background image

REGENT

RADIANT CONVECTOR GAS FIRE

Installation and Maintenance Instructions
Hand these instructions to the user

Model No’s FRGCN0MN & FRGCP0MN are for use on Natural Gas

(G20) at a supply pressure of 20 mbar in G.B. / I.E.

Содержание Regent FRGCN0MN

Страница 1: ...RADIANT CONVECTOR GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No s FRGCN0MN FRGCP0MN are for use on Natural Gas G20 at a supply pressure of 20 mbar in...

Страница 2: ...o Pre Cast Flue Installations 8 1 9 Hearth Fitting 8 1 10 Spillage Monitoring System 8 Section 2 2 1 Packing Check List 9 2 2 Installation of Fire 9 10 2 3 Gas Connection 11 2 4 Gas Tightness 12 Secti...

Страница 3: ...at Input 2 0 kW Cold Pressure 20 0 1 0 mbar 8 0 0 4 in w g Ignition Rotary piezo integral to gas valve Electrode Spark Gap 4 0 mm Weight Packed 19kg Firebox Dimensions with case fitted Width 710mm Hei...

Страница 4: ...mneys Flues 5 B S 1251 Open Fireplace Components 6 B S 715 Metal Flue pipes for Gas Appliances 7 B S 1289 Clay Flue blocks and Terminals 8 B S 7566 Installation of factory made Chimneys Ventilation Re...

Страница 5: ...es not project more than 150 mm If the shelf overhangs more than 150 mm the distance between the fire and the shelf must be increased by 25 mm for every 25 mm of additional overhang over 150 mm 1 5 SI...

Страница 6: ...during or after the smoke pellet test and it is important to check inside upstairs rooms adjacent to the chimney flue Check the chimney pot terminal and general condition of the chimney brickwork or...

Страница 7: ...may be fitted if necessary providing that a minimum clearance 50mm between its open end and nearest obstruction is always maintained Fig 1 Chimney Catchment Space 1 8 2 Fitting to Pre Fabricated twin...

Страница 8: ...be removed when installing directly onto a hearth The hearth material must be a minimum thickness of 13 mm with the top surface at least 50 mm above the floor level The hearth must be fitted symmetric...

Страница 9: ...E 2 2 1 Preparation a Remove the dress guard by springing the location wires out at the top and lifting away See Fig 2 Take care not to scratch the trim Fig 2 Remove the Dress Guard b Remove the flue...

Страница 10: ...e If there is a definite flow into the opening then proceed with the instal lation If there is not a definite flow into the opening pre heat the chimney for about two minutes and retest for flow If th...

Страница 11: ...using 8 mm rigid tubing The gas connection can be made left hand right hand or rear In line with current installation regulations a restrictor should be fitted to the inlet pipework to isolate the app...

Страница 12: ...first into the radiant canopy and then lowering and seating the base of the radiants into the radiant support channel b Refit the dress guard 3 2 Lighting the Appliance a Light the pilot by depressing...

Страница 13: ...xercise after a further 5 10 minutes Note It is recommended that the smoke match is fitted into an approved smoke match holder when checking for clearance of combustion products Fig 4 e If the smoke i...

Страница 14: ...me a slight odour may be noticed this is due to the newness of the fire and will soon disappear 3 4 Final Check a Refit the Dress guard if it has not already been re fitted b Recheck the operation of...

Страница 15: ...whole set should be replaced with a genuine replacement set After any servicing work a gas tightness check must always be carried out 4 1 GENERAL ACCESS FOR SERVICING 4 1 1 TO REMOVE THE UPPER CANOPY...

Страница 16: ...FIRE a Disconnect the appliance from the gas supply Remove the front panel by unscrewing the retaining bolt below the front panel as shown in Fig 7 below Fig 7 b Remove the front bezel by unscrewing t...

Страница 17: ...Remove the four burner retaining screws as shown below in fig 9 Disconnect the pilot assy and slide the burner carrier to the right and lift clear Fig 9 17 Front bezel retaining screws Burner Fixing...

Страница 18: ...crewing the rear panel fixing screws then the base panel retaining screw as shown below in fig 10 Fig 10 c Disconnect the pipes to the control valve and the control valve locknut as shown below in Fig...

Страница 19: ...ot assembly a Remove the front panel and front bezel as described in section 4 2 b Unscrew the pilot fixing screws These can be accessed from the front of the appliance with the front panel and bezel...

Страница 20: ...available from specialist spares stockists whose details can be found on our web site www cfm europe com in the stockist section Ceramic Plaques Set FC P079648 Gas valve B 63250 ODS Pilot Assy NG B 4...

Страница 21: ...nstructions This section of the instructions should be read by the user before operating the appliance and retained for future reference Model No s FRGCN0MN FRGCP0MN are for use on Natural Gas G20 at...

Страница 22: ...purpose made additional ventilation is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation which is issued by...

Страница 23: ...ich must be removed The chimney should also be checked to ensure clearance of flue products We recommend that during the annual service replacement of the Oxypilot is carried out After installation or...

Страница 24: ...ation of combustion products from the fire is affected by a partially or fully blocked flue If this system operates the fire will go out If this occurs leave the fire for at least three minutes then f...

Страница 25: ...control knob for slightly longer d When the pilot has lit release the control knob from the depressed position depress slightly again and turn the control anti clockwise to the high position WARNING...

Страница 26: ...umulate on the ceramics can easily be cleaned Carefully remove the ceramics and brush gently with a soft brush To remove the ceramic remove the dress guard as shown in fig 2 Remove the radiants by lif...

Страница 27: ......

Страница 28: ...he radiant plaque sitting against the support bracket as shown Due to our policy of continual improvement and development the exact accuracy of descriptions and illustrations cannot be guaranteed Part...