FW_F112A_v1702_02_EN
Page 21
4.4.2.
ALUMINUM ENCLOSURE - FIELD MOUNTED
Risk of damage to equipment!
Do not use the terminal 00 to connect the protective earth wire, the 00 and the common
ground terminals are internally connected. Be careful, to prevent damage to equipment when
you connect different power supplies (sensor, PLC, etc.). Inside the Fluidwell display, the
common grounds are internally connected to each other.
The PE connection
The PE connection is made with the PE stud
inside the back panel and the 4 mounting
screws that attach the cover to the back panel.
Type PM (110-230V AC)
The PE connection in the
metal back panel is made
with a serrated washer, a
terminal, a washer and a
screw.
The PE connection to the
metal cover is made with the
serrated washers and the
mounting screws.
Type OR (8-24V AC)
Type OR (8-30V DC)
4.4.3.
ALUMINUM ENCLOSURE - PANEL MOUNTED
The PE connection
The PE connection is made with one of the
mounting screws that attaches the front panel
to the panel.
Type PM (110-230V AC)
The PE connection to the
metal cover is made with the
serrated washers and the
mounting screws.
The PE connection to the
panel is made with the
washer, the nut, the
terminal, the washer and a
lock nut.
Type OR (8-24V AC)
Type OR (8-30V DC)