background image

 

MD23-190 

 

User Guide 

Mid-Continent Instruments and Avionics 

User Guide UG190, Revision 2 

 

 

January , 2021 

 

The main display is divided into three segmented areas 

– the upper, middle, and lower 

panes.  Operation of each function and examples images are shown below.  

Turning the Control Knob right or left rotates between functions or indexes digits and 
highlights that element 

GREEN

 when selected. Pressing the Control Knob selects or toggles 

a highlighted function or sets a selected digital value and sequences to the next. 

UPPER PANE 

The Upper Pane always shows the time, time zone (UTC or LOCAL) and date. It also shows 
the status of the GPS time synchronization signal. See TIME under the Functions section for 
more details.   

MIDDLE PANE 

The Middle Pane provides control and an expanded view of one of the functions selected 
from the Lower Pane. When the unit is initially powered on, the Middle Pane is blank.  

LOWER PANE 

The Lower Pane shows the current active value of all four timer functions and allows any of 
them to be selected for an expanded view and control in the Middle Pane. The Middle Pane 
can be manually turned off by re-selecting the currently active function in the Lower Pane. 

4.1.2  CLOCK FUNCTIONS 

TIME 

When highlighting and selecting the current time zone in the Upper Pane (either UTC or 
LOCAL), three options become available to scroll and select between UTC, LOCAL, or 
LOCAL SET.  

In LOCAL SET mode, the hour and minutes can be changed to the desired values.  

A satellite icon is shown in either gray (off) or white (on) depending on whether the unit is 
currently receiving and synchronized with the GPS time from the incoming ARINC 429 signal. 
When no incoming signal is received or the unit is off, the unit maintains accurate time based 
on its internal clock and will re-synchronize when the signal is available. 

 

 

 

 

 

Normal View 

Time Zone Options 

 

(UTC mode shown) 

(Local Set mode shown) 

Содержание MidContinent MD23-190

Страница 1: ...ent regulatory requirements are qualified to install this equipment It is a supplement to the MD23 Installation Manual and Operating Instructions p n 9019161 If further information is required please...

Страница 2: ...set of data is referred to as a Custom Instrument Definition or a CID file The CID file for this instrument is pre loaded and may be available for future updates via a standard USB flash drive through...

Страница 3: ...tement of work and are not provided within this User Guide Connector Pinout Pin Description Function 1 Ground Power return connect to a c ground 2 ARINC Out A ARINC label 150 3 ARINC Out B paired with...

Страница 4: ...t MANUAL to start and stop the Flight Timer manually o select EXTERNAL to start the timer on an open signal Timer stops when grounded Hobbs Timer Pre Set to coincide with the existing aircraft engine...

Страница 5: ...the unit is initially powered on the Middle Pane is blank LOWER PANE The Lower Pane shows the current active value of all four timer functions and allows any of them to be selected for an expanded vie...

Страница 6: ...OP and RESET the timer manually by scrolling to and selecting the desired action If RESET is selected without first selecting STOP the timer will reset to zero and continue counting When the Flight Ti...

Страница 7: ...mer running Count down Timer T When the Count down Timer is selected from the Lower Pane the Lower Pane and Middle Pane will show HH MM SS The user can SET START STOP and RESET the timer manually by s...

Страница 8: ...ARINC input T Count up Stopwatch function with manual start stop reset T Count down Count down timer from user set value with manual start stop reset counts up after reaching zero 4 1 3 USER OPTIONS...

Страница 9: ...set to a different time than the GPS time even when GPS time is available In this case the time basis will continue to be synchronized but the manual UTC time will be stored and remembered as an offs...

Страница 10: ...ser to choose whether the seconds HH MM SS are shown ON or not shown OFF on the main display for both the time UTC and LOCAL and the Flight Timer This feature is to reduce clutter or distraction per u...

Страница 11: ...Hobbs timer if enabled via external signal 5 1 CONFORMANCE For standard conformance items such as qualification levels and software updates please refer to the IM 5 1 1 INSTRUCTIONS FOR CONTINUED AIR...

Отзывы: