Kenilworth
&
Linear Coal
DECORATIVE FUEL EFFECT GAS FIRE
Installation and Maintenance InstructionsHand these instructions to the user
Model No. FRDC**MN is for use on Natural Gas (G20) at a supply
pressure of 20 mbar in G.B. / I.E.
Страница 1: ...Linear Coal DECORATIVE FUEL EFFECT GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No FRDC MN is for use on Natural Gas G20 at a supply pressure of 20 mbar...
Страница 2: ...em 9 Section 2 Installation of Fire 2 1 Unpacking the fire 10 2 2 Installing the fire box 10 16 2 3 Gas tightness and inlet pressure 17 Section 3 Assembling Fuel Bed and Commissioning 3 1 Assembling t...
Страница 3: ...ith standard trim no spacer 586mm Width with linear trim no spacer 484mm Height with linear trim no spacer 595mm Depth overall without fender 170mm Depth Flush fit from mounting face to rear 170mm Dep...
Страница 4: ...ts Concrete Flue Blocks 8 I S 813 1996 Domestic Gas Installation Republic of Ireland No purpose made additional ventilation is normally required for this appli ance when installed in G B When Installi...
Страница 5: ...150mm 1 5 FLUE CHIMNEY INSPECTION Before commencing installation a flue or chimney should be inspected to ensure that all the following conditions are satisfied 1 Check that the chimney flue only ser...
Страница 6: ...ied out during commissioning of the appliance 1 6 FIRE PLACE OPENING AND CHIMNEY CATCHMENT SPACE The front opening of the fire place must be between 375 and 440 mm wide and between 550 and 570mm high...
Страница 7: ...e for use in fireplaces fitted with an existing chairbrick without the need for removal of the chairbrick providing the minimum depth of the fireplace exceeds 260mm If the depth is less than 260mm the...
Страница 8: ...a pre cast flue block complying with BS EN 1858 In accordance with BS EN 1858 pre cast flues built with directly plastered faces front or rear are not correctly installed as to ensure proper operatio...
Страница 9: ...h the fire is operated The following are impor tant warnings relating to this spillage monitoring system 1 The spillage monitoring system must not be adjusted by the installer 2 The spillage monitorin...
Страница 10: ...ruction book and Installation book 2 2 INSTALLING THE FIRE BOX Establish which type of flue you are intending to install the fire in to 225 x 225mm 9 inch x 9 inch brick built chimneys 175mm 7 inch di...
Страница 11: ...ge and carefully lift the fire box into the fire opening then slide it back into position Check that the fire box flange fits flush to the sealing face of the fire surround or wall with no gaps presen...
Страница 12: ...n to the appliance should be made to the isolating inlet elbow using 8mm rigid tubing There must be no soldered joints within the firebox See fig 5a 5b below for suggested concealed pipe layouts Fig 5...
Страница 13: ...which in turn will damage the burner and control systems of the product Fig 6 below shows a correctly sealed installation Fig 6 PLEASE NOTE Only holes to be left are the specifically sized air relief...
Страница 14: ...ed around the perimeter of the firebox in a goalpost arrangement to ensure a seal is achieved to the fireplace To fit using the preferred cable method proceed as follows e Mark out and drill 4 off No...
Страница 15: ...nut i Fit a screwed nipple on to each of the cables and pull hand tight up against the tensioning screw then secure each nipple with a flat bladed screwdriver See fig 8 below Fig 8 j Evenly tighten th...
Страница 16: ...aused to the gas control valve on the fire The other firebox fixing method is as follows In installations where the cable method is not suitable e g loose masonary in rear of fire opening the firebox...
Страница 17: ...ol knob for a few seconds to purge the pipe work then press the igniter button The burner should light continue to hold the control knob for a few seconds then turn to the full on position d Check tha...
Страница 18: ...t and is not lodged on the burner See fig 10 below Fig 10 b Position the two halves of the front ceramic L H R H on the locating channel in the front ceramic ensuring it is located onto the lip on the...
Страница 19: ...hey are evenly spaced Use the recess s in the front ceramic rail as a guide for placement See fig 12 below Fig 12 d Select four of the large coals and arrange behind the front row of coals ensuring th...
Страница 20: ...along the rear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See fig 14 below Fig 14 f Select the two small coals and position to fill the gaps at each end of the...
Страница 21: ...e articles is kept to a minimum during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust accumulated in and around the appliance before and after working o...
Страница 22: ...t but the pilot will remain lit g Slightly depress the control knob and turn to the off position the pilot will now be extinguished WARNING If the fire goes out for any reason or is turned off and it...
Страница 23: ...ith the fan running on maximum and all interconnecting doors open f After ensuring that the fire is safe to use it should be left on high position to fully warm up During this time a slight odour may...
Страница 24: ...e location Remove the loose coals from the fuel bed and front ceramic rail Remove the front ceramic from the rail Unscrew the two pozi driv fixing screws which secure the burner heat shield and remove...
Страница 25: ...e Oxy Pilot Assembly Note Because this appliance is fitted with an atmosphere sensing Oxy Pilot it is not possible to replace the thermocouple separately because the thermocouple position is factory s...
Страница 26: ......
Страница 27: ......
Страница 28: ...Rear Fibre Board B 56230 Lower Rear Fibre Board B 56220 Piezo Igniter B 1320 Ignition Wire B 39030 Gas Valve B 102880 L H Fibre Board Linear B 68940 R H Fibre Board Linear B 68930 Upper Rear Fibre Bo...