FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
83
of
170
10.2.1 Product Limit values at Checkweighing
The entry type can be selected as a weight value, deviation from target or percentage of the target,
parameter 312. This selectio
n defines the set values’ entry names as shown below;
Entry type
Target
Low limit
High limit
Unloaded
scale limit
Value
TARGET
LOW
HIGH
EMPTY
Deviation
TARGET
-TOL
+TOL
EMPTY
Percent %
TARGET
-TOL
+TOL
EMPTY
The target (nominal value), low, high and empty range entries should be entered the weight value in unit;
Tolerance entries should be entered as deviation from nominal weight in unit or in percentage.
The descriptions below are considered the value entry type. Follow the similar way for entry types deviation or
percentage.
The nominal and limit values entry
1. Press the
key.
2. The current target value appears on the display as [ TARGET 1250 kg ]. Enter the new value with
numerical keys. Press the
key to save it or press
key to return operation without saving.
3. The [ LOW : 1245.6 ] prompt will show the current low tolerance. Enter new value with numerical
keys. Press the
key to save it or press
key to return operation without saving.
4. The [ HIGH : 1255.6 ] prompt will show the current high tolerance. Enter new value with numerical
keys. Press the
key to save it or press
key to return operation without saving.
5. The [ EMPTY : 100 ] prompt indicates the current empty range of the platform. Enter new value
with numerical keys.
6. Press the
key to return the operation after saving the entry or press
key to return operation
without saving.
Product record into SET memory
1. Press
key for more than 2 seconds. [ MEMORY ] prompt appears.
2. Press
key. The last used Set memory code appears [ SET :001 ].
3. Enter the new memory code by pressing the numerical keys and press
key.
4. The target value appears on the display as [ SET 001: TARGET ], [ 1250 kg ]. Enter the new target
with numerical keys and press the
key.
5. The low tolerance prompt [ LOW : 1245.6 ] appears. Enter new value with numerical keys and press
the
key.
6. The high tolerance prompt [ HIGH : 1255.6 ] appears. Enter new value with numerical keys and
press the
key.
7. The [ EMPTY : 100,0 ] prompt appears on the display. Enter new value with numerical keys.
8. Press the
key to enter the following memory after saving it or press
key to return operation
without saving.
Select product from SET memory
1. Press
key. The current target value appears on the display as [ TARGET: 1250 kg ].
2. Press
key for more than 2 seconds to enter Set memory. The last used Set memory code
appears on the display as [ SET :001 ].
3. Enter the memory code of the product by pressing the numerical keys and press
key.
4. The selected product limits are loaded for usage after displaying values.
5. Or press
key to exit without selecting the product from memory.