23.4
Save options & storage
•
Inspection route
4
: This setting is used to activate and configure the Inspection Route
function. For more information, see section 18
•
Preview image before saving
: This setting defines if a preview image will be displayed
before the image is saved.
•
Add annotation after saving
: This setting defines if an annotation tool will be displayed
when the image has been saved. Available options are:
◦
Save
: No annotation tool will be displayed.
◦
Save & add note
: The note annotation tool will be displayed.
◦
Save & add table
: The table annotation tool will be displayed.
◦
Save & add voice annotation
: The voice annotation tool will be displayed.
◦
Save & add sketch
: The sketch annotation tool will be displayed.
◦
Save & add any annotation
: The annotation tool menu will be displayed.
•
Image resolution
: This setting defines the resolution of the images captured by the
camera. Available options are
Normal
and
UltraMax
5
. For more information, see sec-
tion 8.1.4
.
•
Video compression
: This setting defines the storage format for video clips. Available
options are:
◦
Mpeg (*.mpeg)
: MPEG recordings cannot be edited after the file has been saved.
◦
Radiometric storage (*.csq)
: A CSQ file supports full radiometry but is only sup-
ported by FLIR Systems software. The file does not include any visual image infor-
mation. With this setting, only the image modes
Thermal
and
Macro
are supported
when recording video.
•
Video frame rate
: This setting is used to select the frame rate for video recordings.
•
Photo as separate JPEG
: For the
Thermal MSX
,
Thermal
, and
Picture in picture
im-
age modes, a visual image is always saved in the same JPEG file as the thermal im-
age. Enabling this setting saves an extra low-resolution visual image as a separate
JPEG file.
•
Digital camera
: This setting is used to turn on/off the digital camera. Turning off the
digital camera can for example be required in restricted areas and in confidential (e.g.
doctor/patient) situations. When the digital camera is off, the images modes
Thermal
MSX
and
Picture in picture
are disabled.
•
Measure distance
: This setting defines if the laser distance meter will be used to
measure the distance when an image is saved. With this setting, the
Object distance
parameter (see section 13.5
Changing the measurement parameters
) in the image
data is automatically updated with the measured distance when an image is saved.
(There is no effect on the
Object distance
setting in live mode.)
•
File naming format
: This setting defines the naming format for new image/video files.
The setting has no impact on already saved files in the archive. Available options are:
◦
DCF
: DCF (Design rule for Camera File system) is a standard that specifies the
naming method of image files (and much more). With this setting, the name of a
saved image/video file will be FLIRxxxx, where xxxx is an incremental counter. Ex-
ample: FLIR0001. (When the counter has reached 9999, the file name will change
to IR_yyyyy.jpg.)
◦
Date prefix
: A prefix will be added to the filename, including the date and the text
“IR_” for images and “MOV_” for videos. Examples: IR_2015-04-22_0002 and
MOV_2015-04-22_0003. The date format will follow the
Date & time format
setting,
see section 23.5
◦
Date + time only
: The filename will only include the date and time of capture
(YYYYMMDDhhmmssfff).
Note
With the
Date prefix
and
Date + time only
settings, the files may not automati-
cally be detected by third-party applications.
#T810253; r. AL/84068/84441; en-US
92
4. This item is dependent on the camera model.
5. Not supported when using macro.