background image

Flowline, Inc.  |  10500 Humbolt Street, Los Alamitos, CA 90720  

 p

 562.598.3015 

  f

 562.431.8507 

  w

 flowline.com

 

MN301340 Rev A2

 

 
 

 

 
 

 

 
 
 
 

 
 

 

 

Switch-Tek

 

Vertical Buoyancy Liquid Level Switch 

LV10 Series Manual

 

Содержание Switch-Tek LV10-1301

Страница 1: ...Flowline Inc 10500 Humbolt Street Los Alamitos CA 90720 p 562 598 3015 f 562 431 8507 w flowline com MN301340 Rev A2 Switch Tek Vertical Buoyancy Liquid Level Switch LV10 Series Manual ...

Страница 2: ...om of the baffle body such that the magnet does not influence the reed switch As the probe becomes immersed in liquid the float becomes buoyant and the magnet elevates causing the reed switch to change to change TABLE OF CONTENTS Specifications 3 Dimensions 3 Safety Precautions 4 Installation 5 Top Wall Installation 5 Bayonet Connection 5 Orientation 5 Connection to a Switch Car Kit LM30 series 6 ...

Страница 3: ... bar per C above 25 C Sensor Rating NEMA 6 IP68 Sensor Material Polypropylene PP Polyvinylidene Fluoride PVDF Cable Type 3 conductor 22 gauge shielded Cable Length 10 3m Cable Material PP or FEP jacket Mounting Threads 3 4 NPT 3 4 R CE Compliance EN 61326 EMC EN 61010 1 safety Switch Rating Reed Switch Rating Maximum Resistive Load VA Volts Amps AC Amps DC 15 0 50 0 3 0 21 15 120 0 13 0 09 15 240 ...

Страница 4: ...ene PP for the LV10 13_1 The switch is made of Polyvinylidene Fluoride PVDF and cable jacket is made of Fluorinated Ethylene Propylene FEP for the LV10 53_1 Make sure that the switch is compatible with the application liquids To determine the chemical compatibility between the sensor and its application liquids refer to the Compass Corrosion Guide available from Compass Publications Temperature an...

Страница 5: ...et adapter to interface to the LM30 series Switch Car For Switch Pak LM45 series installations use the 3 4 thread as the interface Bayonet Connection The thread can be removed to access the bayonet connection Simple press down on the threads and twist to release Orientation Mounting orientation bust be kept vertical for proper orientation The vertical buoyancy and float switches are orientated in ...

Страница 6: ...l length of the LV10 LM30 series assembly This will result in a lower activation point within the tank due to the added length It is recommended to remove the bayonet adapter when interfacing with Smart Trak First remove the bayonet adapter by pressing down twisting the adapter Next thread the sensor wire through the O ring and the sensor car and out through the hole between the sensor car shoe an...

Страница 7: ...nsor s cable Unwrap and discard the exposed foil shield from around the signal wires leaving the drain wire attached if desired With a 20 gauge wire striper remove the last 1 4 of the colored insulation from the signal wires SMART TRAK AND SWITCH PAK ASSEMBLIES The Vertical Buoyancy Level Switch can be packaged with Flowline Smart Trak or Switch Pak assembly Smart Trak with Compact Relay Controlle...

Страница 8: ..._1 switch can be wired normally open or normally closed for your application requires Normally Open Use the Black and White wire for operation the LV10 _3_1 in a normally open state Normally open is defined as the switch being open when the float is dry and closed when the float becomes submersed This operation is typical for indicating a high level Normally Closed Use the Black and Red wires for ...

Страница 9: ...f the sensor Do not use incompatible solvents which may damage the sensor s PP or PVDF plastic body Take particular care to remove any scaling from the float body and make sure that it moves freely 4 Sensor installation Follow the appropriate steps of installation as outlined in the Installation section of this manual TESTING THE INSTALLATION 1 Power Turn on power to the controller and or power su...

Страница 10: ...cedures outlined above 2 have been subjected to electrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel authorized by Flowline have attempted to repair 5 have been involved in accidents or natural disasters or 6 are damaged during return shipment to Flowline Flowline reserves the right to unilaterall...