background image

561R Infrared Thermometer

Quick Reference Guide

PN 2797301  December 2006  

©2006 Fluke Corporation. All rights reserved. Printed in USA.

Features

The Thermometer includes:

•  Single-spot Laser Sighting 

•  Backlit Display

•  Current Temperature Plus MIN, MAX, DIF Temperature  

  Displays

•  Easy Emissivity Selector

•  Type-K Thermocouple

•  Two AA Batteries

• Users 

M

anual on CD

Operating the Thermometer

To measure temperature, pull and hold trigger. Release 

the trigger to hold a temperature reading. The 

thermometer turns off when no activity is detected for 

seven seconds.

Symbol 

 

Explanation

Risk of danger. Important information. See Manual.
Warning. Laser.
Conforms to requirements of European Union and 

European Free Trade Association (EFTA)
Do not dispose of this product as unsorted municipal 

waste. Contact Fluke or a qualified recycler for 

disposal.
Battery
Chinese manufacturing mark for products 

manufactured in the Peoples Republic of China (PRC)

 

Safety Information

Warning

A Warning identifies conditions and actions that pose hazards 

to the user. To avoid electrical shock or personal injury, follow 

these guidelines:

 

 Do not point laser directly at eye or indirectly off  

  reflective surfaces.

  Before using the Thermometer inspect the case. Do not use  

  the Thermometer if it appears damaged. Look for cracks or  

  missing plastic. 

  Replace the batteries as soon as the battery indicator (   )  

  appears. 

  Do not use the Thermometer if it operates abnormally.  

  Protection may be impaired. When in doubt, have the  

  Thermometer serviced. 

  Do not operate the Thermometer around explosive gas,  

  vapor, or dust. 

  Do not connect the optional external probe to live electrical  

  circuits.

  To avoid a burn hazard, remember that highly reflective  

  objects will often result in lower than actual temperature  

  measurements.

  Do not use in a manner not specified by this guide or users  

  manual or the protection supplied by the equipment may be  

  impaired.
 

Caution

To avoid damaging the thermometer or the equipment under 

test protect them from the following:

•  EMF (electro-magnetic fields) from arc welders, induction  

  heaters, etc.

•  Static electricity.

•  Thermal shock (caused by large or abrupt ambient  

  temperature changes- allow 30 minutes for the   

  Thermometer to stabilize before use).

•  Do not leave the Thermometer on or near objects of high  

  temperature.

Symbols

Button 

  

       Description

Battery Replacemant

Thermometer Buttons

Press
MAX, and DIF options.

 and then press   to toggle between the MIN, 

The   button is used to show the MIN, MAX, and DIF  
functions in the secondary display, whichever was pressed 

most recently.

Selects the emissivity setting. You can toggle between LO 
(0.3), MED (0.7), or HI (0.95) using      

You may need

to adjust emissivity for shiny metalic objects. 

AA

Batteries

(2)

(+)

Laser

Trigger

Battery

Cover

Battery door

locking latch

Function Buttons

Display