PowerFLARM Core Manual v.150 International
23
Core has internal memory for around 100 hours of flight recording
at a 4s interval. Flight recording automatically starts when the air-
craft starts moving and ends when the Core is switched OFF or after
more than 10 minutes of standstill. When the memory is full, the
oldest flights are overwritten first.
To read out the flights to the USB stick:
•
Switch Core OFF after flight (allow at least 2 minutes after
landing to avoid losing data).
•
Connect USB stick to Core.
•
Switch Core ON.
•
Observe Status LED (flashing RED/GREEN) or progress in-
dication on display to verify flights are being copied.
•
Wait until system has started up normally after copying
flights.
•
Disconnect USB stick.
Some displays or flight computers allow reading out flights without
switching the Core OFF after the flight. Please refer to your system’s
documentation for details.
Please use FAT formatted USB 2.0 sticks. See the USB section for
details and recommendations about USB stick usage.
Feature licenses
Starting with Firmware version 3.00, some features of the Core
require a license. These features are:
•
AUD: Audio output connection (available from Hardware
version 1.1)
•
ENL: Engine noise level sensor
•
IGC: IGC approval
•
TIS: Garmin TIS interface
•
RFB: Second FLARM antenna connector