Servicing
8.3 Replacing wearing parts
M3602-01en
Edition 09/2022
45
8.3.1
Replacing buffers (5) up to coupling size 400
8.3 Replacing wearing parts
Procedure
1. Remove the hexagon nuts (7).
2. Remove the bolts (4) with the washers (6) and the buffers (5) through the buffer fitting
holes.
3. Pull the buffers (5) off the bolts (4).
4. Clean the bolts (4), the washers (6), the buffer fitting holes and the bolt fitting holes in
the coupling parts 1 (1) and/or 3 (3).
5. Mount new buffers (5) on the bolts (4).
Please observe the information in section Use and storage of the buffers (5) (Page 73)
when replacing the buffers (5).
6. Insert the bolts (4) with the washers (6) and the buffers (5) through the buffer fitting holes
into the bolt fitting holes. Observe any markings that might be provided.
7. Secure the bolts (4) with new hexagon nuts (7) of the same quality.
8. Tighten the hexagon nuts (7) to the specified tightening torque T
A
ing torques and widths A/F (Page 72)).
8.3.2
Replacing buffers (5) as of coupling size 450 to 630
8.3 Replacing wearing parts
NOTICE
Blockage of cross bore of bolts (4)
The liquid screw locking agent can seal the cross bore of the bolts (4). Pressing out the
bolts (4) with grease then becomes difficult or completely impossible.
•
Apply only a small quantity of the liquid screw locking agent to the screws (11).
When removing the bolts (4), please observe the information in section Pressing out bolts
(Page 47).
Procedure
1. Remove the hexagon head screws (11) and the washers (8).
2. Remove the bolts (4) with the buffers (5) through the buffer fitting holes.
3. Pull the buffers (5) off the bolts (4).
4. Clean the bolts (4), the washers (6), the buffer fitting holes and the bolt fitting holes in
the coupling parts 1 (1) and/or 3 (3).
5. Mount new buffers (5) on the bolts (4). Please observe the information in section Use
and storage of the buffers (5) (Page 73) when replacing the buffers (5).
6. Insert the bolts (4) with the washers (6) and the buffers (5) through the buffer fitting holes
into the bolt fitting holes. Observe any markings that might be provided.
7. Push the washers (8) onto the screws (11).
8. Apply a small quantity of liquid screw locking agent (e.g. Loctite 243 medium strength) to
the screws (11).
Содержание RUPER RBS
Страница 1: ...RWB RBS Assembly and operating instructions M3602 01en Edition 09 2022 RUPEX...
Страница 6: ...Table of contents 6 Edition 09 2022 M3602 01en...
Страница 8: ...List of tables 8 Edition 09 2022 M3602 01en...
Страница 10: ...List of figures 10 Edition 09 2022 M3602 01en...
Страница 14: ...Introduction 1 4 Copyright 14 Edition 09 2022 M3602 01en...
Страница 36: ...Commissioning 36 Edition 09 2022 M3602 01en...
Страница 42: ...Operation 7 2 Faults causes and rectification 42 Edition 09 2022 M3602 01en...
Страница 52: ...Servicing 8 4 Removing coupling part 1 1 or 3 3 52 Edition 09 2022 M3602 01en...
Страница 54: ...Service and support 9 1 Contact 54 Edition 09 2022 M3602 01en...
Страница 56: ...Disposal 56 Edition 09 2022 M3602 01en...
Страница 62: ...Spare parts 11 2 Spare parts drawing and spare parts list 62 Edition 09 2022 M3602 01en...
Страница 76: ...Declaration of Conformity EU Declaration of Conformity 76 Edition 09 2022 M3602 01en...
Страница 77: ......