background image

FLINflex 

FLIN solar GmbH - Christianspries 30, 24159 Kiel 

+49 0431 60109038 [email protected]

 

 

 

 
 

 
 
 

EN 

When selecting the charge controller, observe the technical data of the FLINflex and the charge 
controller. Compatible charge controllers are listed in the table below. You can also purchase them 
via the FLIN solar website. 

The choice of the MPPT solar charge controller depends on your on-board voltage and the size of 
the FLINflex. We are happy to offer you the appropriate charge controller along with the FLINflex. 

 

MPPT-Solar-Charge Controller 

FLINflex 

12 V 

24 V 

48 V 

FLINflex 50 W 

Western WMarine 10 

Western WMarine 10 

Genasun GVB-8 48V 

FLINflex 100 W 

Western WMarine 10 

Western WMarine 10 

Genasun GVB-8 48V 

FLINflex 150 W 

Western WMarine 10 

Genasun GVB-8 48V 

FLINflex 200 W 

Victron Energy 75/15 

Western WMarine 10 

Genasun GVB-8 48V 

FLINflex 250 W 

Victron Energy 100/20 

Victron Energy 75/15 

Genasun GVB-8 48V 

FLINflex 300 W 

Victron Energy 100/20 

Victron Energy 75/15 

Genasun GVB-8 48V 

FLINflex 350 W 

Victron Energy 100/30 

Victron Energy 75/15 

Genasun GVB-8 48V 

FLINflex 400 W 

Victron Energy 100/30 

Victron Energy 75/15 

FLINflex 450 W 

Victron Energy 100/30 

Victron Energy 75/15 

FLINflex 500 W 

Victron Energy 100/50  Victron Energy 100/20 

FLINflex 550 W 

Victron Energy 100/50  Victron Energy 100/20 

FLINflex 600 W 

Victron Energy 100/50  Victron Energy 100/30  Victron Energy 100/20 

 

The MPPT solar charge controllers from Victron Energy and Genasun feature very fast maximum 
power point tracking, so they fully exploit the performance of the FLINflex in all weather conditions. 
Victron Energy's charge controllers feature a Bluetooth interface to monitor the FLINflex charging 
performance via smartphone. The app helps to find the optimal orientation of the FLINflex so that it 
delivers maximum power at any time of day. 

When connecting the FLINflex to the charge controller, the cables can be laid flying through the 
companionway or a hatch. For regular use of the FLINflex, fixed cabling with deck feed-through via 
connector at the mast base is recommended. 

CAUTION: Too much line tension can cause damage to components such as the eyelets, lines, 
modules or carabiners. As soon as the system is electrically connected to the on-board network 
through the plugs, the generated energy is fed into the on-board network. 

 
 

 

 

Содержание FLINflex 50W

Страница 1: ...FLINflex FLIN solar GmbH Christianspries 30 24159 Kiel 49 0431 60109038 info flin solar de EN OPERATING AND SAFETY INSTRUCTIONS 1 DE BEDIENUNGSANLEITUNG UND SICHERHEITSHINWEISE 13 ...

Страница 2: ...INflex You can now efficiently convert and use the sun s energy for yourself without noise emissions independently of the power grid in remote locations at anchor or while driving your electric motor Please read the user manual and safety instructions carefully before using the product Follow the listed instructions and advice to get the optimal use out of your FLINflex Best regards Your FLIN Team...

Страница 3: ...3 4 Technical data of the system 4 5 Storage of the FLINflex 6 6 Variants 6 6 1 Mounting systems 6 6 2 Cables 7 7 Setup 7 7 1 FLINflex standard 7 7 2 FLINflex snap 7 7 3 FLINflex eyelet 8 7 4 FLINflex tex 8 7 5 FLINflex magnetic 8 8 Connection to the on board power supply 8 9 Debugging 10 10 Safety instructions 11 11 Important notes of disposal 12 12 Declaration of comformity 12 ...

Страница 4: ...Nflex Instruction manual 2 Additionally needed MPPT controller matched to the power of the FLINflex and to your on board power system Connection from the controller to the FLINflex Deck feedthrough or MC4 extension cable Connection from controller to battery 3 Product variants FLINflex 50W FLINflex 100W FLINflex Custom ...

Страница 5: ...ype MC4 Weight 830g Power 50W Power bifacial 60W VOC 6 4V 12 8V 6 4V 12 8V ISC 9 7A 4 85A 9 7A 4 85A ISC Bifacial 10 67A 5 345A VMPP 5 6V 11 2V 5 6V 11 2V IMPP 8 9A 4 45A 8 9A 4 45A IMPP Bifacial 10 62A 5 31A Protection class IP67 There is an additional possibility to manufacture a customized solar panel The parameters may differ depending on the configuration Note The data listed are guide values...

Страница 6: ...1450g Power 100W Power bifacial 120W VOC 12 9V 25 8V 12 9V 25 8V ISC 9 7A 4 85A 9 7A 4 85A ISC Bifacial 10 67A 5 345A VMPP 11 3V 22 6V 11 3V 22 6V IMPP 8 9A 4 45A 8 9A 4 45A IMPP Bifacial 10 62A 5 31A Protection class IP67 There is an additional possibility to manufacture a customized solar panel The parameters may differ depending on the configuration Note The data listed are guide values which a...

Страница 7: ...e appropriate size Dimensions 680mm x 565mm x 100mm 1150mm x 550mm x 130mm 6 Variants The FLINflex series is highly customizable due to its different mounting systems and cable variants Depending on the application the appropriate configuration can be selected 6 1 Mounting systems We have designed many different innovative mounting systems to make it possible to use solar energy at almost any poin...

Страница 8: ... can be connected in series FLIN solar panels of different sizes can also be combined A wiring example can be found in the in the download section of our website 7 1 FLINflex standard The FLINflex standard has no further fastening options For example it can be screwed to the deck via the approx 25mm wide edge or used flying It is important to note that a minimum distance of 10mm to the solar cell ...

Страница 9: ...tex can be mounted and dismounted very quickly 7 5 FLINflex magnetic Due to the magnetic foil on the back of the solar panel the FLINflex magnetic finds a hold on any steel or iron based metal surface For example it can be fixed to the car door or on the roof when camping depending on the position of the sun For an independent power supply the surfaces of a container can be equipped if necessary w...

Страница 10: ...B 8 48V FLINflex 400W Victron Energy 100 30 Victron Energy 75 15 FLINflex 450W Victron Energy 100 30 Victron Energy 75 15 FLINflex 500W Victron Energy 100 50 Victron Energy 100 20 FLINflex 550W Victron Energy 100 50 Victron Energy 100 20 FLINflex 600W Victron Energy 100 50 Victron Energy 100 30 Victron Energy 100 20 The MPPT solar charge controllers from Victron Energy and Genasun feature very fas...

Страница 11: ...trical connection faulty No too little light output on the system Module damaged Check plug Check cables Check modules for shadows FLINflex provides only small electrical power Little light output on the system Electrical connection is faulty Battery is defective Module damaged Clarify shading covering of the modules Check cables and plugs for defects Check battery ...

Страница 12: ...ke care especially during assembly and disassembly not to be injured by moving parts During assembly and disassembly be careful not to get caught or crushed in parts Do not disregard the safety rules even after repeated use Electrical safety The connection plug of the solar system must fit into the coupling socket The plug must not be modified Do not use approved adapter plugs Do not misuse the co...

Страница 13: ... consequences for the environment Competent authorities have further information available 12 Declaration of comformity FLIN solar GmbH hereby declares that the products bearing the name FLINflex are in compliance with the RoHS Directive 2011 65 EU Management Hochfeldt Näthke The product must not be disposed of with household waste The product is RoHS compliant It therefore complies with Directive...

Страница 14: ...en nun ohne Geräuschemissionen unabhängig vom Stromnetz an abgelegenen Orten vor Anker oder während Sie mit ihrem elektrischen Motor fahren die Energie der Sonne für sich effizient umsetzen und nutzen Bitte lesen Sie die Bedienungsanleitung und Sicherheitshinweise aufmerksam durch bevor Sie das Produkt in Gebrauch nehmen Befolgen Sie die aufgeführten Hinweise und Tipps damit Sie Ihr FLINflex optim...

Страница 15: ...en 15 4 Technische Daten des Systems 16 5 Lagerung des FLINflex 18 6 Varianten 18 6 1 Befestigungssysteme 18 6 2 Kabel 19 7 Aufbau 19 7 1 FLINflex standard 19 7 2 FLINflex snap 19 7 3 FLINflex eyelet 20 7 4 FLINflex tex 20 7 5 FLINflex magnetic 20 8 Anschluss an das Bordnetz 20 9 Fehlersuche 22 10 Sicherheitshinweise 22 11 Wichtige Hinweise zur Entsorgung 23 12 Konformitätserklärung 24 ...

Страница 16: ...umfang FLINflex Bedienungsanleitung 2 Zusätzlich benötigt MPPT Regler abgestimmt auf die Leistung des FLINflex und auf Ihr Bordnetz Anschluss vom Regler zum FLINflex Decksdurchführung oder MC4 Verlängerungskabel Anschluss vom Regler zur Batterie 3 Produktvarianten FLINflex 50W FLINflex 100W FLINflex Custom ...

Страница 17: ...p MC4 Gewicht 830g Leistung 50W Leistung bifazial 60W VOC 6 4V 12 8V 6 4V 12 8V ISC 9 7A 4 85A 9 7A 4 85A ISC Bifazial 10 67A 5 345A VMPP 5 6V 11 2V 5 6V 11 2V IMPP 8 9A 4 45A 8 9A 4 45A IMPP Bifazial 10 62A 5 31A Schutzart IP67 Es besteht zusätzlich die Möglichkeit ein angepasstes Solarpanel zu fertigen Die Parameter können je nach Konfiguration abweichen Hinweis Die aufgeführten Daten sind Richt...

Страница 18: ...50g Leistung 100W Leistung bifazial 120W VOC 12 9V 25 8V 12 9V 25 8V ISC 9 7A 4 85A 9 7A 4 85A ISC Bifazial 10 67A 5 345A VMPP 11 3V 22 6V 11 3V 22 6V IMPP 8 9A 4 45A 8 9A 4 45A IMPP Bifazial 10 62A 5 31A Schutzart IP67 Es besteht zusätzlich die Möglichkeit ein angepasstes Solarpanel zu fertigen Die Parameter können je nach Konfiguration abweichen Hinweis Die aufgeführten Daten sind Richtwerte die...

Страница 19: ...LINflex einwirken Es wird empfohlen den zusätzlich erhältlichen FLINbag in der entsprechenden Größe zu verwenden Abmessungen 680mm x 565mm x 100mm 1150mm x 550mm x 130mm 6 Varianten Die FLINflex Serie ist durch verschiedene Befestigungssysteme und Kabelvarianten in hohem Maße anpassbar Je nach Anwendung kann die passende Konfiguration gewählt werden 6 1 Befestigungssysteme Standard Keine Befestigu...

Страница 20: ...Es können auch FLIN Solarmodule unterschiedlicher Größe miteinander kombiniert werden Ein Anschlussbeispiel finden Sie im Downloadbereich unserer Website 7 1 FLINflex standard Der FLINflex standard hat keine weiteren Befestigungsmöglichkeiten Er kann z B über den ca 25 mm breiten Rand mit dem Deck verschraubt oder fliegend verwendet werden Wichtig ist dass bei der Verschraubung ein Mindestabstand ...

Страница 21: ...e Fläche nähen Dann kann das FLINflex tex sehr schnell montiert und demontiert werden 7 5 FLINflex magnetic Durch die Magnetfolie auf der Rückseite des Solarmoduls findet das FLINflex magnetic auf jeder stahl oder eisenbasierten Metalloberfläche Halt Je nach Sonnenstand kann es zum Beispiel an der Autotür oder beim Camping auf dem Dach befestigt werden Für eine unabhängige Stromversorgung können b...

Страница 22: ...on Energy 100 30 Victron Energy 75 15 FLINflex 450W Victron Energy 100 30 Victron Energy 75 15 FLINflex 500W Victron Energy 100 50 Victron Energy 100 20 FLINflex 550W Victron Energy 100 50 Victron Energy 100 20 FLINflex 600W Victron Energy 100 50 Victron Energy 100 30 Victron Energy 100 20 Die MPPT Solarladeregler von Victron Energy und Genasun verfügen über ein sehr schnelles Maximum Power Point ...

Страница 23: ... die für die Sicherheit verantwortliche Person übergeben wurde Es ist dafür zu sorgen dass Kinder nicht mit dem System spielen Vergewissern Sie sich vor Inbetriebnahme dass die vorhandenen technischen Daten auf den Regler und das Bordnetz abgestimmt sind Achten Sie darauf dass Sie die Ausgangsleitungen nur in eine geeignete Bordsteckdose stecken Ziehen Sie nie an den Leitungen sondern fassen Sie s...

Страница 24: ...rleistung beträgt 24 Monate ab Kaufdatum gegen Vorlage des Kassenbeleges bzw der Rechnung Bei nicht zweckbestimmter Anwendung des Gerätes bei Betrieb außerhalb der technischen Spezifikationen unsachgemäßer Bedienung oder Fremdeingriff erlischt die Gewährleistung Für daraus entstandene Schäden wird keine Haftung übernommen Der Haftungsausschluss erstreckt sich auch auf jegliche Service Leistungen d...

Страница 25: ...kt darf nicht über den Hausmüll entsorgt werden Das Produkt ist RoHS konform Es entspricht somit der Richtlinie 2011 65 EU zur Beschränkung gefährlicher Stoffe in Elektro und Elektronik Geräten Druckfehler Irrtum und technische Änderungen vorbehalten Alle Rechte insbesondere der Vervielfältigung sind vorbehalten Made in Germany by FLIN solar GmbH Anschrift Christianspries 30 D 24159 Kiel Telefon 4...

Страница 26: ...FLINflex FLIN solar GmbH Christianspries 30 24159 Kiel 49 0431 60109038 info flin solar de 25 DE ...

Страница 27: ...FLINflex FLIN solar GmbH Christianspries 30 24159 Kiel 49 0431 60109038 info flin solar de 26 DE ...

Страница 28: ...FLINflex FLIN solar GmbH Christianspries 30 24159 Kiel 49 0431 60109038 info flin solar de 27 DE ...

Отзывы: