FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
96
of
170
Digital outputs
Digital outputs can be programed as free setpoints and used for different functions as shown below. The
output(s) can be set as threshold or window additional to the well-known basic output at free programmable
setpoints. Refer to SmartAPP applications in this manual for digital output functions of selected application.
S AIN Free setpoint of absolute indicated weight
The status of the digital output changes with comparing the set point value and absolute indicated weight
value as shown below.
Example:
If SP1
SP1
LOW
SP1
HIGH
= 100 kg or
= 100 kg and
= 150 kg.
BAS-HI
Basic, active high
Output is high if absolute indicated
weight is heavier than setpoint.
(Default)
BAS-LO
Basic, active low
Output is low if absolute indicated
weight is heavier than setpoint.
THR-HI
Threshold, active high
Output goes to high if absolute indicated
weight is heavier than setpoint high.
Returns the low if the weight is less than
setpoint low.
THR-LOW
Threshold, active low
Output goes to low if absolute indicated
weight is heavier than setpoint high.
Returns the high if the weight is less
than setpoint low.
VIN-HI
Window, active high
Output goes to high if absolute indicated
weight is between setpoint high and
setpoint low.
VIN-LOW
Window, active low
Output goes to low if absolute indicated
weight is between setpoint high and
setpoint low.