1.6  Safety 

 

1.6.1  Summary of safety markings 

These User Instructions contain specific safety 
markings where non-observance of an instruction 
would cause hazards.  The specific safety markings 
are: 

This symbol indicates electrical safety 

instructions where non-compliance will involve a high 
risk to personal safety or the loss of life. 

 This symbol indicates safety instructions where 

non-compliance would affect personal safety and 
could result in loss of life. 

 This symbol indicates “hazardous and toxic fluid” 

safety instructions where non-compliance would affect 
personal safety and could result in loss of life. 

 This symbol indicates safety 

instructions where non-compliance will involve some 
risk to safe operation and personal safety and would 
damage the equipment or property. 

 This symbol indicates explosive atmosphere 

zone marking according to ATEX.  It is used in safety 
instructions where non-compliance in the hazardous 
area would cause the risk of an explosion. 

 This symbol is used in safety instructions to 

remind not to rub non-metallic surfaces with a dry 
cloth; ensure the cloth is damp. It is used in safety 
instructions where non-compliance in the hazardous 
area would cause the risk of an explosion. 

 This sign is not a safety symbol but indicates 

an important instruction in the assembly process. 
 

1.6.2  Personnel qualification and training 

All personnel involved in the operation, installation, 
inspection and maintenance of the unit must be 
qualified to carry out the work involved.  If the 
personnel in question do not already possess the 
necessary knowledge and skill, appropriate training 
and instruction must be provided.  If required the 
operator may commission the manufacturer/supplier 
to provide applicable training. 
 
Always coordinate repair activity with operations and 
health and safety personnel, and follow all plant 
safety requirements and applicable safety and health 
laws and regulations. 

1.6.3  Safety action 
This is a summary of conditions and actions to 
help prevent injury to personnel and damage to 
the environment and to equipment.  For products 
used in potentially explosive atmospheres 
section 1.6.4 also applies.
 

NEVER DO MAINTENANCE WORK 

WHEN THE UNIT IS CONNECTED TO POWER 
(Lock out.) 

 HANDLING COMPONENTS 

Many precision parts have sharp corners and the 
wearing of appropriate safety gloves and equipment 
is required when handling these components.  To lift 
heavy pieces above 25 kg (55 lb) use a crane 
appropriate for the mass and in accordance with 
current local regulations. 
 

1.6.4  Products used in potentially explosive 
atmospheres 

 Measures are required to: 

 

Avoid excess temperature 

 

Prevent buildup of explosive mixtures 

 

Prevent the generation of sparks 

 

1.7  Specific machine performance 

For performance parameters see section 1.5

  Duty 

conditions

 Where performance data has been supplied 

separately to the purchaser these should be obtained 
and retained with these User Instructions if required. 
 

2  TRANSPORT AND STORAGE 

 Make sure that hazardous substances are 

disposed of safely and that the correct personal 
protective equipment is used.  The safety 
specifications must be in accordance with the current 
local regulations at all times. 
 

2.1  Consignment receipt and unpacking 

Immediately after receipt of the equipment it must be 
checked against the delivery/shipping documents for 
its completeness and that there has been no damage 
in transportation.  Any shortage and/or damage must 
be reported immediately to Flowserve and must be 
received in writing within ten days of receipt of the 
equipment.  Later claims cannot be accepted. 
 
Check any crate, boxes or wrappings for any 
accessories or spare parts that may be packed 
separately with the equipment or attached to side 
walls of the box or equipment. 
 

 

Содержание IPS-Beacon VB-105

Страница 1: ...eration Maintenance Condition monitoring and alert system for vibration and temperature PCN 26999949 03 13 E Original instructions These instructions must be read prior to installing operating using a...

Страница 2: ...ake away memory module TAM 7 4 MAINTENANCE 7 4 1 Tools required 7 4 2 Turning unit on off 7 4 3 Low battery 7 5 CUSTOM CONFIGURATION PROGRAMMING 7 5 1 User configurable settings 7 5 2 Connecting to IP...

Страница 3: ...ty aspects relating to machinery and equipment and the satisfactory provision of technical documents and safety instructions Where applicable this document incorporates information relevant to these D...

Страница 4: ...g Always coordinate repair activity with operations and health and safety personnel and follow all plant safety requirements and applicable safety and health laws and regulations 1 6 3 Safety action T...

Страница 5: ...organic and do not represent environmental hazards once the decomposition or neutralization process has terminated Disposal in Europe Batteries for disposal should not be transported by air For road t...

Страница 6: ...ication can be obtained from Flowserve 3 3 1 IPS Beacon nomenclature Table 3 IPS Beacon nomenclature Flowserve item code Generic designation Specifications Material 9050 VB 105 IPS Beacon compact moni...

Страница 7: ...ollow the power up procedure below To power up the IPS Beacon simply install the PUM to the DB9 on the side of the unit and insert the screw into the PUM tighten screw to 0 7 Nm 6 in lb torque to keep...

Страница 8: ...8 Parts List and Drawings for the Flowserve part number to obtain one For details on connection to the Dock refer to the Dock IOM PCN 26999975 5 3 Setting alarm set points The IPS Beacon unit can have...

Страница 9: ...IPS BEACON ENGLISH 26999949 03 13 Page 9 of 16 flowserve com Figure 3 X Y Z axis orientation Figure 4 IPS Beacon drawing Figure 5 IPS Beacon mounting pad X Y Z...

Страница 10: ...d through the IPS Beacon and threaded into the tap Attach IPS Beacon 9050 to bearing housing 3200 using Phillips head fastener M6 or in x 28 18 8SS stud An alternative is to attach the IPS Beacon to t...

Страница 11: ...IPS Beacon to a threaded tap VB 105 screw Cap screw to attach PUM or TAM to IPS Beacon VB 101 Dock Programming dock to connect IPS Beacon to PC and change configuration settings DockTalk Configuration...

Страница 12: ...n of the unit or improper installation looseness Unit configuration incorrect If the inaccurate missing data problem is across all sensor data parameters reload the original configuration for the IPS...

Страница 13: ...his Declaration refers are in compliance with the Directives and Norms specified herein ATEX Directive 94 9 EC all amendments Basis for compliance The equipment has been assessed using the following s...

Страница 14: ...emonstrate that the product meets the requirements of the Directives has been compiled by the signatory below and is available for inspection by the relevant enforcement authorities Signed ___________...

Страница 15: ...IPS BEACON ENGLISH 26999949 03 13 Page 15 of 16 flowserve com Notes...

Страница 16: ...da Flowserve Corporation 5215 North O Connor Blvd Suite 2300 Irving Texas 75039 5421 USA Telephone 1 972 443 6500 Fax 1 972 443 6800 Europe Middle East Africa Flowserve Worthington S r l Via Rossini 9...

Отзывы: