MN300610 Rev C3
19
|
Advanced Features
Step Eight
This tool is designed to help solve operational issues. Changing these setting will alter the performance of
your unit. Please read through this HELP file to assist you in making adjustments or if still unclear about a
specific issue, please contact FLOWLINE, Applications Engineering.
NOTE:
When the Advanced Button is highlighted with a RED border, this indicates you have selected an
advanced feature.
Increase Output Filtering
: Placing a check mark in the box will increase the filtering (averaging) of the analog
output. Use this filter if the 4 to 20 mA output requires a smooth output for the application such as open channel
flow measurement.
Decrease Output Filtering
: Placing a check mark in the box will eliminate all filtering (averaging) of the
analog output. Enables a pulse by pulse level reading. Use this filter to see changes in level after every
sound pulse.
Note:
Never check increase output filtering and decrease output filtering at the same time.
Stabilize Output in Dead band
: Placing a check mark in the box will activate a filter to hold the output at Full
if the level enters the dead band of the EchoSonic
®
. This filter requires the level to leave the dead band at a
smooth and steady rate.