14
GB
Troubleshooting
Faults
Causes
Remedies
Pump does not start
Mains voltage is not applied
Check mains voltage
Float switch (
7) does not
switch
Bring float switch into higher
position
Pumps has no dis-
charge
Buckled pressure hose
Repair point at which the line
is bent
Trapped air in the pump cas
-
ing
Tip the pump underwater until
the air escapes
Pump does not switch
off
Float switch (
7) cannot
drop
Set up pumps correctly on the
pit base
Flow rate insufficient
Reduces pump performance,
through severely contami-
nated water and additions in
the water which produce a
grinding effect
Clean pumps and replace
wear parts
Pump switches off after
a short period
Motor contactor disconnects
the pumps because of water
pollution that is too severe.
Pull out power plug and clean
the pump as well as shaft
Water temperature too high,
motor contactor breaks
Note maximum water tem-
perature of 35 °C!
Replacement parts/Accessories
Spare parts and accessories can be obtained at
www.grizzly-service.eu
If you do not have internet access, please contact the Service Centre via telephone (see
“Service-Center” Page 13). Please have the order number mentioned below ready.
Item Description
Product No.
4
Floor plate 91103470
4a
Screw set for
floor plate
91103471
9/10
Connector set (reducer, sealing ring, angle adapter)
91103472
11
8 m nylon cord
91103473
Содержание FTS 1100 C3