› G e n e R a l   R e F e R e n C e

Please take a moment to review this page in order 
to familiarize yourself with these four ports on 
the valve and the programming values below. It is 
crucial not to mistake the inlet port with the outlet 
port. Mistaking and reversing the inlet and outlet 
ports will lead to failure of your softener system.

As you work through this guide, please make 
sure to follow all instructions exactly and to make 
special note of the bolded instructions and warn-
ing symbols. 

PdF viewers may click underlined 

text to jump to that page or the page number 
in the bottom corner of every page to jump to 
the table of contents.

 All our installation guides 

may be found on our site under “Information.”

d R a I n

B R I n e

› q u I C k   s ta R t

To the right are the program settings for your softener.  

If not all of the values are filled in, you can calcu-
late the missing values on pages 4 and 5
 of this 
guide.

 There we will cover identifying the 3 essential 

values of 

H - HardneSS

c - UnIT caPacITY

and 

BF - BrIne FIll

. The remaining values that are  

already filled in are general standards for all softener 
sizes and hardness levels.

MaSTer ProGraMMInG Mode:

 To enter in/check 

the adjacent values of your system, follow these steps: 
With either the up or down arrow button, change the 
clock to 12:01 PM, set the time by clicking the left-
most CYCLE / REGEN button, and then hold both the 
up and down arrow buttons for 5 seconds to enter 
master programming mode. Change values with the 
arrow buttons and set each value and advance to the 
next setting by clicking the CYCLE / REGEN button.

A more in-depth guide to programming the Fleck 
5600 SXT is provided beginning on 

page 11

.

o u t l e t

I n l e t

s e t t I n G

I n P u t   Va l u e

DF - Display Format

GAL - Gallons

VT - Valve Type

dF1b

CT - Control Type

Fd - Flow Delayed

NT - Number of Tanks

1

c - UnIT caPacITY

        ,000 Grains

H - HardneSS

       Grains per Gallon

RS - Reserve Selection

SF

SF - Safety Factor

15%

DO - Day Override

14 Days

RT - Regen Time

2:00 AM

BW - Backwash

10 Minutes

BD - Brine Draw

60 Minutes

RR - Rapid Rinse

12 Minutes

BF - BrIne FIll

       Minutes

FM - Flow Meter Type

t0.7 or P0.7

FM - Flow Meter Type

                    t0.7

                   P0.7

Job Number:   

 

Model Number:   

 

Mineral Tank Size:   

Содержание 5600SXT

Страница 1: ...Fleck 5600 SXT Metered Water Softener Install ation Guide v1 0...

Страница 2: ...values of H hARDNESS C UNIT cAPACITY and Bf bRINE FILL The remaining values that are already filled in are general standards for all softener sizes and hardness levels MASTER PROGRAMMING MODE To enter...

Страница 3: ...e of a new water softener with Fleck 5600 SXT Meter Control Valve from QualityWaterForLess com We have put together these instructions as reference and to be used as general installation guidelines It...

Страница 4: ...L are the same measure and both figures can be used interchangeably If you get a hardness level in PPM or mg L please divide this number by 17 1 to get Grains gpg Ex If your hardness is measured at 3...

Страница 5: ...K 12 Min 18 lbs TOO SMALL Grid 3 Legs Grid 3 Legs Grid 3 Legs Grid 6 Legs Grid 6 Legs 12 25 gpg 81K 20 Min 30 lbs TOO SMALL TOO SMALL Grid 6 Legs Grid 6 Legs 25 gpg 96K 30 Min 45 lbs TOO SMALL TOO SMA...

Страница 6: ...ig u r e 6 a Fig u r e 6 B pre install ation Before assembly of your new system be sure that the following conditions have been met for the place ment of your system Level firm surface such as concret...

Страница 7: ...stalling the fleck 5600 sx t Valve 1 Using caution not to lift the riser tube remove the filling funnel and tape While using the included silicone lubricant packet lu bricate the inner and outer o rin...

Страница 8: ...lines and use a wet rag on the lines being soldered to prevent heat damage during soldering 6 Once all connections have been made place the system into bypass by either using your existing 3 valve byp...

Страница 9: ...lso take this moment to prepare and insert the brine support grid determined from pages 4 and 5 Then pull the 474 Brine Float Assembly out of the brine well as shown in Figure 9 C 4 Next fix the 474 B...

Страница 10: ...be evenly press on both sides of the grey ring surrounding the tube and pull out as shown in Figure 10 A i Be sure to recut the end of the tube each time you remove it to ensure a proper seal when the...

Страница 11: ...ime to scroll faster Once the time display is set to 12 01 PM press the REGEN button once as shown in Figure 11 B 3 To enter MASTER PROGRAMMING MODE press the UP and DOWN buttons TOGETHER and HOLD bot...

Страница 12: ...your water listed on page 2 calculated on page 4 and press the REGEN button as shown in Figure 12 C 10 The display should now show RS SF as shown in Figure 12 D This indicates that the Reserve Selecti...

Страница 13: ...Figure 13 A This indicates the system will regenerate at 2 00 AM following the day the water consumption has passed the calculated capacity If you prefer an alternate regeneration time please enter i...

Страница 14: ...reen stops flashing BW let BW Backwash run for about 1 minute to observe the water leave out the drain line and check for leaks If you notice any leaks return to page 10 to review preparing the drain...

Отзывы: