background image

®

OWNER’S MANUAL

50 Hz. Submersible Solids 
Handling Pumps

NOTICE D’UTILISATION

Pompes submersibles 50 Hz.
pour les matières solides

MANUAL DEL USUARIO

Bombas sumergibles 50 Hz. para 
el manejo de líquidos con sólidos

Installation/Operation/Parts

For further operating, installation, 
or maintenance assistance: 

Call 1-262-728-5551

English

 . . . . . . . . . . . . . .

Pages 2-6

Installation/Fonctionnement/Pièces

Pour plus de renseignements 
concernant l’utilisation,
l’installation ou l’entretien,

Composer le 1 (262) 728-5551

Français 

 . . . . . . . . . . .

Pages 7-11

Instalación/Operación/Piezas

Para mayor información sobre el 
funcionamiento, instalación o 
mantenimiento de la bomba:

Llame al 1-262-728-5551

Español

 . . . . . . . . . .

Paginas 12-16

P.O. Box 342, Delavan, WI 53115
Phone: 1-262-728-5551
Fax: 1-262-728-4461
E-Mail: [email protected]
Web Site: http://www.flotecwater.com

©1999, PRINTED IN U.S.A.

FPX185 (12/6/99)

XSE3200A SERIES

Water

is Our

Business

Содержание XSE3200A Series

Страница 1: ...2 6 Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 262 728 5551 Français Pages 7 11 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 262 728 5551 Español Paginas 12 16 P O Box 342 Delavan WI 53115 Phone 1 262 728 5551 Fax 1 262 728 4461 ...

Страница 2: ...tations or exclu sions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Flotec Limited Warranty FLOTEC P O Box 342 Delavan WI U S A 53115 Phone 1 262 728 5551 Fax 1 262 728 4461 E Mail flotec flotecpump com Web Site http www flotecwater com Safety 2 READ AND FOLLOW SAFETY INSTRUCTIONS This is the safety alert symbo...

Страница 3: ...arge line size pipe as follows A Pipe Size Of Will Handle a Flow Rate Of 38 mm 1 1 2 45 LPM 12 GPM 51 mm 2 79 LPM 21 GPM 63 mm 2 1 2 113 LPM 30 GPM 76 mm 3 181 LPM 48 GPM Use a 51 mm 2 swing check valve in pump discharge to prevent backflow of liquid into sump basin Check valve should be a free flow valve that will easily pass solids NOTICE For best performance of check valve when handling solids ...

Страница 4: ...des that apply Fuse or Circuit Dual Element Time Model H P Voltage Breaker Amps Delay Fuse Amps FPXSE3200A 4 10 220 240 15 10 OPERATION AND INSTALLATION NOTICE Do not allow pump to run in a dry sump It will void the warranty and may damage the pump An automatic overload protector in the motor will protect motor from burning out due to overheating overloading When motor cools down overload protecto...

Страница 5: ...er source for 30 minutes to allow motor to cool then reconnect to power source Check for cause of overheating overloading 1 Be sure all valves in discharge valve are fully open 2 Clean out discharge pipe and check valve 3 Check for blockage in pump inlet or impeller 4 Pump not sized properly A higher capacity pump may be required 1 Check switch or controller automatic floats for proper operation a...

Страница 6: ... Lower Volute 1 PW1 11P 2 Impeller 1 PW5 14P 3 Upper Volute 1 PW1 10PW 4 Power Cord 1 PS17 71 5 Volute Screws 4 U30 912PS 6 Double Lip Seal 1 U9 397 REPAIR PARTS LIST NOTE IF MOTOR FAILS REPLACE PUMP 1 2 5 6 3 Motor See Note 1477 0195 4 1478 0195 Automatic Float Switch ...