background image

EN

 
 

Kits – FS34H90 & FS34H
Leak Detection & Automatic Water Shut-off System

Installation and Operating Manual

 

Congratulations on your purchase of a Floodstop electronic water leak detection and automatic water shut-off kit 
for washing machines. This product has been designed to give you years of reliable service and minimize home 
water damage by detecting water leaks and automatically shutting off the water supply.

To ensure proper installation and to maximize the performance of your Floodstop water leak detection system, 
please read this manual thoroughly.

PLEASE READ CAREFULLY BEFORE PROCEEDING:

 If a leak is detected, the Floodstop Valves will shut off the water 

going to the washing machine. This will stop the continuous flow of water from the water supply valve to the 
washing machine. However, all or some of the water that is already in the washing machine and hoses may still 
leak out onto the floor.

NOTE: 

This unit was shipped with an installation and operating manual that contains important information about 

its operation. If you are installing this unit for use by others, we recommend you leave this manual – or a copy of 
it – with the user.

Washing Machine Kit

FEATURES:

•  Control Panel has easy to read, lighted function buttons
•  AC Power with battery backup – For continued operation in the event of power outages
•  Solid brass, full port motorized ball valves for dependable, long lasting performance
•  Valves automatically shut-off the water supply when a leak is detected
•  Automatic monthly maintenance cycling of the valves to ensure reliable operation
•  Valves can be opened and closed with the touch of a button
•  Activates an audible alarm when a leak is detected
•  Mute button to silence the audible alarm
•  Can be reset and reused continuously with the touch of a button
•  Can be tested at any time with the touch of a button
•  Can accommodate additional water leak sensors
•  1 Year Limited Warranty

This Package Contains:

A  (2) Floodstop Motorized Brass 

Valves (3/4” FHT x 3/4” MHT)

B  (1) Control Panel
C  (1) Leak Sensor with Paper Sleeve
D  (1) AC Adaptor
E  (1) Wire Harness
F  (1) Hook & Loop Mounting Pad
G  (2) Mounting Screws with Anchors
H  (1) Pigtail

Check to make sure everything in the package 
matches the Contents Listing above. Read the 
instructions thoroughly before installing or 
operating the Floodstop system.

Warning: 

Do not put finger(s) inside Floodstop 

Valves. Risk of serious injury may occur. Caution: 
Do not grip plastic motor drive for leverage when 
tightening Floodstop Valves.

STOP: Read the instructions thoroughly before installing or operating the Floodstop System. The Floodstop 
Valves get installed directly to your existing valves. If you are not sure how to install the Floodstop Valves to 
your existing water lines, we recommend that you contact a licensed Plumber.

WARNING:

•  For use with water only.
•  Do not install on gas line.

Installation

1.  Shut off the hot and cold valves that supply water to your 

washing machine.

 
2.  Remove the hot and cold washing machine hoses from 

both valves. Mark the hoses so you know which hose goes 
to which valve.

 NOTE: 

Do not remove hoses from washing 

machine.

3.  Your existing hot and cold manual shut-off valves will have 

outlets that either face you, or face downward.

A. 

If the outlets face you: 

Hand tighten the Floodstop 

Valves to the manual shut-off valves so their outlets point 
downward as shown in the diagram. Note that a washer 
has been pre-assembled in each coupling nut.

B. 

If the outlets face downward: 

Hand tighten the Floodstop 

Valves to the manual shut-off valves so their outlets point 
sideways as shown in the diagram. Note that a washer 
has been pre-assembled in each coupling nut.

4.  Hand tighten the hot and cold washing machine hoses to the 

correct Floodstop Valve.

5.  Lightly wrench tighten all connections 1/4 turn, or until snug. 

Do not over tighten.

6.  Turn on the hot and cold manual shut-off valves and check 

for leaks.

7.  Mount the Floodstop Control Panel in an easily accessible 

location within 30 inches of the Floodstop Valves. You may 
mount the panel using the screws and anchors, or Hook & Loop 
Mounting Pad provided. When using the Hook & Loop Mounting 
Pad, make sure the adhesive is put on a clean, dry surface. 

NOTE:

 Depending on the location you pick, and the distance 

between the hot and cold shut-off valves, you may need to 
purchase two (2) Floodstop Control Panel to Valve Extension 
Wires, Model #FSACEXT9 (available where you purchased your 
Floodstop System).

8.  With the contacts of the wire harness connector facing you, plug 

the 6-pin connector end of the Wire Harness into the bottom of 
the Control Panel.

1

4

5

6

7

(NO) Output &
Sensitivity Adj

6 pin connector

8

valve

3A

valve

3B

2

A

B

C

D

E

H

F

G

   

Содержание FS34H90

Страница 1: ...the instructions thoroughly before installing or operating the Floodstop system Warning Do not put finger s inside Floodstop Valves Risk of serious injury may occur Caution Do not grip plastic motor drive for leverage when tightening Floodstop Valves STOP Read the instructions thoroughly before installing or operating the Floodstop System The Floodstop Valves get installed directly to your existin...

Страница 2: ... sweating causing high humidity Correct the problem by placing the Paper Sleeve on the Leak Sensor or use a paper towel as a barrier Only one Floodstop Valve operates Unplug 6 pin connector from Control Panel and reconnect Locate plug connection between Control Panel and the Floodstop Valve that does not operate Unplug the connection and reconnect making sure arrows on side of plugs line up Push t...

Страница 3: ...de producirse un riesgo de lesiones graves Precaución No sujete el accionamiento del motor de plástico para hacer palanca cuando apriete las válvulas Floodstop ATENCIÓN Lea detenidamente las instrucciones antes de instalar o poner en funcionamiento el sistema Floodstop Las válvulas Floodstop se instalan directamente en las válvulas existentes Si no está seguro de cómo instalar las válvulas Floodst...

Страница 4: ...unciona una válvula Floodstop Desenchufe el conector de 6 pines del panel de control y vuelva a conectarlo Localice la conexión entre el panel de control y la válvula Floodstop que no funciona Desenchufe la conexión y vuelva a conectarla asegurándose de que las flechas de los lados de los enchufes estén alineadas Pulse el botón Close Cerrar y espere unos segundos A continuación pulse el botón Open...

Страница 5: ... utiliser le système Floodstop Avertissement N insérez jamais un doigt à l intérieur des soupapes Floodstop Cela risque de causer des blessures graves Mise en garde évitez de tenir le moteur d entraînement pour obtenir un effet de levier lorsque vous serrez les soupapes Floodstop ARRÊT Lisez attentivement les instructions avant d installer ou d utiliser le système Floodstop Les soupapes Floodstop ...

Страница 6: ... a paper towel as a barrier Une seule soupape Floodstop fonctionne Débranchez le connecteur à 6 broches du panneau de commande et rebranchez le Repérez le raccord entre le panneau de commande et la soupape Floodstop défectueuse Débranchez le raccord et reconnectez le en vous assurant que les flèches sur le côté des prises sont alignées Appuyez sur le bouton Fermer et attendez quelques secondes App...

Отзывы: