background image

 

 

IPS WIRELESS SELD-102 Node ENGLISH 702-3001 07-17 

 

Page 

3

 of 

22

 

  

   

 

 

 

flowserve.com

 

 

1  INTRODUCTION AND SAFETY 

 

1.1  General 

 

These instructions must always be kept 

close to the product's operating location or 
directly with the product.

 

 
Flowserve products are designed, developed and 
manufactured with state-of-the-art technologies in 
modern facilities.  The unit is produced with great 
care and commitment to continuous quality control, 
utilizing sophisticated quality techniques, and 
safety requirements. 
 
Flowserve is committed to continuous quality 
improvement and being at your service for any 
further information about the product in its 
installation and operation or about its support 
products, repair and diagnostic services. 
 
These instructions are intended to facilitate 
familiarization with the product and its permitted 
use.  Operating the product in compliance with 
these instructions is important to help ensure 
reliability in service and avoid risks.  The 
instructions may not take into account local 
regulations; ensure such regulations are observed 
by all, including those installing the product.  
Always coordinate repair activity with operations 
personnel, and follow all plant safety requirements 
and applicable safety and health laws/regulations. 

 

These instructions must be read prior to 

installing, operating, using and maintaining the 
equipment in any region worldwide.  The 
equipment must not be put into service until all 
the conditions relating to safety, noted in the 
instructions, have been met.  Failure to follow 
and apply the present user instructions is 
considered to be misuse.  Personal injury, 
product damage, delay or failure caused by 
misuse are not covered by the Flowserve 
warranty. 

 

1.2  CE Marking and approvals 

It is a legal requirement that machinery and 
equipment put into service within certain regions of 
the world shall conform with the applicable CE 
Marking Directives covering Machinery and, where 
applicable, Low Voltage Equipment, Electromagnetic 
Compatibility (EMC), Pressure Equipment Directive 
(PED) and Equipment for Potentially Explosive 
Atmospheres (ATEX). 
 

Where applicable, the Directives and any additional 
Approvals, cover important safety aspects relating to 
machinery and equipment and the satisfactory 
provision of technical documents and safety 
instructions.  Where applicable this document 
incorporates information relevant to these Directives 
and Approvals. 
 
To confirm the Approvals applying and if the product 
is CE marked, check the serial number plate 
markings and the Certification.  (See section 

Error! 

Reference source not found.

.) 

 

1.3  Disclaimer 

Information in these User Instructions is believed 
to be complete and reliable.  However, in spite of 
all of the efforts of Flowserve Corporation to 
provide comprehensive instructions, good 
engineering and safety practice should always be 
used.

 

 
Flowserve manufactures products to exacting 
International Quality Management System Standards 
as certified and audited by external Quality Assurance 
organizations.  Genuine parts and accessories have 
been designed, tested and incorporated into the 
products to help ensure their continued product 
quality and performance in use.  As Flowserve cannot 
test parts and accessories sourced from other 
vendors the incorrect incorporation of such parts and 
accessories may adversely affect the performance 
and safety features of the products.  The failure to 
properly select, install or use authorized Flowserve 
parts and accessories is considered to be misuse.  
Damage or failure caused by misuse is not covered 
by the Flowserve warranty.  In addition, any 
modification of Flowserve products or removal of 
original components may impair the safety of these 
products in their use. 
 

1.4  Copyright 

All rights reserved.  No part of these instructions 
may be reproduced, stored in a retrieval system or 
transmitted in any form or by any means without 
prior permission of Flowserve. 
 

1.5  Duty conditions 

This product has been selected to meet the 
specifications of your purchase order.  The 
acknowledgement of these conditions has been 
sent separately to the Purchaser.  A copy should be 
kept with these instructions. 

 

The product must not be operated beyond 

the parameters specified for the application.  If 

Содержание IPS Wireless SELD-102

Страница 1: ...Installation Operation Maintenance Single Port Condition Monitor and Wireless Transmitting Unit PCN 702 3001 07 17 E Original Instructions These instructions must be read prior to installing operating using and maintaining this equipment 702 3001 ...

Страница 2: ...RUCTIONS 6 3 DESCRIPTION 6 3 1 OPTIONS AND MODEL NUMBERS 7 3 2 DEFAULT CONFIGURATION 7 3 3 ALARM MODE 7 3 4 PERFORMANCE AND OPERATION LIMITS 8 4 MAINTENANCE 8 4 1 TOOLS REQUIRED 8 4 2 TURNING UNIT ON OFF 8 4 3 BATTERY REPLACEMENT 9 5 CUSTOM CONFIGURATION PROGRAMMING 9 6 INSTALLATION 10 6 1 TOOLS REQUIRED 10 6 2 PRELIMINARY OPERATIONAL CHECK 10 6 3 MOUNTING 10 6 4 CONNECTING SENSORS AND POWER UP 11...

Страница 3: ...uipment Directive PED and Equipment for Potentially Explosive Atmospheres ATEX Where applicable the Directives and any additional Approvals cover important safety aspects relating to machinery and equipment and the satisfactory provision of technical documents and safety instructions Where applicable this document incorporates information relevant to these Directives and Approvals To confirm the A...

Страница 4: ...assembly process 1 6 2 Personnel qualification and training All personnel involved in the operation installation inspection and maintenance of the unit must be qualified to carry out the work involved If the personnel in question do not already possess the necessary knowledge and skill appropriate training and instruction must be provided If required the operator may commission the manufacturer su...

Страница 5: ...ived from factory and remove protective wrapping from SELD 102 Node units and accessories Inspect all hardware for damage Report any damage to shipping carrier immediately Ensure you have received the correct sensors and mounting accessories for your application Cross check hardware received versus packing slip and purchase order Record unit serial numbers for future reference 2 1 2 Electrostatic ...

Страница 6: ... DESCRIPTION The SELD 102 Node X where X designates a specific hardware configuration per order model is a wireless transmitting unit designed to monitor one single or combination sensor input and wirelessly transmit the data to a receiver The SELD 102 Node also provides two LED indicator lights for a quick visualization of equipment health See 6 5 LED Indications The SELD 102 Node is a self power...

Страница 7: ... complete list of the different sensors that can be built in to each SELD 102 Node is shown below along with the appropriate model number Table 2 Board Numbers Option Sensor Type 4 20 BP 4 20mA Analog Input Sensor P Pressure Sensor P T Pressure Temperature Sensor DP Differential Pressure Sensor SW BP Discrete Sensor monitors dry contact closure TRTD Temperature 1000 Ohm Platinum RTD type Sensor VV...

Страница 8: ...ween 2 8 and 3 6 VDC If it is lower than this the battery will need to be replaced The battery voltage can be read at the receiver or through the PSP software when connected directly to the SELD 102 Node unit refer to PSP software user instructions for details on how to do this See table Table 5 SELD 102 Node approximate battery life at various measurement intervals under ideal conditions for appr...

Страница 9: ...ging the battery Figure 3 SELD 102 Node unit battery with unit external housing removed Figure 4 SELD 102 Node unit battery nuts holding battery in place 6 Install new battery pack part number S1 1061 Reinstall battery mounting nuts reconnect battery pack connector 7 Install tube back onto unit and tighten tube 8 Reinstall SELD 102 Node unit in the field 9 Dispose of old battery pack in accordance...

Страница 10: ...approval from the factory Ensure the SELD 102 Node is not subjected to excessive vibration unless a routine maintenance program includes verification of associated connections When installing a pressure sensor SELD 102 Node unit it is recommended that a block and bleed valve assembly be used for ease of maintenance Attach any sensors before mounting and securing the SELD 102 Node separately if req...

Страница 11: ...able 6 Specific Sensor Connection Instructions Sensor Type Connection Instructions 4 20mA This device is polarity sensitive The red wire must connect to the MOST positive power of the loop Reversed polarity will result in damage to the device Discrete Wiring carries no voltage but will detect a contact closure Change of state on the contacts will determine the state of the signal transmitted The S...

Страница 12: ...ring start up Recommended quantities of 2 year operational spares are listed below Table 8 S SELD 102 Node Spare Parts Part Number Description 2 Year Operational Spares S1 1061 Replacement Lithium Battery Pack 1 dependent on transmit interval selected M1 0124 Replacement Outer Tube Red PVC tube with clear lens dwg 100 2104 0 M1 0119 Quarter Turn Quick Disconnect Receptacle 0 M1 0120 Quick Disconne...

Страница 13: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 13 of 22 flowserve com 7 2 Drawings Figure 10 Example drawing for SELD 102 Node VA ...

Страница 14: ...f voltmeter connection to battery pack cables 8 1 2 Unit not configured correctly To perform the diagnostic steps for this issue the SELD 102 Node unit will need all sensors connected to it Refer to PSP software instructions to reload the original configuration into the SELD 103 unit 8 1 3 Unit out of range of receiver If communications from the SELD 102 Node unit to the receiver are still not suc...

Страница 15: ... WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 15 of 22 flowserve com If none of the above solutions are successful in getting data reception at the receiver contact the factory for additional support ...

Страница 16: ...for the application intended contact the manufacturer for advice The battery pack is NOT re chargeable and shall only be replaced by contacting your local sales representative Battery pack part number S1 1061 EXPLOSION HAZARD The unit must be powered OFF during the battery installation must be in a General Purpose Classified Area to prevent the possible ignition of a hazardous atmosphere WARNING S...

Страница 17: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 17 of 22 flowserve com 9 DECLARATION OF CONFORMITY TYPICAL ...

Страница 18: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 18 of 22 flowserve com ...

Страница 19: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 19 of 22 flowserve com ...

Страница 20: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 20 of 22 flowserve com ...

Страница 21: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 21 of 22 flowserve com ...

Страница 22: ...A and Canada Flowserve Corporation Pump 5215 North O Connor Blvd Suite 2300 Irving Texas 75039 5421 USA Telephone 1 937 890 5838 Europe Middle East Africa Flowserve Corporation Parallelweg 13 4878 AH Etten leur The Netherlands Telephone 31 76 502 8100 Latin America Flowserve Corporation Martin Rodriguez 4460 B1644CGN Victoria San Fernando Buenos Aires Argentina Telephone 54 11 4006 8700 Telefax 54...

Отзывы:

Похожие инструкции для IPS Wireless SELD-102