background image

Worcester Controls

06957-L

1

/

2

"–2" Series 94 and FZ94 Three-Piece Ball Valves,

1

/

2

"–6" Series 94 and FZ94 150/300, 

1"–2" Series 94 600, and 4"–6" Series AF94 150/300
Flanged One-Piece Ball Valves 

Installation, Operation and Maintenance Instructions

CAUTION: Flowserve recommends that all product which must be
stored prior to installation be stored indoors, in an environment
suitable for human occupancy. Do not store product in areas where
exposure to relative humidity above 85%, acid or alkali fumes,
radiation above normal background, ultraviolet light, or
temperatures above 120°F or below 40°F may occur. Do not store
within 50 feet of any source of ozone.

I. INSTALLATION

A. Standard 94 Series three-piece and flanged one-piece valves may

be installed for flow or vacuum in either direction. Use care to
exclude pipe sealants from the valve cavity. Valves with upstream
relief hole in ball (V3 option) are one-way valves.

B. When installing 94, AF94 or FZ94 flanged one-piece valves, use

standard gaskets suitable for the specific service. Tighten flange
bolts or studs evenly. Follow ANSI standards for flange bolt
torque.

C. For Weld End Valves (SW, BW):

NOTES:

Prior to welding, THOROUGHLY CLEAN ALL JOINT

SURFACES to prevent contamination.

Valves with “PG”, “RG”, “XG”, “AG” and “GG” seat/body seal
combinations and V67 option code are compatible with welding
temperatures. Therefore, these valves are weld-as-is and do not
have to be disassembled to be welded in line. A red welding tag
will be attached to the valve. If these valves are disassembled, the

graphite-coated stainless steel gasket body seals (code “G”) and
the seat back seals (used with “A” or “G” seats only) must be
replaced. When welding these valves, the ball must be open to
prevent adhesion of weld spatter to the ball. Use STICK or MIG
welding and allow valve and joint to cool to the touch between
passes.

For All Other Weld End Valves:

1. Tack weld the valve in place.

2. Remove three body bolts, loosen the fourth and swing out the

body with valve open. Close the valve and remove the seats,
ball and body seals.

NOTE:

FZ94 valves can not be swung out. Remove fourth bolt

and spread pipe ends to clear centering ring (Revision R3
FZ94 valves with “G” seats, and all Revision R4 and later
FZ94 valves do not have centering rings). Close valve, remove
ball, seats, body seals.

3. Swing body in and secure it with one additional body bolt

diagonally from first.

4. Weld pipe ends. When gas welding, DO NOT play flame on

the valve body.

5. Allow valve to cool. Reassemble valve. Install new body seals,

or coated stainless steel “S” gaskets (code M or G), if they
were shipped separately from the valve, discarding the
temporary Buna body seals found in the valve as received.
See I.D.3.

Visit www.boighill.com to request a quote.

Visit www.boighill.com to request a quote.

Содержание 94 600 Series

Страница 1: ...V67 option code are compatible with welding temperatures Therefore these valves are weld as is and do not have to be disassembled to be welded in line A red welding tag will be attached to the valve...

Страница 2: ...s open B 94 Series valves will provide bubble tight shutoff when used in accordance with Worcester s published pressure temperature chart with the exception of G seated valves Valves with G seats meet...

Страница 3: ...PM R1 3 FZRK94 RZ R0 2 RK94 AG T0726 CAUTION If the seats and seals installed differ from those removed the valve nameplate MUST be replaced or re marked to indicate the altered materials and ratings...

Страница 4: ...ed to the seat backs Do not operate a newly rebuilt valve with filled metal seats without lubricant If graphite parts are used they should be handled on the flat surfaces rather than the O D These par...

Страница 5: ...ng chamber in this order refer to packing assembly drawings Figures 1 and 2 a For T Packing Filler ring 629 seal lantern ring T three Chevron packing rings for 1 2 2 94 three piece and one piece valve...

Страница 6: ...L Flow Control Division Worcester Controls 3 6 Flanged One Piece Valves T Packing Detail Figure 1 G Packing Detail Figure 2 Visit www boighill com to request a quote Visit www boighill com to request...

Страница 7: ...10b Graphite Ring 1 11a 629 Seal 1 11b Graphite Ring 1 12a Lantern Ring T 1 Part Name Qty 12b Lantern Ring G 1 13a Chevron Ring 3 13b Graphite Ring 2 14 Follower T 1 15 Follower G 1 16 Handle Optional...

Страница 8: ...9 Seal 1 11b Graphite Ring 1 Part Name Qty 12a Lantern Ring T 1 12b Lantern Ring G 1 13a Chevron Ring 3 13b Graphite Ring 2 14 Follower T 1 15 Follower G 1 16 Handle Optional ordered separately 1 17 S...

Страница 9: ...G 1 12a Chevron Ring 3 Part Name Qty 12b Graphite Ring 2 13 Follower T 1 14 Follower G 1 15 Gland Plate 1 16 Gland Bolt 2 17 Belleville Washer 12 18 Stop 1 19 Spacer not always present 1 20 Wrench Blo...

Страница 10: ...10 06957 L Flow Control Division Worcester Controls Visit www boighill com to request a quote Visit www boighill com to request a quote...

Страница 11: ...06957 L 11 Flow Control Division Worcester Controls Visit www boighill com to request a quote Visit www boighill com to request a quote...

Страница 12: ...the information and specifications contained in this literature are believed to be accurate they are supplied for informative purposes only and should not be considered certified or as a guarantee of...

Отзывы: