IPS WIRELESS SELD-102 Node ENGLISH 702-3001 07-17
Page
10
of
22
flowserve.com
6 INSTALLATION
Always wear appropriate personal
protective equipment during the installation of
SELD-102 Node units.
6.1 Tools required
Tools required to install the various mounting
configurations are conditional based on the
type of mounting and location
6.2 Preliminary operational check
After unpacking and before field installation,
perform the following operational check on the unit:
1. Ensure the battery is plugged in and unit on.
2. Place SELD-102 Node unit in vertical position
with a clear line of sight to and close to (<10ft)
of the receiver.
3. Ensure the receiver is receiving data from the
unit.
4. Unplug the battery if the unit is not going to be
installed in the field immediately.
In case of issues with powering up the unit, refer to
section 8 TroubleShooting Guide.
6.3 Mounting
Each unit should be clear of physical obstructions
to the receiver and/or repeater(s) in order to
maintain consistent communications.
The SELD-102 Node is designed to be mounted in
a vertical position and should only be mounted in a
horizontal position with approval from the factory.
Ensure the SELD-102 Node is not subjected to
excessive vibration unless a routine maintenance
program includes verification of associated
connections. When installing a pressure sensor
SELD-102 Node unit, it is recommended that a
block and bleed valve assembly be used for ease
of maintenance.
Attach any sensors before mounting and securing
the SELD-102 Node (separately if required).
Depending on the sensor built-in to each SELD-102
Node unit, the unit may be limited to only one
possible mounting configuration.
6.3.1 Stud mounting option
With this option the SELD-102 Node unit can be
mounted to any surface using a ¼-28 stud.
There is an optional quarter turn quick disconnect
that can be used to assure the orientation of the x-
y-z axis is correct. This mounting configuration is
used for built-in vibration or vibration/temperature
sensors. In the case of a vibration/temperature
sensor, the temperature sensor end will be flush
against the bottom of the SELD-102 Node unit
base to measure temperature of the surface it is in
contact with
.
Figure 5: Stud mounting option
The SELD-102 Node unit may also have a
mounting pad attached to the stud. This mounting
pad can then be attached to any surface using
epoxy.
Figure 6: bottom of SELD-102 Node unit with
quarter turn quick disconnect mounting shown
below
Содержание IPS Wireless SELD-102
Страница 18: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 18 of 22 flowserve com ...
Страница 19: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 19 of 22 flowserve com ...
Страница 20: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 20 of 22 flowserve com ...
Страница 21: ...IPS WIRELESS SELD 102 Node ENGLISH 702 3001 07 17 Page 21 of 22 flowserve com ...