background image

 

31

Premium Beverage Syrup Pump and Related Parts (See Figure 5C)

 

 

ITEM PART 

NO. 

DESCRIPTION 

QTY. 

FUNCTION 

N/A 

PREMIUM BEVERAGE SYRUP PUMP 
SYSTEM 

8* 

0** 

FOR “CBB” SYSTEMS

: Pumps syrup 

from bags into flavor lines. 
*8 for 80CBB systems. 
**0 for 80BEV, 80SS, 80BLD, 80FCB 
systems. 

N/A 

PREMIUM BEVERAGE SYRUP PUMP  1 ea.  Pumps syrup from bags to flavor lines. 

1A SYR 

926P 

PERISTALTIC SYRUP PUMP – 
PREMIUM BEVERAGE 

1 ea.  Pumps syrup from bags to flavor lines. 

1B  TUB 806 

1/8” SYRUP PUMP REPL TUBE  

1 ea.  Transports syrup through pump. 

1C  FAS 2067 

SYRUP PUMP TUBE WASHER-1/4 

1 ea.  Secures pump tube. 

1D  FAS 2066 

SYRUP PUMP CLAMP-HOSE-1/4" 

1 ea.  Prevents pump tube from slipping. 

1E  FAS 2051 

ROLLED FLANGE EYELET 

1 ea.  Creates tension for tighter fit. 

1F  FIX 1036 

1/4" TO 1/4" OD UNION ELBOW 

1 ea.  Connects syrup in tube to pump. 

1G  FIX 1035 

1/4 TO 3/16 OD REDUCING UNION 

1 ea.  Connects syrup pump to flavor line out. 

2 SYR 

945 

SYRUP TUBE ASSEMBLY – SOFT 
SERVE 

1 ea.  Transports flavor from bag to pump. 

2A  FIX 1054 

1/4” ID HOSE BARB SHUTOFF 

1 ea.  Connects flavor line to flavor bag. 

2B  SYR 902 

FLAVOR-IN TUBE 

1 ea.  Carries syrup from syrup bag to pump. 

2C  TUB 811 

TUBE-SILICONE .188X.375 PE FB80 

1 ea.  Connects barb fitment to tube port. 

2D  FIX 1048 

FITTING-1/4X1/4 BARB FB80 

1 ea.  Connects syrup tube to silicone tube. 

3 ELE 

932DLX

 

PUMP & SANITIZER CABLE 
HARNESS – CTP DLX 

Provides power to the syrup and sanitizer 
pumps.  

 

 

 

Содержание CTP 80BEV-DLX

Страница 1: ...port contact one of our qualified distributors PLEASE READ FIRST This supplement is not a full operations manual It does not contain complete information on installing and maintaining your new system...

Страница 2: ...1 PAGE INTENTIONALLY LEFT BLANK...

Страница 3: ...tal Notices 5 Parts Identification Function 7 Equipment 46 Connecting the Unit Syrup Line and Pump Harness Cable 46 Installing the Electronics Box and Power Connections 48 Filling the Sanitizer Tank 5...

Страница 4: ...use harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the fo...

Страница 5: ...system should be cleaned daily to ensure the highest standard of sanitation When your equipment is delivered or if it has been unused for more than 24 hours follow the DAILY OPENING PROCEDURES in you...

Страница 6: ...or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved NOTE Chi...

Страница 7: ...6 PAGE INTENTIONALLY LEFT BLANK...

Страница 8: ...SS 80BLD 80FCB 80CBB systems OR 3 4 INJ 424P PREMIUM BLENDING ASSEMBLY 1 0 FOR CBB SYSTEMS Blends syrups into the product 1 for 80CBB systems 0 for 80SS 80BLD 80FCB systems OR 3 5 ADPT TY80S FCB MODIF...

Страница 9: ...5800A SPARE PARTS KIT 1 0 FOR SS SYSTEMS Houses extra spare parts and wear items 1 for 80SS systems 0 for 80BLD 80BEV 80CBB 80FCB systems OR 13 2 SPR 5800BLD SPARE PARTS KIT TOUCHSCREEN FLAVOR BLEND...

Страница 10: ...9 PAGE INTENTIONALLY LEFT BLANK...

Страница 11: ...10 General Cabinet Overview Figure 1...

Страница 12: ...opening front panel 6 FAS 2014 8 32 X 1 2 PAN HEAD SCREW 2 Fastens the handle to front door panel 7 RUB 618 RUBBER BUMPER W WASHER 4 Provides spacing between cabinet base and table 8 FAS 2064 10 32 X...

Страница 13: ...12 Outer Cabinet Figure 2 3 1 2 11 10 7 12 4 5 9 8 6 13 26001 See Figure 3 Inner Cabinet 14 See Figure 5 Electronics Parts and Connections...

Страница 14: ...hen attached 1 for 80SS 80BLD 80CBB systems 0 for 80BEV 80FCB systems OR 8 2 MIS 3028 80M SH SANITIZER FLUSH TUBE ASSEMBLY FROZEN BEVERAGE INT 1 0 FOR BEV SYSTEMS Flushes flavor lines with sanitizer w...

Страница 15: ...0 for 80BEV 80FCB 80CBB systems OR 18 2 SYR 926 PERISTALTIC SYRUP PUMP BEVERAGE 8 0 FOR BEV FCB SYSTEMS Pumps syrup from bags into flavor lines 8 for 80BEV 80FCB systems 0 for 80SS 80BLD 80CBB system...

Страница 16: ...15 PAGE INTENTIONALLY LEFT BLANK...

Страница 17: ...16 Inner Cabinet Figure 3...

Страница 18: ...be connectors 3D INJ 116 LINE COUPLER NUT BLACK 1 ea Attaches flavor tubes to flavor manifold 3E SYR 901 6 9 TUBE ASSEMBLY TUBES 9 ea Brings syrup from pump to Injector Head 3F ROT 511 LINE COUPLER NU...

Страница 19: ...zer door 10A RUB 659 TAYLOR ADAPTER O RING 8750 1 ea Creates tension to secure adapter to freezer door 10B ADPT 8750 CROWN ADAPTER WITOUT O RINGS 1 ea Attaches Injector Assembly to freezer door 10C RU...

Страница 20: ...tates product for even syrup distribution 4 SYR 932 6 9 TUBE ASSEMBLY 1 Supplies syrup to Blending Head from pumps 4A FAS 2051 ROLLED FLANGE EYELET 18 ea Provides tension in syrup line to affix to lin...

Страница 21: ...cket to the vertical adjustment bracket 11E FAS 2024 8 32 x 1 4 PAN HEAD SCREW 2 ea Secures the door bracket to the vertical adjustment bracket 11F FAS 2035 8 32 NUT EXT WASHER 2 ea Locks the screws i...

Страница 22: ...UPLER 2 ea Holds flavor lines in place 3C ROT 515 C 9 TUBE ASSEMBLY WAVE SPRING 1 ea Provides tension between tube connectors 3D INJ 116 LINE COUPLER NUT BLACK 1 ea Attaches flavor tubes to flavor man...

Страница 23: ...even syrup distribution 9C FAS 2023 ACCESSORY MOUNTING BRACKET KNOB 1 ea Secures base Mounting Bracket to Gear Box 10 ADPT 104R A CROWN ADAPTER WITH O RINGS 1 Attaches Blending Assembly to freezer do...

Страница 24: ...ER 2 ea Holds flavor lines in place 3C ROT 515 C 9 TUBE ASSEMBLY WAVE SPRING 1 ea Provides tension between tube connectors 3D INJ 116 LINE COUPLER NUT BLACK 1 ea Attaches flavor tubes to flavor manifo...

Страница 25: ...bly 12 ADPT 8750 A CROWN ADAPTER WITH O RINGS 1 Attaches Blending Assembly to freezer door 12A RUB 659 TAYLOR ADAPTER O RING 8750 1 ea Creates tension to secure adapter to freezer door 12B ADPT 8750 C...

Страница 26: ...25 PAGE INTENTIONALLY LEFT BLANK...

Страница 27: ...26 CBB Blending Assembly and Related Parts Figure 4D...

Страница 28: ...ispensed 3B FCB 115 8 32 X 1 PLAS STAND OFF 1 ea Connects the two screws of the assembly 3C FAS 2024 8 32 X M SCREW P H SS 1 ea Remains as a stationary screw 4 SYR 932FCB 6 9 TUBE ASSEMBLY FCB 1 Suppl...

Страница 29: ...28 FCB Door Spout Assembly and Related Parts Figure 4E...

Страница 30: ...SE 1 4 1 ea Prevents pump tube from slipping 1E FAS 2051 ROLLED FLANGE EYELET 1 ea Creates tension for tighter fit 1F FIX 1036 1 4 TO 1 4 OD UNION ELBOW 1 ea Connects syrup in tube to pump 1G FIX 1035...

Страница 31: ...ter fit connects pump to fitment 1D FIX 1035 1 4 TO 3 16 OD REDUCING UNION 1 ea Connects syrup pump to flavor line out 1E FIX 1036 1 4 TO 1 4 OD UNION ELBOW 1 ea Connects bag connector assembly to fla...

Страница 32: ...UP PUMP CLAMP HOSE 1 4 1 ea Prevents pump tube from slipping 1E FAS 2051 ROLLED FLANGE EYELET 1 ea Creates tension for tighter fit 1F FIX 1036 1 4 TO 1 4 OD UNION ELBOW 1 ea Connects syrup in tube to...

Страница 33: ...32 Premium Beverage Syrup Pump and Related Parts Continued Figure 5C...

Страница 34: ...anitizer to sanitizer flush tubes 1C FIX 1046 FLUSH TUBE Y CONNECTOR 1 ea Splits sanitizer flush tube into two tubes OR 1 3 MIS 3028S X PUMP FLUSH ADAPTER EXTENSION 1 0 FOR FCB SYSTEMS Flushes flavor...

Страница 35: ...34 Sanitizer Pump and Related Parts Continued Figure 6...

Страница 36: ...IZER TANK DOME NUTS 1 ea Mounts check valve to Sanitizer Tank 3C FIX 1052 SANITIZER TANK QUICK CONNECT 1 ea Connects sanitizer lines to Sanitizer Tank 3D SAN 755 SANITIZER TANK CAP 1 ea Allows Sanitiz...

Страница 37: ...36 Syrup Tray Sanitizer Tank 9 Tube Assembly Lead and Casing Figure 7...

Страница 38: ...S 2173 FLAT WASHER 18 8 S S 2 ea Secures the connection between bolt and nut 3 MIS 3220 TOUCH PANEL SIDE MOUNTING BRACKET ASSEMBLY 1 0 FOR BEV FCB SYSTEMS Secures the Touch Panel to the freezer 1 for...

Страница 39: ...y gears to spin product in the Injector Head 1 for 80BLD 80CBB systems 0 for 80FCB 80BEV 80SS systems OR 14 3 ELE 530 FCB SPIGOT SWITCH ASSEMBLY KIT 1 0 FOR FCB SYSTEMS Activates the syrup pumps when...

Страница 40: ...he Touch Panel to the cabinet 25 ELE 926 RJ45 ETHERNET CABLE INTERNAL 1 Connects the Ethernet cable to the electronics board 26 FAS 2008 4 40 X 3 8 PAN HEAD SCREW 4 Attaches the ethernet plate to the...

Страница 41: ...40 Electronic Parts and Connections Figure 8...

Страница 42: ...ter 7 RUB 632 LOWER ADAPTER O RING 1 Helps secure the adapter to Injector Head 8 RUB 652 RSS SMALLER SYRUP PORT O RING 1 Provides sealed cavity inside syrup port 9 RUB 660 LARGER SYRUP PORT O RING 1 P...

Страница 43: ...adapter 7 RUB 632 LOWER ADAPTER O RING 1 Helps secure the adapter to Blending Head 8 RUB 652 RSS SMALLER SYRUP PORT O RING 1 Provides sealed cavity inside syrup port 9 RUB 660 LARGER SYRUP PORT O RIN...

Страница 44: ...RUB 627 UPPER ADAPTER O RING FOR ADPT 104R A 1 Secures adapter to freezer door with tension 6 RUB 632 LOWER ADAPTER O RING 1 Secures adapter to Blending Head with tension 7 RUB 652 RSS SMALLER SYRUP...

Страница 45: ...r door 6 RUB 632 LOWER ADAPTER O RING 1 Creates tension to secure adapter to Blending Head 7 RUB 652 RSS SMALLER SYRUP PORT O RING 1 Provides sealed cavity inside syrup port 8 RUB 660 LARGER SYRUP POR...

Страница 46: ...B 660 LARGER SYRUP PORT O RING 1 Seals the cavity inside the syrup port 5 INJ 201A SYRUP MANIFOLD 1 Connects flavor line to the door spout 6 FAS 2140 440 x 5 8 PHILLIPS P H SS SCREW 1 Secures the magn...

Страница 47: ...EM WHERE AMBIENT TEMPERATURES ARE BETWEEN 60 AND 80 DEGREES FAHRENHEIT FOR CORRECT OPERATION NOTE INSTALL THE SYSTEM IN A LOCATION WHERE ITS USE AND MAINTENANCE IS RESTRICTED TO TRAINED PERSONNEL Refe...

Страница 48: ...sket against the coupler Then align the coupler pins of the two tube assemblies and connect them 7 Thread the 9 Tube Assembly coupler nut onto the Lead s casing and tighten to secure 8 Gently lay the...

Страница 49: ...away from the Electronics Box Leave the Rotor Cable connected to the board 3 Insert the white plastic end of the pump harness cable from the back of the cabinet through the opening where the cover pla...

Страница 50: ...t on the back panel 12 Use the four screws of the Electronics Box to mount the box to the back panel of the Deluxe Cabinet The Electronics Box needs to be mounted with the connections at the bottom to...

Страница 51: ...nce every 30 days It is approved by the NSF for cleaning the internal parts of the system like the pumps and syrup lines But it is formulated to be used within a few hours after mixing after which it...

Страница 52: ...line free 3 Remove the Sanitizer Tank from the cabinet 4 Set the Sanitizer Tank upright and remove the cap 5 Fill the Sanitizer Tank with sanitizer NOTE SET ASIDE THE REMAINING SANITIZER SOLUTION FOR...

Страница 53: ...P Power Connections and Power Up Installing Flavors and Priming Syrup Lines Color Touch Panel Overview Consult your standard manual for important information and instructions on these topics Daily Ope...

Страница 54: ...panel inside the cabinet Complete for quick reference when this information is requested 1 Model Number ___________________________________ 2 Serial Number ____________________________________ 3 Volta...

Отзывы: