saver The Calibrator automatically turns off after 30 minutes of inactivity To reduce this time or disable this feature 1 With the Calibrator OFF press O 2 P S xx is displayed where xx is the tu...

Страница 12: ...output parameters Z Press to zero the pressure display Vent pressure to atmosphere before you press this pushbutton With an Absolute Pressure Module see special instructions below N Press to read the...

Страница 13: ...ry Close the vent after zeroing the Calibrator 3 Press S to enter pressure switch test mode The Calibrator will display CLOSE instead of a mA measurement 4 Apply pressure with the pump slowly until th...

Страница 14: ...reading as follows 1 Press and hold Z 2 Press a Z to increase or h Y to decrease the Calibrator reading to equal the applied pressure 3 Release Z to exit the zeroing procedure Press the U button to c...

Страница 15: ...current loop output You can apply pressure with the Calibrator s internal pump or with an external pump XW Warning To avoid a violent release of pressure or vacuum always depressurize the system slow...

Страница 16: ...for pressure backward counter clockwise is for vacuum 4 Turn the pressure vacuum release control backward counter clockwise to vent pressure vacuum from the pump 5 Press Z to zero the pressure display...

Страница 17: ...TEST COM mA 30V MAX 0 30psi 0 206kPa RANGE S I G N A L T E S T Red Black 718 PRESSURE CALIBRATOR HOLD UNITS ZERO DAMP HOLD LOOP POWER BAROMETRIC ADJ wh002f eps Figure 4 Internal Pressure Sensor with...

Страница 18: ...MAX SWITCH TEST COM mA 30V MAX 0 30psi 0 206kPa RANGE UNITS ZERO DAMP HOLD LOOP POWER BAROMETRIC ADJ S I G N A L T E S T Pressure Module Red Black 718 PRESSURE CALIBRATOR HOLD wh010f eps Figure 5 Pres...

Страница 19: ...00 P24 X X X X 700 P05 X X X X 700 P06 X X X 700 P27 X X 700 P07 X 700 P08 X 700 P09 X External pump Internal Pump Pressure Module All 718 models 718 1G 718 30G 718 100G 718 300G 700 PA3 X X X X 700 P...

Страница 20: ...idue 6 Clean the o ring assembly and o ring on the retention caps with IPA and inspect the o rings closely for any cuts nicks or wear Replace if needed 7 Inspect the springs for wear or loss of tensio...

Страница 21: ...d pressure To develop higher pressure or vacuum use an external pump such as the Fluke Model 700PTP Use a Fluke Pressure Module connected to the pressure module input on the Calibrator Pressure module...

Страница 22: ...H TEST COM mA 30V MAX 0 30psi 0 206kPa RANGE S I G N A L T E S T Pressure Module Red Black 718 PRESSURE CALIBRATOR HOLD UNITS ZERO DAMP HOLD LOOP POWER BAROMETRIC ADJ MAX wh006f eps Figure 6 Pressure...

Страница 23: ...te unit and range compatibility Table 7 Fluke Pressure Module Compatibility Pressure Unit Module Compatibility psi Available on all pressure ranges inH2 0 All ranges through 3000 psi cmH2 0 All ranges...

Страница 24: ...t Mode The current is displayed as a percentage based on a 4 20 mA scale Percent Error Mode Transmitter current output error is displayed Error is calculated based on a configurable zero and span pres...

Страница 25: ...his instruction sheet to make sure you are using the Calibrator correctly If the Calibrator needs repair and the Calibrator is under warranty see the warranty statement for terms If the warranty has l...

Страница 26: ...9 V alkaline batteries Refer to Figure 8 XW Warning To avoid false readings which could lead to possible electric shock or personal injury replace the batteries as soon as the battery indicator B app...

Страница 27: ...4182 1 H2 3 4 Case screw 832246 3 H5 6 Battery door fasteners 948609 2 H7 8 Bracket screw 641131 2 MP1 LCD bezel 718 30G 664158 1 MP1 LCD bezel 718 100G 664169 1 MP1 LCD bezel 718 1G 2545047 1 MP1 LCD...

Страница 28: ...884 2 MP92 Battery door 664177 1 S1 Keypad 2113087 1 TL20 Industrial test lead set 1639457 Opt TL75 Test lead set 855742 1 TM1 718 Product Overview Manual 1549632 1 718 CD ROM contains Users Manual 15...

Страница 29: ...s TL75 Test Lead Set TMI MP1 H7 8 H2 3 4 H5 6 MP2 S1 Holster MP85 MP14 MP5 MP7 MP8 MP10 MP9 MP86 MP3 4 MP11 12 13 MP6 MP89 90 BT1 BT2 MP92 wh004f eps Figure 9 Replacement Parts Shop for Fluke products...

Страница 30: ...a 60 PSI 413 kPa 100G 12 to 100 PSI 83 to 690 kPa 200 PSI 1 4 mPa 300G 12 to 300 PSI 83 to 2068 kPa 0 05 of Range 375 PSI 2 6 mPa Temperature coefficient 0 01 of range per C for temperature ranges 10...

Страница 31: ...on Random 2 g 5 Hz to 500 Hz per MIL PRF 28800F Class 2 Shock 1 meter drop test per IEC 61010 1 Safety Certified as compliant to ISA 82 02 01 IEC 61010 1 Mod CSA C22 2 No 1010 1 Protection Class Class...