background image

Flight 60

® 

iO

2

 

Quick Reference Guide

This quick reference guide does not replace the Flight

60 Operator’s Manual. The Flight 60 Operator’s Manual

containing instructions, warnings, cautions and other

important information for the safe and proper use of this

product must be carefully read prior to

using the Flight60 ventilator.

Not yet cleared for use in the USA

Alarms & Power Management

Patient Monitoring

Controlled Parameters

 Alarm Reset

Circuit Connectors

Nebulizer Port 

*

ON/OFF

Содержание Flight 60 iO2

Страница 1: ...Manual containing instructions warnings cautions and other important information for the safe and proper use of this product must be carefully read prior to using the Flight60 ventilator Not yet cleared for use in the USA Alarms Power Management Patient Monitoring Controlled Parameters Alarm Reset Circuit Connectors Nebulizer Port ON OFF ...

Страница 2: ...ent Circuit or components of a patient Circuit are replaced 2 1 Connect an adult 500 ml test lung with a 90 degree elbow to the Flow Sensor s patient side 2 Press the Technical button once and then tap the Circuit TEST button 3 Press Enter Circuit TEST ...

Страница 3: ...tion Turn on the ventilator by pressing the On Off button Start ventilation by pressing and holding the On Off button for 2 seconds Stopping Ventilation Shutting Down Press the On Off button once than again for 2 seconds ...

Страница 4: ...ALARMS 21 100 O2 OFF Nebulizer OFF SIMV PCV Trigger sensitivity setting Pressure Support setting 2 Minutes 100 O2 To Alarms Screen Volume Pressure Setting Nebulizer ON OFF Volume or Pressure Ventilation Selection Ventilation Modes ACMV SIMV SPONT CPAP VtG MVG B LEV Not yet cleared for use in the USA ...

Страница 5: ...Delay OFF Hold Length 3 Maneuvers OFF Altitude Compensation Non Invasive ON OFF MVG Trigger Delay ON OFF Inspiratory Expiratory Hold Controls the length of the maneuver Square or Descent VtG Tidal Volume Guarantee MVG Minute Volume Guarantee Flow Termination Cycling from 10 to 70 of the peak flow Limit the inspiratory time in Pressure Support ...

Страница 6: ...i 1 0 Waveform Square ALARMS Screen High Rate Buzzer LOW OFF LOW Rate OFF LOW Vte OFF LOW Vti OFF Apnea Interval 20 HIGH P LOW P 3 99 LOW MV 0 1 HIGH MV 20 0 FiO2 Low OFF FiO2 High OFF 6 Alarms Screen Buzzer Level Selection Apnea Interval Setting FiO2 Alarms ON OFF ...

Страница 7: ...et Load Save Set Clock Show Log Alarm Show Log Change Goto More on screen button The control button turns orange and a pop up list with the numbers of the saved configurations appears Select the number of the saved configuration Ventilation parameters will be adjusted to the saved configuration under the selected preset number Preset Load ...

Страница 8: ...Flight Medical Innovations Ltd www flight medical com Local support 1866 6587793 LIT 0017 REV A01 For Local Sales Contact ...