5.1 General cabling guidance
Cable types and length
It is important to use cables of the appropriate type
and length
• Unless otherwise stated use only standard cables
of the correct type, supplied by Raymarine.
• Ensure that any non-Raymarine cables are of the
correct quality and gauge. For example, longer
power cable runs may require larger wire gauges
to minimize voltage drop along the run.
Routing cables
Cables must be routed correctly, to maximize
performance and prolong cable life.
• Do NOT bend cables excessively. Wherever
possible, ensure a minimum bend diameter of 200
mm (8 in) / minimum bend radius of 100 mm (4 in).
• Protect all cables from physical damage and
exposure to heat. Use trunking or conduit where
possible. Do NOT run cables through bilges or
doorways, or close to moving or hot objects.
• Secure cables in place using tie-wraps or lacing
twine. Coil any extra cable and tie it out of the way.
• Where a cable passes through an exposed
bulkhead or deckhead, use a suitable watertight
feed-through.
• Do NOT run cables near to engines or luorescent
lights.
Always route data cables as far away as possible
from:
• other equipment and cables,
• high current carrying AC and DC power lines,
• antennae.
Strain relief
Ensure adequate strain relief is provided. Protect
connectors from strain and ensure they will not pull
out under extreme sea conditions.
Cable shielding
Ensure that the cable is properly shielded that the
cable shielding is intact (e.g. hasn’t been scraped off
by being squeezed through a tight area).
5.2 Connections overview
Dragonly-4
,
Dragonly-5
,
Dragonly-7 Pro
,
Wi-Fish
™
products and the
CPT-DV
and
CPT-DVS
include connectors with a 3 keyway guide.
Depending on date of manufacture
Dragonly 6
,
Dragonly 7
products and
CPT-60
/
CPT-70
/
CPT-80
transducers are available with 1 keyway guide
(Legacy) or 3 keyway guide (Updated). Adaptor
cables can be used to connect 1 keyway connectors
to 3 keyway connectors.
Rear connector / Locking collar
Connector
Description
Unit /
Display
Compatible
transducer
Red – 1
keyway
• Legacy
Dragonly
6
• Legacy
Dragonly
7
• Legacy
CPT-60
• Legacy
CPT-70
• Legacy
CPT-80
Green – 3
keyway
•
DVS
•
Pro
• Updated
Dragonly
6
• Updated
Dragonly
7
•
CPT-DVS
• Updated
CPT-60
• Updated
CPT-70
• Updated
CPT-80
Yellow – 3
keyway
•
DV
•
Wi-Fish
™
•
CPT-DV
Black – 3
keyway
•
5 M
• N/A –
5
M
power
connector
36
Dragonly–4 / Dragonly–5 / Dragonly–7 / Wi–Fish
Содержание E70290
Страница 2: ......
Страница 4: ......
Страница 12: ...12 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Страница 18: ...18 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Страница 34: ...34 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Страница 42: ...42 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Страница 108: ...108 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Страница 112: ...112 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Страница 122: ...122 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Страница 126: ...126 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Страница 132: ...132 Dragonly 4 Dragonly 5 Dragonly 7 Wi Fish ...
Страница 133: ...Chapter 16 Spares and accessories Chapter contents 16 1 Spares Accessories on page 134 Spares and accessories 133 ...
Страница 135: ......