Solid Fuel Stoves Manual v4. Issued - 22/07/2014 (348)
SOLID FUEL HEATING STOVES
MULTI-FUEL MODELS
INSTALLATION AND OPERATING INSTRUCTIONS
LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER!
All Flavel Stoves exceed the safety and performance requirements of European Standards
Intermittent burning solid fuel roomheaters for installation with a single dedicated chimney.
Flavel No1
Flavel No2
Fuel
Wood (Beech)
Mineral Fuel
(Anthracite)
Wood (Beech)
Mineral Fuel
(Anthracite)
Test Standard
EN 13240:2001+A2 2004
Test Cycle
1.15kg over 0.75hrs
0.76kg over 1.1hrs
1.51kg over 0.72hrs
1.05kg over 1.0hrs
Settings
Primary 0,
2nd 25mm
Primary 30, 2nd 25mm
Primary 0,
2nd 25mm
Primary 35,
2nd 20mm
Flue Draught Pa (ins WG)
12 (0.05)
12 (0.05)
12 (0.05)
12 (0.05)
Efficiency %
78.8
78.2
78.2
77.3
Recommended Rating kW
4.9
4.9
6.9
6.9
Mean Flue Gas Temp Rise ºC
226
216
280
292
Minimum air entry requirement
2700 mm ²
3800 mm ²
Minimum Clearance to combustibles (allow min
50mm clearance to non-combustibles)
350mm
300mm
E
m
is
si
o
n
s
a
s
if
0
2=
13
%
NOx mg/m³
44
-
77
-
CO %
0.19
0.10
0.14
0.08
CxHy mg/m³
169
-
94
-
Gas flow g/sec
4.6
5.4
5.4
6.1
Smoke Emission mg/m³
38
21
74
36
I declare that this information is true, these products meet the requirements of Harmonised Standards and are fit for sale.
Signed on behalf of the manufacturer by Glyn Hughes, Design Engineer, at Winster, Derbyshire, England 22. Jul. 2014
Read these instructions! Use only recommended fuels!
This document, when completed by the installer, constitutes part of a 'Hearth Notice' for purposes of
Building Law. It must be left with the householder and placed where it can easily be found.
INSTALLED AT LOCATION:
BY:
EMERGENCY CONTACT:
Flue Draught
measured on
commissioning:
Fuel used on
commissioning
I definitively assert that this installation is safe, has been lit and demonstrated to the
householder, conforms with current building regulations and with these instructions
SIGNED: DATE:
TO FIND A QUALIFIED INSTALLER, FUEL SUPPLIER or CHIMNEY SWEEP,
CONTACT:
UK:
The Solid Fuel Association, 7 Swanwick Court, Alfreton, Derbyshire DE55 7AS
Tel:0845-601-4406 www.solidfuel.co.uk
RoI:
Irish Nationwide Fireplace Organisation, 162 Capel Street, Dublin 1 Tel:01-801-
5959 www.fireplace.ie
Trentham Lakes, Stoke on Trent, Staffordshire, England ST4 4TJ
www.bfm-europe.com Tel 01782 339000 Fax 01782 339009
These Flavel stoves may be used in smoke control areas when operated
strictly in accordance with these instructions and with Soliftec Smoke
Advice Sheet No1 (
www.soliftec.com/smokeadvice.htm
), when burning:
UK:
Untreated wood logs or authorised smokeless fuels (
Exempted from s20
of the Clean Air Act 1993
)
RoI:
Wood logs, smokeless fuels or peat briquettes, but not petroleum coke
(Control of Atmospheric Pollution Regulations, 1970)
1
Pa
WG
PRODUCTION NUMBER