Troubleshooting

7

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

SYMPTOM

CORRECTIVE ACTION

Cleaner moves slowly 

Backwash and clean filter. Empty all baskets. 

or not at all.

Clear debris from oscillator or hose.
If hoses from skimmer to filter and back to pool are less than 1-1/2" diameter, replace with 1-1/2" hoses.
Pump in filtration system may be too small. Consult pool professional.
If your pool has a main drain (floor drain), close it during cleaner operation.

Cleans only perimeter 

Make sure vacuum regulator is installed.

of pool. 

Set ring brush adjuster to a higher number.

Cleaner hovers in one  

Hose is too short. It should be approximately 5-8’ longer than the full length of the pool. Buy an extension hose from 

area with hose fully

your dealer to give adequate length. 

extended.

Cleaner turns in  

Set brush ring adjuster to a lower number.

clockwise circles only  
and only covers one 
section of pool.

Oscillator run too fast. 

Make sure vacuum regulator is installed (the regulator marked “50” will slow it the most).
If your system has a return valve, gradually close it until oscillator runs at the desired speed.

Hose keeps coiling up.   For best results, when hose is not in use, store it flat and straight.

Lay hose out in the sun (flat and straight) for a few hours.
Hose is too long; remove 8’ section.

Pool not completely   

Any cleaner may miss a spot. Spot clean pool by attaching a Vac pole (telepole) to cleaner and steering it (see Page 5).

clean in four hours.

Try different brush ring adjuster settings (0-4) until the cleaner gives the desired results.
The cleaner was not designed to work under all solar covers.
Strong winds may interfere with complete cleaner coverage.

Cleaner flips on its side   This is normal if filter system develops a backpressure surge when the pump stops. The cleaner will right itself when  
when pump stops. 

system is restarted.

Hose comes loose 

Use reducer cone in skimmer.

when pump stops.

Cleaner sticks to pool 

Install diaphragm marked “50” in vacuum regulator.

bottom or pool main

Check inner brush ring for excessive wear.

drain.

Содержание FPPC-5000

Страница 1: ...800 365 6832 Fax 1 800 526 3757 E Mail info flotecwater com Web Site http www flotecwater com OWNER S MANUAL Automatic Pool Cleaner 3075 1097 FPPC 5000 Installation Operation Parts For further operati...

Страница 2: ...make all necessary repairs Also if there are stones roots etc under the liner remove them before installing the cleaner Before installing the cleaner clean your filter system Make sure you have cleane...

Страница 3: ...ave been subject to negligence abuse accident mis application tampering alteration nor due to improper installation operation maintenance or storage nor to other than normal application use or service...

Страница 4: ...ll reduce the cleaner s performance Reducer Cone Adapts hose to some skimmers Keeps hose in place in skimmer when pump stops Automatic Vacuum Regulator Hazardous suction Can trap or tear hair or body...

Страница 5: ...parts to pool cleaner STEP 4 Assemble Cleaner A Insert swivel assembly into cleaner body and twist 1 4 turn clockwise to lock B Set brush adjuster to 0 C Slide long hose cuff over swivel assembly to i...

Страница 6: ...skimmer or to suction port See below for various connections For best results With cleaner running and submerged pull hose to opposite end of pool and release STEP 7 Extend Hose Final Checks while cl...

Страница 7: ...or run too fast Make sure vacuum regulator is installed the regulator marked 50 will slow it the most If your system has a return valve gradually close it until oscillator runs at the desired speed Ho...

Страница 8: ...le Shaft 1 AT5102 Flow Director 1 AT5114 Replacement Hose Kit 1 each 20 8 and 4 Hose AT5816 20 Hose 1 AT5821 8 Hose 1 AT5811 4 Hose 1 AT5819 Not illustrated If body fails replace cleaner Optional Acce...

