427-0033-00-12 Version 110
February 2019
53
This document does not contain any export-controlled information.
Advanced Configuration
When the alarm source is Video Analytics the
Alarm ID
corresponds to the area or tripwire (1-8), as configured in the
Setup menu. The
Alarm ID
is set sequentially during the
setup for each alarm source. Refer to
.
Alarm Actions:
Just as there can be multiple sources of
alarms, there are also a variety of actions or responses to
these alarms. Some actions are only used with pan/tilt
cameras. Actions such as Point, Load ScanList, Go To
Preset, and Engage Radar Track would only be used with a
pan/tilt camera and are not used with the F
-
Series ID fixed
camera.
For the F
-
Series ID, typically a rule will be configured to
Send a Notification
,
Capture an Image
, or
Arm/Disarm
Analytics
. If more than one action is needed, it is necessary
to configure multiple rules. Examples of these actions are
provided below.
When the Alarm Action is set to
Send Notification
, a
Notification List must be selected. The
Send Notification
action uses a Msg System and a Notification List that are set
up in the Services menu (refer to
).
To attach a snapshot, select the option
All Non Radiometric
to send a normal JPEG image from the
Attach Image File
pull down list.
Radiometric
(a special type of JPEG with
temperature data) is not available on the F
-
Series ID
camera.
Each rule that sends a notification also has the option to
send an activity report to the same notification list every 6,
12, or 24 hours. The activity report indicates whether or not
an alarm was triggered during the specified time period.
Note that this can be selected on a rule by rule basis.