All Flavel Stoves exceed the safety and performance requirements of European Standards

Intermittent burning solid fuel roomheaters for installation with a single dedicated chimney.

  

Flavel No1

Flavel No2

Fuel 

Wood (Beech)

 Mineral Fuel

(Anthracite)

Wood (Beech)

 Mineral Fuel

(Anthracite)

Test Standard

EN 13240:2001+A2 2004

Test Cycle

1.15kg over 0.75hrs

0.76kg over 1.1hrs

1.51kg over 0.72hrs

1.05kg over 1.0hrs

Settings

Primary 0, 

2nd 25mm

Primary 30, 2nd 25mm

Primary 0, 

2nd 25mm

Primary 35, 

2nd 20mm

Flue Draught Pa (ins WG)

12 (0.05)

12 (0.05)

12 (0.05)

12 (0.05)

Efficiency %

78.8

78.2

78.2

77.3

Recommended Rating kW

4.9

4.9

6.9

6.9

Mean Flue Gas Temp Rise ºC

226

216

280

292

Minimum air entry requirement

2700 mm ² 

3800 mm ²

Minimum Clearance to combustibles (allow min 
50mm clearance to non-combustibles)

350mm

300mm

E

m

is

si

o

n

a

if 

0

2=

13

%

NOx mg/m³

44

-

77

-

CO %

0.19

0.10

0.14

0.08

CxHy mg/m³ 

169

-

94

-

Gas flow g/sec

4.6

5.4

5.4

6.1

Smoke Emission mg/m³ 

38 

21

74

36

I declare that this information is true, these products meet the requirements of Harmonised Standards and are fit for sale. 
Signed on behalf of the manufacturer by Glyn Hughes, Design Engineer, at Winster, Derbyshire, England 22. Jul. 2014

Read these instructions! Use only recommended fuels! 

This document, when completed by the installer, constitutes part of a 'Hearth Notice' for purposes of  
Building Law. It must be left with the householder and placed where it can easily be found.

INSTALLED AT LOCATION:

BY:

EMERGENCY CONTACT:

Flue Draught
measured on

commissioning:

Fuel used on

commissioning

I definitively assert that this installation is safe, has been lit and demonstrated to the 
householder, conforms with current building regulations and with these instructions

SIGNED:                                                                                DATE:

TO FIND A QUALIFIED INSTALLER, FUEL SUPPLIER or CHIMNEY SWEEP,

CONTACT:

UK: 

The Solid Fuel Association, 7 Swanwick Court, Alfreton, Derbyshire DE55 7AS

Tel:0845-601-4406 www.solidfuel.co.uk

RoI:

 Irish Nationwide Fireplace Organisation, 162 Capel Street, Dublin 1 Tel:01-801-

5959 www.fireplace.ie

Trentham Lakes, Stoke on Trent,  Staffordshire, England ST4 4TJ 

 www.bfm-europe.com  Tel 01782 339000  Fax 01782 339009

These Flavel stoves may be used in smoke control areas when operated

strictly in accordance with these instructions and with Soliftec Smoke

Advice Sheet No1 (

www.soliftec.com/smokeadvice.htm

), when burning:

UK: 

Untreated wood logs or authorised smokeless fuels (

Exempted from s20

of the Clean Air Act 1993

)

RoI: 

Wood logs, smokeless fuels or peat briquettes, but not petroleum coke 

(Control of Atmospheric Pollution Regulations, 1970)

 1

Pa

WG

PRODUCTION NUMBER

Содержание MULTI-FUEL SOLID FUEL HEATING STOVES

Страница 1: ...acturer by Glyn Hughes Design Engineer at Winster Derbyshire England 22 Jul 2014 Read these instructions Use only recommended fuels This document when completed by the installer constitutes part of a Hearth Notice for purposes of Building Law It must be left with the householder and placed where it can easily be found INSTALLED AT LOCATION BY EMERGENCY CONTACT Flue Draught measured on commissionin...

Страница 2: ... extra provides the correct fresh air for combustion and ventilation via a flexible tube from outside without draughts across the room and meets the complete requirements of UK and RoI Building Regulations FITTING FREE STANDING MODELS Fasten the flue outlet and blanking plate to the top or back flue outlet Screw 2 L brackets down to a solid non combustible hearth conforming to building regulations...

Страница 3: ...onger Cracks in the ends a hollow sound when tapped and bark falling away are all signs that a log may be ready for use The fine white residue produced when wood burns is not ash but the remains of cell walls which can burn if kept hot enough so don t de ash the fire until absolutely necessary when using wood For best performance and always for low smoke emission Split logs lengthways for drying U...

Страница 4: ...higher nearby such as a tree hill or high building Fitting an anti downdraught cowl to the chimney top can cure this Types which cannot be swept through are not recommended POOR CHIMNEY DRAUGHT Chimney draught in use MUST be at least 12Pa CHIMNEY FIRE In the rare event of deposits inside the chimney igniting roaring sound dense smoke and sparks from the chimney immediately close the door shut all ...

Отзывы: