16 Advanced functions
FLUXUS F808
16.3 HybridTrek mode
129
UMFLUXUS_F808V2-2EN, 2020-06-25
16.3
HybridTrek mode
The HybridTrek mode combines the TransitTime and the NoiseTrek mode. During a measurement in the HybridTrek
mode, the transmitter automatically toggles between the TransitTime and the NoiseTrek mode depending on the gaseous
or solid content in the fluid in order to receive valid measuring values.
• Select
Special Funct.\SYSTEM settings\Measuring
.
• Press ENTER until the menu item
Enable NoiseTrek
is displayed.
• Select
on
to enable the NoiseTrek mode,
off
to disable it.
• Press ENTER.
• Select
no
to deactivate the automatic toggling between the TransitTime and the NoiseTrek mode. If
no
is selected, the
NoiseTrek mode can only be activated and deactivated manually during the measurement.
• Select
yes
to activate the automatic toggling between the TransitTime and the NoiseTrek mode. If
yes
is selected, the
NoiseTrek mode can also be activated and deactivated manually during the measurement.
• Press ENTER.
This display will only be indicated if the NoiseTrek mode is enabled and the NoiseTrek parallel beam mode has not been
activated yet.
If the automatic toggling between the TransitTime and NoiseTrek mode is activated, the toggling parameters have to be
configured.
• Enter the time after which the transmitter has to toggle to the NoiseTrek mode if there are no valid measured values in
the TransitTime mode. If zero is entered, the transmitter does not toggle to the NoiseTrek mode.
• Press ENTER.
• Enter the time after which the transmitter has to toggle from the NoiseTrek to the TransitTime mode if there are no valid
measured values. If zero is entered, the transmitter does not toggle to the TransitTime mode.
If there are valid measured values in the NoiseTrek mode, the transmitter can periodically toggle to the TransitTime mode
in order to check whether a measurement in the TransitTime mode is possible again. The time interval and the duration of
the checking are set as follows:
• Enter the time after which the transmitter has to toggle to the TransitTime mode. If zero is entered, the transmitter does
not toggle to the TransitTime mode.
• Press ENTER.
• Enter the time after which the transmitter has to toggle from the TransitTime mode back to the NoiseTrek mode if there
are no valid measured values.
• Press ENTER.
Notice!
Due to its higher measuring accuracy, the TransitTime mode should be used preferentially over the NoiseTrek mode.
Special Funct.\SYSTEM settings\Measuring\Enable NoiseTrek
Special Funct.\SYSTEM settings\Measuring\Enable NoiseTrek\Auto NoiseTrek
Special Funct.\...\Auto NoiseTrek\TT-Failed |After
NoiseTrek
Special Funct.\...\Auto NoiseTrek\NT-Failed |After
TransTime
Special Funct.\...\Auto NoiseTrek\NT-Ok,but |Each check TT
Special Funct.\...\Auto NoiseTrek\Keep TT |For checking