2.4.5
Quadrature Pulse Output
Quadrature Pulse Outputs may be wired directly to any flow instruments that accept
quadrature signals for signal integrity verification (custody transfer applications) or for bi-
directional flow.
2.5
Meter Calibration Factor (K-Factor, Scale Factor)
Each flowmeter is individually calibrated and supplied with a calibration certificate
showing the number of pulses per unit volume
(e.g. pulses/Litre)
which is characteristic to
individual outputs on your meter. Meters fitted with integral instruments will have the
relevant K-factor entered into the program of the instrument at the factory.
2.6
Integral Instruments
If your flowmeter was purchased with an integral Rate Totaliser then the instrument will
be factory wired for reed switch input into the instrument. If your flowmeter is fitted with
an integral Batch Controller, the NPN
(open collector)
output from the Hall Sensor is factory
wired and programmed. If you are unsure of the factory wiring of your instrument, remove
the instrument bezel to check the wiring.
Unless programming details were provided at time of order, the instrument program will
contain factory default parameters. Integral instruments will be programmed with the
relevant K-factor for the meter, however all output(s) are turned OFF, and if required need
to be turned ON and then configured to suit the application requirements.
90°
phase shift
between
Quadrature
Pulse
Output
V (dc)
Common -0V
2
1
REED
V
QUAD
NPN HALL EFFECT