long as either main battery has power re-
maining, however, after approximately 10
minutes the emergency lights automatically
time out but may be reset by cycling the EMER
LIGHTS switch to OFF and back ON.
If both of the airplane main batteries expire,
the emergency battery will continue to provide
power to the cockpit instruments illustrated in
Figure 3-12. The left cockpit overhead light,
the left map light and the floodlights will be
lost. The landing gear indicator lights and the
magnetic compass light will continue to op-
erate, however, all instrument panel and
pedestal switch/indicator lights will be inop-
erable.
L E A R J E T 4 5
P I L O T T R A I N I N G M A N U A L
3-11
FOR TRAINING PURPOSES ONLY
FlightSafety
international
AUDIO
CONTROL
PANEL
AUDIO
CONTROL
PANEL
RMU
#1
RMU
#2
4
5
6
CREW WARNING
PANEL
CDH
LANDING GEAR INDICATOR LIGHTS
STANDBY COMPASS
Figure 3-11. Battery Mode Lighting
RMU
#1
4
5
6
LANDING GEAR INDICATOR LIGHTS
STANDBY COMPASS
Figure 3-12. Emergency Battery Mode Lighting