9/14/07 1/4 400-610-000-E
The FLP12 programmable thermostat, specially designed for floor
heating installations, is equipped with two ultra-precise sensors
which allow temperature control by separately monitoring both floor
and ambient settings, thus providing greater comfort.
The control module has four DIP switches to select the following
options:
Time and Temperature
Display (1)
•
°F/12h
•
°C/24h (default)
Early Start (2)
•
E.S. On
•
E.S. Off (default)
This function determines the optimal system start time to obtain the
desired temperature by the set time. When this function is enabled, the
system can be activated a few hours before the program’s start time.
Temperature Control (3)
This model offers the following three types of temperature control:
Permanent Backlight (4)
•
P.B. On (The display remains lit all the time.)
•
P.B. Off (default. The display is lit for 12 seconds when the
adjustment ring or any button is pressed.)
Align the bracket tabs on the
control module with the holes
located on top of the previ-
ously installed power base
and secure the module to the
base.
NOTE:
Keep the thermostat's air vents clean and free from
obstructions.
First Power On
When power is applied for the first time, the
screen displays 0:00 MO (Monday) as well as
the ambient/floor temperature.
If a problem occurs, one of the following mes-
sages will be displayed:
LO
:
the temperature is below 0°C (32°F) The
heating indicator is displayed and the system is activated.
HI
:
the temperature is above 70°C (158°F).
Er
:
the floor sensor is not connected properly or defective (temp.
control F) or the ambient sensor is defective (temp.
control AF).
To verify if the thermostat detects the floor sensor, select the
temperature control F (see DIP Switch Configuration). If the screen
displays
Er
, the floor sensor is not connected properly or defective.
If the screen displays the temperature, the sensor works.
DIP SWITCH CONFIGURATION
Temp.
control
Switch
position
Notes
Ambient with
floor limits
DOWN (AF)
Requires a floor sensor
Floor
(default)
UP (F)
Requires a floor sensor
Ambient
DOWN (AF)
Use only when floor sensor is
not
installed.
Not
recommended for floor heating
INSTALLATION
FLP12 - Control Module
User Guide
Current program number when
Automatic mode is activated
Room or floor
temperature.
Arrow indicates
a setpoint
Indicates the amount
of power sent to the
floor heating system
Vacation
mode
Current time
and day
Economy setpoint
Manual
mode
Temperature
adjustment
ring
Day
setting
To program
and view the
schedule
Comfort,
Economy and
Vacation
setpoints
ON/OFF—To turn On/Off the
thermostat and GFCI reset
Time
setting
To clear a
program
To select a mode
or to exit
programming
mode
Comfort setpoint
Floor
minimum
and
maximum
temperature
(AF only)
GFCI test
button and
warning light
400-610-000-E (Flextherm FLP12 prog CAN) ENG.fm Page 1 Friday, September 14, 2007 4:13 PM