5 Blackfly S Physical Interface
5.9
Case Temperature and Heat Dissipation
You must provide sufficient heat dissipation to control the internal operating temperature of the camera.
The camera is equipped with an on-board temperature sensor.
n
For cased models—It allows you to obtain the temperature of the camera board-level components. The sensor
measures the ambient temperature within the case.
n
For board-level models—It allows you to obtain the temperature of the camera FPGA junction temperature. The
temperature must be kept under 100°C. Some models may not require heat sinking depending on the mode of
operation.
As a result of packing the camera electronics into a small space, the camera can become hot to the touch
when running. For cased models, this is expected behavior and will not damage the camera electronics. For
board-level models, the temperature must be kept under 100°C and therefore may require a heat sink to
avoid damage.
To reduce heat, use a cooling fan to set up a positive air flow around the camera, taking into consideration the following
precautions:
n
Mount the camera on a heat sink, such as a camera mounting bracket, made out of a heat-conductive material
like aluminum. When designing a heat sink for a board-level model, respect the
n
Make sure the flow of heat from the camera to the bracket is not blocked by a non-conductive material like
plastic.
n
Make sure the camera has enough open space around it to facilitate the free flow of air.
To access temperature information:
n
Query the GenICam Device Control feature DeviceTemperature.
For board-level models—Device temperature can be monitored in SpinView as follows:
n
Select
Device_Temperature_Selector
Enum Node
n
Set
Device_Temperature_Selector
Enum Node Value
to
Mainboard
n
Read
Device_Temperature Node
2/19/2019
©2015-2019 FLIR
Integrated Imaging
Solutions Inc.
All rights reserved.
FLIR Blackfly
®
S Installation Guide
27