Страница 9: ...3757 Courriel info flotecwater com Site Web http www flotecwater com NOTICE D UTILISATION Nettoyeur automatique de piscine 3075 1097 FPPC 5000 Installation Fonctionnement Pi ces Pour de plus amples r...

Страница 10: ...e la recherche de dommages etc Si on remarque des dommages demander un professionnel qualifi en piscines de proc der aux r parations n cessaires De m me si on remarque la pr sence de pierres de racine...

Страница 11: ...d accident de modification ou d alt ration ni aux produits qui n ont pas t install s utilis s entrepos s ou entretenus correctement ni ceux qui n ont pas t utilis s ou entretenus normalement y compri...

Страница 12: ...ermet de brancher le tuyau sur certaines cu moires Laisser le tuyau branch dans l cumoire lorsque la pompe s arr te R gulateur de d pression Aspiration dangereuse Peut pi ger et d chirer les cheveux o...

Страница 13: ...e pouce droite pour le verrouiller B R gler le r gleur de la brosse sur 0 C Brancher le tuyau en glissant son grand manchon par dessus l embout oscillant 5 o Immerger le nettoyeur A D marrer la pompe...

Страница 14: ...t oppos de la piscine puis le rel cher 7 Allonger le tuyau Derni res v rifications Pendant que le nettoyeur fonctionne Water Level Vacuum Regulator Elbow User Supplied Reducer Cone Skimmer Branchemen...

Страница 15: ...assurer qu un r gulateur de d pression est pos le r gulateur rep r 50 le ralentira le plus trop vite Si le syst me comporte un robinet de retour le fermer graduellement jusqu ce que l oscillateur tour...

Страница 16: ...e 2 44 m tres 8 pieds et un de 1 22 m tre 4 pieds AT5816 Tuyau de 6 10 m tres 20 pieds 1 AT5821 Tuyau de 2 44 m tres 8 pieds 1 AT5811 Tuyau de 1 22 m tre 4 pieds 1 AT5819 Pi ces non illustr es Si le c...

Страница 17: ...3757 E Mail info flotecwater com Internet http www flotecwater com MANUAL DEL PROPIETARIO Limpiador autom tico para piscinas 3075 1097 FPPC 5000 Instalaci n Operaci n Piezas Para obtener asistencia a...

Страница 18: ...ce todas las reparaciones necesarias Adem s si hay piedras ra ces etc debajo del revestimiento s quelas antes de instalar el limpiador Antes de instalar el limpiador limpie el sistema de filtraci n Ve...

Страница 19: ...EC hayan sido objeto de negligencia abuso accidente aplicaciones contraindicadas manejo indebido alteraciones ni debido a instalaci n funcionamiento mantenimiento o almacenaje incorrectos ni a ninguna...

Страница 20: ...madores Mantiene la manguera en posici n en el espumador cuando se detiene la bomba Regulador autom tico de aspiraci n Aspiraci n peligrosa Puede atra par o arrancar el cabello o desgarrar las partes...

Страница 21: ...hacia la derecha para trabarla B Coloque el regulador del cepillo en 0 C Deslice el pu o de la manguera larga por encima de la unidad oscilante para instalar la manguera PASO 5 Sumerja el Limpiador A...

Страница 22: ...la piscina y su ltela PASO 7 Extienda la Manguera Verificaciones finales mientras el limpiador est funcionando Water Level Vacuum Regulator Elbow User Supplied Reducer Cone Skimmer Conexiones de la ma...

Страница 23: ...regulador de aspiraci n el regulador marcado 50 lo enlentecer al m ximo demasiado r pido Si su sistema tiene una v lvula de retorno ci rrela gradualmente hasta que el oscilador marche a la velocidad d...

Страница 24: ...de 20 8 y 4 AT5816 Manguera de 20 pies 1 AT5821 Manguera de 8 pies 1 AT5811 Manguera de 4 pies 1 AT5819 No se ilustra Si el cuerpo falla reemplace el limpiador Optional Accessories Unidapt Handle No A...

Отзывы: