Technical Description and Installation Manual 

GigaFlex 

 

VERSION CONTROL 

Manual 

Version 

Date 

Major changes to previous version 

1.0 

07.02.2019  Initial Version 

1.1 

11.10.2019 

Chapter 1 

“Selection Guide” corrected 

Chapter 2 

“Precaution” corrected 

Figure 3-2 corrected 
Table 3-1 corrected 
Chapter 3.3.1.4 

“Master and Slave Mode” corrected 

Chapter 3.3.2.1 

“Power Over Ethernet (PoE)” corrected 

Chapter 6.1.5 

“Digital Input / Output Interface (2I2O)” corrected 

Chapter 6.3 

“Power Supply” corrected 

Chapter 6.4.2 

“Safety / EMC” corrected 

SAFETY REGULATIONS 

IF THE UNIT IS NOT USED IN ACCORDANCE TO REGULATIONS DESCRIBED AND DEFINED IN THE 
CHAPTERS 

“TECHNICAL  DESCRIPTION”  AND  “TECHNICAL  SPECIFICATIONS”,  FLEXDSL 

TELECOMMUNICATIONS  AG  REFUSES  TO  TAKE  ANY  RESPONSIBILITY.  FURTHERMORE,  NO 
WARRANTY IS GRANTED IN SUCH CASE! 

IT’S ONLY ALLOWED TO USE EXTERNAL POWER SUPPLYS THAT ARE APPROVED ACCORDING 
TO THE SAFETY STANDARD IEC/EN 60950-1. 

THE  DISCONNECTING  DEVICE  FOR  THE  RACK  IS  THE  MAINS  PLUG  AND/OR  THE  APPLIANCE 
COUPLER.  THE  MAINS  PLUG  AND/OR  THE  APPLIANCE  COUPLER  HAS/HAVE  TO  BE  EASILY 
ACCESSIBLE AND THE MAINS PLUG HAS TO BE NEXT TO THE RACK IF THE MAINS PLUG SERVES 
AS THE DISCONNECTING DEVICE. 

IT’S  ONLY  ALLOWED  TO  USE  THE  UNITS  WITH  HOUSINGS  SUPPLYED  FROM  FLEXDSL 
TELECOMMUNICATIONS AG (SUBRACKS, MINIRACK, UTTX). THE RACK HAS TO BE CONNECTED 
PERMANENTLY  TO  A  RELIABLE  PROTECTIVE  EARTH  CONDUCTOR.  THE  LTU  UNIT  AND 
LINECARDS HAVE TO BE FIXED TO THE RACK PERMANENTLY WITH THE TWO PANEL SCREWS. 

INCORRECT USE OF THIS DEVICE, USE IN ANY OTHER ENVIRONMENT AND/OR HOUSING THAN 
PROVIDED  BY  FLEXDSL MIGHT  LEAD TO  HARMFUL  CONDITIONS. FAILURE TO FOLLOW THESE 
PRECAUTIONS MAY RESULT IN DEATH, SEVERE INJURY OR PROPERTY DAMAGE. 

Please read this manual carefully before operating the system. 
Installation of this equipment must be done by 

qualified

 personnel only. 

EU DIRECTIVE 2002/96/EC AND EN50419 

 

Our equipment is marked with the recycling symbol. It means that at the end of 
the  life  of  the  equipment  you  must  dispose  it  separately  at  an  appropriate 
collection point and not place it in the normal domestic unsorted waste stream. 
(European Union only)

 

 

Содержание GF-RAIL2N-6Eth-24V,V26

Страница 1: ...FlexDSL GigaFlex DIN RAIL UNITS TECHNICAL DESCRIPTION AND INSTALLATION MANUAL Version 1 1 Document name UM_Flexdsl Gigaflex_Installation_V1 1 Docx Revision 11 October 2019...

Страница 2: ...ed in any part or as a whole transcribed stored in a retrieval system translated into any language or transmitted in any form or by any means electronic mechanical magnetic optical chemical photocopyi...

Страница 3: ...erfaces 14 3 3 2 1 Power Over Ethernet PoE 15 3 3 3 Serial Interface 15 3 3 4 Inputs and Outputs 15 3 3 5 LCT USB Connector 16 3 3 6 SD Card and USB Host 16 3 3 7 Factory Default Button Default IP Add...

Страница 4: ...S PLUG AND OR THE APPLIANCE COUPLER THE MAINS PLUG AND OR THE APPLIANCE COUPLER HAS HAVE TO BE EASILY ACCESSIBLE AND THE MAINS PLUG HAS TO BE NEXT TO THE RACK IF THE MAINS PLUG SERVES AS THE DISCONNEC...

