Model 7000SXT

Service Manual 

IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

Содержание 7000SXT

Страница 1: ...Model 7000SXT Service Manual IMPORTANT Fill in Pertinent Information on Page 3 for Future Reference...

Страница 2: ...drop below 32 F 0 C or above 110 F 43 C Do not place the unit in direct sunlight Black units will absorb radiant heat increasing internal temperatures Do not strike the valve or any of the components...

Страница 3: ...750 gallon setting K Electronic __________ Pulse Count __________ Meter Size 4 System Type A System 4 1 Tank 1 Meter Immediate or Delayed Regeneration B System 4 Time Clock C System 4 Twin Tank D Syst...

Страница 4: ...uld be the same size as the drain line flow control Refer to the dimensional drawing for cutting height of the distributor tube If there is no dimensional drawing cut the 4 distributor tube flush with...

Страница 5: ...the extra cycle button while the unit is in a regeneration cycle will cause the valve to advance to the next position Position the valve to backwash Ensure the drain line flow remains steady for 10 m...

Страница 6: ...o the next cycle step immediately by pressing the Extra Cycle button The Parameter display shows the current Cycle Step BW BF RR etc during regeneration and the Data display counts down the time remai...

Страница 7: ...Press the Extra Cycle button The service icon will flash to indicate that a regeneration is queued 1 To cancel a queued regeneration press the Extra Cycle button 2 Regenerating Immediately Press and...

Страница 8: ...ays equal to the regeneration day override pass before water usage depletes the calculated system capacity Time Clock Delayed Control A Time Clock Delayed Control regenerates the system on a timed int...

Страница 9: ...oring water usage and the display and motor shut down but it continues to keep track of the time and day for a minimum of 48 hours The system configuration settings are stored in a non volatile memory...

Страница 10: ...w Delayed FI Meter Flow Immediate tc Time Clock dAY Day of Week NT Number of Tanks 1 Single Tank System 2 Two Tank System Not Used TS Tank in Service U1 Tank 1 in Service U2 Tank 2 in Service Not Show...

Страница 11: ...bine Meter P0 7 3 4 Paddle Wheel Meter t1 0 1 Turbine Meter P1 0 1 Paddle Wheel Meter t1 5 1 5 Turbine Meter 7000 Default P1 5 1 5 Paddle Wheel Meter Gen Generic or Other Meter K Meter Pulse Setting M...

Страница 12: ...ettings and cycle to the next parameter Press the Extra Cycle button at the last parameter to save all settings and return to normal operation The control will automatically disregard any programming...

Страница 13: ...7000 Default Fltr Filter 7000 Default UFbF Upflow Brine First Not Used 8500 TwinFlo 100 Not Used Othr Other Not Used dFFF Down Flow Fill First IF Air Injected Oxidizer AIO 3 Control Type Display Code...

Страница 14: ...ia bed in grains of hardness when configuring a softener system and in the desired volume capacity when configuring a filter system This option setting is identified by C in the upper left hand corner...

Страница 15: ...eserve Since this value is expressed as a percentage any change to the unit capacity or feedwater hardness that changes the calculated system capacity will result in a corresponding change to the rese...

Страница 16: ...verride triggered regeneration This option setting is identified by RT in the upper left hand corner of the screen Use the Up and Down buttons to adjust the value as needed 13 Regeneration Cycle Step...

Страница 17: ...are set to OFF the unit will return to Day One until one or more days are set to ON 15 Current Day Display Code CD Press the Extra Cycle button Use this display to set the current day on systems that...

Страница 18: ...to specify the meter pulse setting for a non standard flow meter This option setting is identified by K in the upper left hand corner of the screen Use the Up and Down buttons to enter the meter const...

Страница 19: ...n The timer will discard any changes and exit User Mode if any button is not pressed for sixty seconds User Programming Mode Steps Press the Up and Down buttons for five seconds while in service and t...

Страница 20: ...5 identified by RC in the upper left hand Corner of the screen Press the Extra Cycle button Use this display to set the Current Day of the Week This option setting is 6 identified by CD in the upper...

Страница 21: ...ode after 60 seconds if no buttons are pressed Press the Extra Cycle button to exit Diagnostic Mode at any time Diagnostic Programming Mode Steps Press the Up and Extra Cycle buttons for five seconds...

Страница 22: ...his option setting is identified by RC in 6 the upper left hand corner of the screen Press the Up button Use this display to view the Software Version This option setting is identified by SV in 7 the...

Страница 23: ...Page 23 Notes...

Страница 24: ...Page 24 Powerhead Assembly 12 16 6 13 1 2 5 4 7 9 10 11 3 8 15 14 17 11 18 11 BR61501 7000SXT...

Страница 25: ...61693 01 Cover Assy 7000 SXT gray 1 61693 02 Cover Assy 7000 SXT black 9 1 40980 Back Plate 10 3 40967 Screw Slotted Hx Wshr Hd 1 4 20 x 1 LG 11 5 13602 Screw Phil Rd Hd 6 32 x 5 16 12 1 12473 Screw H...

Страница 26: ...Kit 7000 D F 5 1 60016 01 Brine Valve Assembly 7000 560CD 6 1 40577 Turbine Meter Assembly 7000 7 61454 000 Injector Assembly 7000 000 Injector Brown 61454 00 Injector Assembly 7000 00 Injector Viole...

Страница 27: ...4 7 0 gpm 61456 00 DLFC 1 Blank 61456 8 0 DLFC 1 8 0 gpm 61456 9 0 DLFC 1 9 0 gpm 61456 10 DLFC 1 10 0 gpm 61456 12 DLFC 1 12 0 gpm 61456 15 DLFC 1 15 0 gpm 61456 20 DLFC 1 20 0 gpm 61456 25 DLFC 1 25...

Страница 28: ...40563 11 Connector Assembly 1 BSP 7000 Plastic 2 40565 01 Connector Assembly 1 1 4 NPT 7000 Plastic 2 40565 11 Connector Assembly 1 1 4 BSP 7000 Plastic 2 61562 Connector Assembly 1 1 2 NPT 7000 Brass...

Страница 29: ...Hex 10 24 Nylon Black 5 1 19652 01 Poppet Assy SBV w O ring 6 1 19649 Flow Dispenser 7 1 11183 O Ring 017 8 1 19647 Elbow Safety Brine Valve 9 2 19625 Nut Assy 3 8 Plastic 10 1 18312 Retainer Drain 11...

Страница 30: ...g B Excessive water in brine tank B See problem 7 4 Loss of water pressure A Iron buildup in line to water conditioner A Clean line to water conditioner B Iron buildup in water condi tioner B Clean co...

Страница 31: ...id not cycle F Check drive motor and switches 9 Control cycles continuously A Misadjusted broken or shorted switch A Determine if switch or timer is faulty and replace it or replace complete power hea...

Страница 32: ...the unit itself Step the unit through a manual regeneration and verify that it functions correctly If the error re occurs unplug the unit and contact technical support 2 Regen Failure The system has...

Страница 33: ...r clockwise to the position shown in illustration above 3 Slightly pull the two tabs outward and push the gearbox slightly upward to remove 4 When returning valve to service after powerhead disassembl...

Страница 34: ...d align the notches on the left side of the board with the flexible finger on the power head Apply pressure to the left while rotating the board back 2 When all the way down snap the circuit board int...

Страница 35: ...otor connector A1 on board 2 Connect the transformer cable B to the transformer connector B1 on board 3 Connect the meter cable C to the meter cable connector C1 on board 4 Connect the meter cable sen...

Страница 36: ...Page 36 Water Conditioner Flow Diagrams In Service Position Backwash Position 40988_REVA 41121_REVA 40988_REVA 41121_REVA...

Страница 37: ...Page 37 Water Conditioner Flow Diagrams Brine Position Slow Rinse Position 40988_REVA 41121_REVA 40988_REVA 41121_REVA...

Страница 38: ...Page 38 Water Conditioner Flow Diagrams Rapid Rinse Position Brine Tank Refill Position 40988_REVA 41121_REVA 40988_REVA 41121_REVA...

Страница 39: ...Page 39 Injector Flow Data TR18755_REVB...

Страница 40: ...Page 40 Meter Flow Data TR18753 Softener TR18688 Filter 41140 02_REVA...

Страница 41: ...Page 41 Dimensions 41023_REVC...

Страница 42: ...Page 42 Notes...