Page 3 of 24
Features
*
5 YEAR WARRANTY.
*
COMPLETELY SEALED ELECTRONICS FOR MARINE OR OUTDOOR MOUNTING.
*
LOW BATTERY VOLTAGE INDICATOR. (FLASHING RED LIGHT).
*
Works with GEL, AGM, and Flooded Cell Lead Acid Batteries. Also for flooded Ni-Cad Batteries
*
ARC REDUCTION CIRCUITRY TO ELIMINATE OR REDUCE RELAY CONTACT WEAR.
*
CHARGING EFFICIENCY BETTER THAN 99.50% FROM 0.5A TO 30A OF CHARGING CURRENT.
*
OPERATES EFFICIENTLY (98%) WITH AS LITTLE AS 0.1A OF SOLAR PANEL CHARGING
CURRENT.
*
EFFICIENTLY CHARGES BATTERIES FROM 0 VOLTS WITH FULL POWER.
*
No RFI or EMI emissions to interfere with radio or data logging equipment
*
25 AMP CHARGE CAPACITY. SPECIAL ORDER 24V, 36V, AND 48V MODELS, OR EXPANDED
MODELS WITH CHARGING CURRENT CAPACITIES UP TO 2000A.
*
25 AMP CHARGE DIVERT CIRCUIT. STABLE DIVERT CIRCUITRY PREVENTS ERATIC RELAY
SWITCHING IF CHARGE SOURCE VOLTAGE DROPS.
*
DIVERTS ONLY WHEN VOLTAGE AND CURRENT ARE AT USABLE LEVELS.
PERFECT FOR MOTOR TYPE DIVERT LOADS (FANS, PUMPS, etc...)
*
PEAK CHARGE VOLTAGE ADJUSTMENT WITH A RANGE OF 13.8V TO 15.9V (Multiply by 2,3,or 4
to
determine voltages for 24V, 36V, or 48V versions).
*
CHARGES WITH THE SAME HIGH ACCURACY VOLTAGE SENSING THROUGH BATTERY
ISOLATORS.
*
CONSUMES LESS THAN 5mA (0.005A) WHILE CHARGING AND AT NIGHT, 2mA IF YOU DO NOT
USE THE CHARGE INDICATOR.
*
CHARGES BATTERIES AT FULL POWER, BELOW THE PLATE SATURATION POINT, THIS
CHARGES BATTERIES FASTER, AND REDUCES ELECTROLYTE DEPLETION BY UP TO 90% OVER
CONVENTIONAL CONSTANT VOLTAGE, PWM, & HIGH FREQUENCY CHARGE REGULATORS.
*
BATTERIES START CHARGING AT 0.005A OF CHARGE CURRENT.
*
CONTROLLER CAN WITHSTAND OPEN CIRCUIT INPUT SPIKES OF 1500VA, & 140V CONTINOUS
WITHOUT DAMAGE.
*
REVERSE POLARITY AND TRANSIENT VOLTAGE PROTECTION ON THE BATTERY SENSE WIRES.
*
NO POWER WASTING SAMPLE PERIODS.
*
REMOTE BATTERY VOLTAGE SENSING SO THE CONTROLLER CAN BE MOUNTED ANYWHERE
BETWEEN THE CHARGING SOURCE AND THE BATTERIES.
*
EASY TO INSTALL USING THE LABELED CORROSION RESISTANT NICKEL / BRASS / STAINLESS
STEEL CONNECTOR.
*
U/L 94V-O RATED ENCLOSURE AND UL LISTED OR RECOGNIZED COMPONENTS.
Use Flooded Cell Battery settings for all AGM type batteries.
Содержание NC25A-12
Страница 11: ...Page 11 of 24...
Страница 12: ...Page 12 of 24...
Страница 13: ...Page 13 of 24...
Страница 14: ...Page 14 of 24...
Страница 15: ...Page 15 of 24...
Страница 16: ...Page 16 of 24...
Страница 17: ...Page 17 of 24...
Страница 18: ...Page 18 of 24...
Страница 19: ...Page 19 of 24...
Страница 20: ...Page 20 of 24...