Supply
Torque Output (
lbf-in
/ Nm)
880
/ 100
1770
/ 200
12VAC
-
12VDC
Current Draw (Start / Run / LRA)
7.2A / 5.2A / 17.8A
7.2A / 5.2A / 17.8A
Speed (90°) DC, seconds
14
28
Motor - 12vdc Perm Magnet Brush Type
25W
25W
Duty Cycle (on/off / mod)
75%
75%
Motor Starts, per hour, Max
1200
1200
Motor Protection, Temp / Class
135°C / Class F
135°C / Class F
24VAC
-
24VDC
Current Draw (Start / Run / LRA)
4.2A / 3.2A / 11A
4.2A / 3.2A / 11A
Speed (90°) DC, seconds
14
28
Motor - 24vdc Perm Magnet Brush Type
25W
25W
Duty Cycle (on/off / mod)
75%
75%
Motor Starts, per hour, Max
1200
1200
Motor Protection, Temp / Class
135°C / Class F
135°C / Class F
120V
Current Draw (Start / Run / LRA)
1.16A / 0.93A / 1.47A
1.16A / 0.93A / 1.47A
Speed (90°) 60Hz / 50Hz, seconds
16 / 19
33 / 39
Motor - 120vac Split-Phase Cap TENV
40W
40W
Duty Cycle (on/off / mod)
25% / 75%
25% / 75%
Motor Starts, per hour, Max
1200
1200
Motor Protection, Temp / Class
135°C / Class F
135°C / Class F
230V
Current Draw (Start / Run / LRA)
0.54A / 0.42A / 0.66A
0.54A / 0.42A / 0.66A
Speed (90°) 60Hz / 50Hz, seconds
16 / 19
33 / 39
Motor - 230vac Split-Phase Cap TENV
40W
40W
Duty Cycle (on/off / mod)
25% / 75%
25% / 75%
Motor Starts, per hour, Max
1200
1200
Motor Protection, Temp / Class
135°C / Class F
135°C / Class F
All
Environmental Rating
NEMA 4/4X/IP67
Electrical Entry (2)
3/4" EMT or ABS gland
Control
On/Off or Proportional
Ambient Operating Range
-22°F to +158°F / -30°C to +70°C
Humidity Range
0-95% RH
Altitude Limit
9850 ft / 3000 m
Below are Terms and Definitions used throughout this manual.
1 . XTS/TS
product manufactured without/with Torque Switches.
2 . XFS/FS
product manufactured without/with Fail Safe built-in.
3 . LCS
is an industry acronym for a Local Control Station.
CONVENTIONS USED IN THIS MANUAL
Use this table to efficiently select the actuator and wiring diagram you require.
Control
Voltage
Torque Switches
Fail Safe
Local Control Station
IOM
Wiring Diagram Page
On/Off
12VDC/VAC
XTS/TS
XFS
None
This IOM
Proportional
12VDC/VAC
XTS/TS
XFS
None
This IOM
On/Off
24VDC/VAC
XTS/TS
XFS
None
This IOM
Proportional
24VDC/VAC
XTS/TS
XFS
None
This IOM
On/Off
120VAC
XTS/TS
XFS
None
This IOM
Proportional
120VAC
XTS/TS
XFS
None
This IOM
On/Off
230VAC
XTS/TS
XFS
None
This IOM
Proportional
230VAC
XTS/TS
XFS
None
This IOM
On/Off / Proportional
24VDC/VAC
XTS/TS
FS
None
HRSN3FSIOM
reference correct IOM
On/Off / Proportional
120-230VAC
XTS/TS
FS
None
HRSN3FSIOM
On/Off / Proportional*
24VDC/VAC
XTS/TS
XFS
LCS
HRCK3IOM
On/Off / Proportional
120-230VAC
XTS/TS
XFS
LCS
HRCK3IOM
ACTUATOR OPTIONS
ACTUATOR SPECIFICATIONS
Elo-NA8
Elo-NB9
* No 24VDC/VAC can be equipped with HRCL/CD options
TECHNICAL INFORMATION
USE ONLY FLO-TITE GENUINE REPLACEMENT PARTS
ELo Rev C ECR 044V
Page
4
of 28