7 Connection
FLUXUS WD
7.2 Power supply
61
UMFLUXUS_WDV1-3EN, 2018-07-16
7
Connection
7.2
Power supply
The installation of the power supply is carried out by the operator. The operator has to provide an overcurrent protector
(fuse or similar device) disconnecting all energizing wires in case of an inadmissible high current consumption. The imped-
ance of the protective earth has to be low ohmic in order not to allow touch voltage pass the permissible limit. The equipo-
tential bonding terminal serves as functional earth of the transmitter, see Fig. 7.8.
• Connect the power cable to the transmitter.
For the connection of the power supply cable to the transmitter, see section 7.2.1, Fig. 7.9 and Tab. 7.6.
Important!
The degree of protection of the transmitter will only be guaranteed if the power cable fits firmly and tightly in the cable
gland.
Fig. 7.8:
Equipotential bonding terminal on the transmitter
1 – equipotential bonding terminal on stainless steel housing
2 – equipotential bonding terminal on aluminum housing
Fig. 7.9:
Connection of the power supply to the transmitter
1 – fuse
2 – connection of the power supply
1
2
A
B
SNAP
DISP
DISP
MODE
FAST
MUX
NEXT
Q
ON
Q+
Q-
3x Q
OFF
LAN
USB
A+
B-
P1+
P2+
P3+
P4+
P5a
P6a
P7a
S
S
P1-
P2-
P3-
P4-
P5b
P6b
P7b
X2
X3
X_AV
KL1
1
KL12
KL7
KL8
KL9
KL10
KL4
X_AR
X_BV
X_BR
T1A
T1B
S1
T2A
T2B
T3A
T3B
S3
T4B
T4A
T1a
T1b
S1
T2a
T2b
T3a
T3b
S3
T4b
T4a
N(-)
PE
L(+)
AV
AV
S
AGN
ARS
AR
BV
BVS BGN
BRS
BR
KL4
N(-)
PE
L(+)
1
2
Содержание FLUXUS WD
Страница 1: ...FLUXUS WD UMFLUXUS_WDV1 3EN Operating instruction...
Страница 6: ...Table of contents FLUXUS WD 2018 07 16 UMFLUXUS_WDV1 3EN 6...
Страница 150: ...18 Settings 18 9 Key lock FLUXUS WD 2018 07 16 UMFLUXUS_WDV1 3EN 150...
Страница 171: ...Annex FLUXUS WD D Conformity declarations 171 UMFLUXUS_WDV1 3EN 2018 07 16 D Conformity declarations...
Страница 172: ...Annex D Conformity declarations FLUXUS WD 2018 07 16 UMFLUXUS_WDV1 3EN 172...
Страница 173: ......
Страница 174: ......