7. Survey of possible malfunctions and irregularities in operation
7.1. General list
MALFUNCTION
CAUSE
ELIMINATION
-
there is no voltage
on the control panel
at switching on
-
there
is no power supply from the
power net on one or more phases
-
fuse 100mA on the control panel is
burned through
-
there is no control
power
-
replace fuse 100mA and
check the cause of burning
-
contact authorized service
personnel to resolve the
problem
-
By switching
on,
the switches on the
control panel display
the voltage, but the
boiler does not heat
-
check the adjustment of the room
t
hermostat,
-
limiting thermostat is activated
-
indicator of air presence in the boiler
blocked the operation,
-
defective switch,
-
heaters are burned through
-
check the set temperature on
the room thermostat, replace
batteries, or the room
thermostat is faulty,
-
vent the boiler in order to turn
off the lamp “air in boiler”
-
temperature in
boiler is on desired
value, but radiators
do not heat
-
circulation pump does not operate,
-
air stopper on central heating
installation prevents
circulation
-
vent installation
-
boiler does not
provide enough
heat
-
one phase is missing on supply
-
a part of heater is burned through
-
in a three
-
phase system the three
different phases are not brought to the
boiler
-
check fuses on the main
panel,
-
contact authorized service
personnel to resolve the
problem
-
the switcher can
be heard while
operating (it
buzzes)
radio and TV
-
interferences
-
poor voltage in the net
-
defective relay
-
contact authorized service
personnel to resolve the
problem
-
boiler in
operation “roars”
-
the system is
not well vented
,
-
defective
heater
-
vent
the system
-
contact authorized service
personnel to resolve
problem
-
pressure in the
system varies
-
defective expansion vessel,
-
the vessel pressure is too low or too
high
-
contact authorized service
personnel to resolve the
problem
-
the actual
temperature in the
boiler is higher than
the desired
temperature and the
safety thermostat is
activated
-
defective relays
-
contact authorized service
personnel to resolve the
exact source of the
problem
-
RCCB switch
disconnects
(in
home fuse box)
-
defective heater,
-
humidity on conductors,
-
safety thermostat is activated
-
check leakage,
-
contact authorized service
personnel to resolve the
exact source of the
problem