Connection of concentric roof flue kit C32
The combustion air is taken directly into the room and the smoke exhaust is done to the exterior thanks to a
concentric flue kit through the roof.
The use of roof chimney implies the to take the air combustion from the room where the heater is installed.
Caution
: The flue pipe must be solidly fixed to be stable. The flue pipe cannot solely be held by the unit in
any case.
It is possible to extend or divert the concentric kit with approved accessories.
The use of flues involves a parfait sealing. To facilitate the installation, it is necessary to use a lubricant, non
-
aggressive for the gasket, example: soapy water.
CAUTION
Accumulated losses cannot exceed available losses.
The given losses are made with the accessories we sale or recommend with our range of heaters.
With concentric pipes, accumulate the losses of air combustion intake and smoke exhaust.
1
5
2
3
4
1
3
4
2
Axial gas heater :
Vertical gas heater :
Composition of the kit C32 :
(1) 1 tee with purge and removable cap
(2) 1 single elbow at 90°
(3) 1 single extension to adjust
(4) 1 concentric roof terminal with flashing
Additional accessories :
Concentric elbow
Single elbow
Single extension of 1 meter
Concentric extension of 1 meter
Composition of the kit C32 :
(1) 2 single extensions
(2) 1 tee with purge
(3) 1 single elbow at 90°
(4) 2 single elbows at 45°
(5) 1 concentric roof terminal with flashing
Additional accessories :
Concentric elbow
Single elbow
Single extension of 1 meter
Concentric extension of 1 meter
* Only available for ATXH
Model of the heater
FHATX25
* FH
ATX35 FHATX45 FHATX60 FHATX80
Diameter of flue pipes 80 mm 80 mm
80 mm
80 mm
100 mm
Fumes mass flow 8 % O2
49 Kg/h
68 Kg/h
86 Kg/h 113 Kg/h 148 Kg/h
Available losses of air / fumes
120 Pa
200 Pa
250 Pa
300 Pa
240 Pa
Losses of Kit C32
30 Pa
50 Pa
80 Pa
135 Pa
60 Pa
Losses for additional single extension of 1m
2 Pa
4 Pa
7 Pa
12 Pa
5 Pa
Losses for additional concentric extension of 1m
4 Pa
6 Pa
9 Pa
15 Pa
10 Pa
Losses for additional 90° single elbow
8 Pa
15 Pa
25 Pa
40 Pa
15 Pa
Losses for additional 90° concentric elbow
10 Pa
18 Pa
33 Pa
50 Pa
25 Pa