Страница 5: ...TP 2 step SyncE MACsec PoE GF RAIL2N 6Eth 2I2O 2SER 24V V21 1 1 GF RAIL2N 6Eth 2I2O 2SER PoE 24V V25 1 1 GF RAIL2N 6Eth 24V V26 1 1 GF RAIL4N 6Eth 2I2O 2SER 24V V31 1 1 GF RAIL4N 6Eth 2I2O 2SER PoE 24...

Страница 6: ...OPER USE OF OUR EQUIPMENT USE IN ANY OTHER ENVIRONMENT OR IMPROPER INSTALLATION AND MAINTENANCE MIGHT LEAD TO HARMFUL CONDITIONS FAILURE TO FOLLOW THESE PRECAUTIONS MAY RESULT IN DEATH SEVERE INJURY O...

Страница 7: ...tion greater reach and performance spectral compatibility lower power and application flexibility The FlexDSL GigaFlex product family offers the following features A dual wide range 24 48VDC power inp...

Страница 8: ...es is shown on Figure 3 2 Figure 3 2 Front panel for models without serial and IO interfaces The models with serial and IO interfaces have a front panel as shown on Figure 3 3 Figure 3 3 Front panel f...

Страница 9: ...he Unit DCE Corresponding DTE line RS232 RS485 full RS422 RS485 half Contact location 1 Out RXD Rx D 2 Out CTS Rx D 3 In TXD Tx nc 4 GND 5 GND 6 In RTS Tx nc 7 CC cable connect 8 GND IO LEDs Four bico...

Страница 10: ...f DSL 3 in shutdown state Red DSL 3 Major Alarm Red blinking DSL 3 training with remote end Amber DSL 3 Minor Alarm Green blinking DSL 3 Physical Layer up Data Layer down Green DSL 3 operates no Alarm...

Страница 11: ...ng TC PAM Trellis Codded Pulse Amplitude Modulation and sends a data flow to the receiving end over a twisted copper pair cable 3 3 1 1 Modulation and Data Rates The GigaFlex firmware supports TC PAM4...

Страница 12: ...an work into four independent directions 3 3 1 4 Master and Slave Mode An SHDSL link can be created if two transceivers on it ends operate in different modes It is required that one transceiver is con...

Страница 13: ...Daisy Chain Line Structure In a daisy chain you connect the devices in series and in each device you can add drop Ethernet data This can be realized with just one or multiple copper pairs Figure 3 6...

Страница 14: ...100 1000Base TX and four are connected to the SHDSL ports because the EFM chip operates as PHY These ports are not visible but must be configured according to desired application The Ethernet subsyst...

Страница 15: ...wer source for PoE functionality is possible by special internal jumper settings Please contact the manufacturer 3 3 3 Serial Interface The Serial interface of some GigaFlex models operates according...

Страница 16: ...can be found in the GigaFlex Configuration Manual 3 3 5 LCT USB Connector The Local Craft Terminal LCT Type Mini B USB connector allows local access to the command line interface of the GigaFlex model...

Страница 17: ...t improper ventilation voltage drops and peaks excessive moisture excessive electro magnetic impacts or insects or any creatures have been penetrated the device causing its malfunction as well as othe...

Страница 18: ...are not sure about a proper Protective Earth connection through the DIN rail mechanics please connect the Protective Earth to the corresponding connector on Figure 4 2 If you ave si gle power supply...

Страница 19: ...nclosure clean and periodically check the quality of contacts in jacks and in junctions We recommend that you perform the following measurements and keep the following records SHDSL Speed and Signal t...

Страница 20: ...6 1 3 10 100 1000Mbps Ethernet GE Standard IEEE 802 3 Data Rate 10 100Base TX Full Half Duplex 1000Base TX Full Duplex Protocols Layer 2 Layer 3 Signal Level Ethernet MDI MDI X auto crossover Support...

Страница 21: ...ot Specification Micro SD Type Host Class Class 2 6 2 Power over Ethernet PoE Specification PSE IEEE 802 3af 15 4W Output Power Power Input 18 72Vdc Electrical Isolation 1 5kVac 1 min PoE Voltage 56Vd...

Страница 22: ...1 2014 AC 2015 IEC 62368 1 2018 EMC emissions EN 300 386 V1 6 1 EN 55032 2015 CISPR 32 2015 EN 50121 4 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 EMC immunity EN 300 386 V1 6 1 EN 55035 2017 CISPR 35 20...

Отзывы: