Pre Use Inspection
16
Flexi ACiON Operator Handbook
Other Options
Keypad Entry (Electronic Code
Switch ECS)
Indication Lamps (LED’s)
In normal operating mode, the red LED will flash
each time a correct keystroke occurs. To indicate the
switch is ON, the green LED is activated.
When the ECS is in the programming mode, the red
LED is on. Now the green LED will indicate a correct
keystroke.
User Pin Codes
Up to 15 individual PIN codes can be programmed.
Each PIN code consists of at least 4 and a maximum
of 8 digits.
To be sure no accidental keystrokes remain, press
the CE key before entering your PIN code. Terminate
your PIN code with the ON/OFF key to switch ON.
Once the switch is activated it can be turned OFF by
pressing the ON/OFF key again. The switch will be
turned OFF immediately.
If an incorrect PIN code is entered just press the CE
key and restart entering the correct PIN code
followed by the ON/OFF key.
Master Pin Code
With the master code you can program all PIN codes
and also the switch OFF delay. Keep your personal
master code in a safe place.
WARNING: If the master code is forgotten or
lost, the ECS can not be reprogrammed and
must be returned for resetting. The cost for
resetting will be charged.
For supervisors instructions, contact
Narrow Aisle
Limited.
Switch Off Delay
It is possible to configure the switch to turn OFF after
being switched ON for the programmed number of
minutes. If connected through the seat switch, the
ECS will shut down after the programmed delay
which starts when the driver leaves the seat.
For supervisor’s instructions, contact
Narrow Aisle
Limited.
Pyroban System 4000
A truck may be fitted with Pyroban System 4000 if it
is operated in hazardous areas. To operate a vehicle
fitted with this system it is necessary to follow the
following start-up sequence.
•
Insert key and turn fully clockwise, release and
allow to return to the ON position. This will
activate the System 4000.
•
The System 4000 display will show the progress
of the start-up sequence.
•
When requested to do so by the System 4000,
operate the gas bottle test valve to enable a
sufficient amount of gas into the gas sensing
head.
•
The System 4000 will indicate when the gas test
is complete and the gas is being purged from the
system.
•
When the sequence is completed satisfactorily
the System 4000 will display
SYSTEM OK
. The
truck can now be operated.
•
Any other fault code MUST be reported to your
Pyroban Trained Engineer.
Note:
Trucks fitted with a Pyroban system MUST
only be maintained or repaired by Pyroban Trained
Personnel.
For further information on any of the above options
please contact the manufacturer.
Содержание Flexi ACiON 1000
Страница 1: ...Issue A 25 6 2019 Flexi ACiON Operator Handbook VNA 1000 1100 1200 1250 1350 1400...
Страница 5: ...Technical Specification 1A Flexi AC Operator Handbook...
Страница 7: ...Technical Specification 3 Flexi ACiON Operator Handbook Dimensions...
Страница 16: ...Technical Description 12 Flexi ACiON Operator Handbook Controls Etc...