Содержание THC-175DF

Страница 1: ...MERCIAL Certifié selon CGA 2 14 M2011 Conforme à la norme ANSI Z83 7 2011 Convient à une utilisation intérieure ou extérieure Sans évent Sans surveillance 26 Benfield Drive St Catharines Ontario Canada L2S 3V5 Tél 905 685 4243 Fax 905 685 0113 ...

Страница 2: ...S PEUVENT UTILISER OU ENTRETENIR CET APPAREIL POUR TOUTE ASSISTANCE OU POUR TOUTE INFORMATION SUPPLÉMENTAIRE MANUEL D UTILISATION ÉTIQUETTES ETC VEUILLEZ CONTACTER LE FABRICANT AVERTISSEMENT MAINTENIR LES COMBUSTIBLES TELS LES MATÉRIAUX DE CONSTRUCTION LE PAPIER ET LE CARTON À DES DISTANCES SÉCURITAIRES TEL QU INDIQUÉ DANS LE MANUEL D UTILISATION NE JAMAIS LAISSER L APPAREIL DANS DES ESPACES CONTE...

Страница 3: ...ILISER OU ENTREPOSER DE L ESSENCE OU D AUTRE VAPEURS OU LIQUIDES INFLAMMABLES À PROXIMITÉ DE L APPAREIL LE CHAUFFAGE DOIT ÊTRE INSTALLÉ SUR UNE SURFACE NIVELÉE INSTALLATION L installation de cet appareil doit se conformer aux normes locales et en l absence de telles normes avec le Code National des Gaz Combustibles ANSI Z233 1 NFPA 54 et le Code d Installation de Gaz Naturel et de Propane CSA B149...

Страница 4: ...les cylindres enlevés du chauffage afin de les entreposer selon les conditions stipulées dans les normes régissant l entreposage et la manutention de gaz de pétrole liquéfiés ANSI NFPA 58 et les normes régissant les installation de gaz naturel et de propane CSA B149 00 GAZ NATUREL Le régulateur doit être utilisé si la pression de l appareil dépasse 14 WC Branchez le régulateur au conduit d aliment...

Страница 5: ...rallonge de diamètre approprié DISTANCES À MAINTENIR ENTRE LE CHAUFFAGE ET LES COMBUSTIBLES DESSUS 5 pi DEVANT 2 pi CÔTÉS 1 pi ARRIÈRE 2 pi CONDUIT LES CONDUITS DU FABRIQUANTS DOIVENT ÊTRE UTILISÉS AVEC CET APPAREIL DE CHAUFFAGE NUMÉRO DE PIÈCES TCHP WD12 HITEX 12 X 12 PI ET AVEC UN MAXIMUM DE 12 PIEDS DE CONDUIT SEULEMENT SIGNICATION DE CHACUN DES VOYANT LUMINEUX LUMIERE VERTE CONSTANTE COURANT A...

Страница 6: ...saleté Note Ne pas utiliser de l air comprimé à l intérieur des tuyaux ou des composants du régulateur INSTRUCTIONS DE DÉMARRAGE 1 Assurez vous que la vanne de sélection de combustible de l appareil est à la bonne position Propane ou Gaz Naturel AVERTISSEMENT L opération de cet appareil avec la vanne en mauvaise position pourrait causer des blessures ou endommager l appareil 2 Pour la PL Branchez ...

Страница 7: ... 1 Fermez la source d alimentation en combustible 2 Réglez les commutateurs du BRÛLEUR sur OFF 3 Attendez 2 3 minutes avant de régler le commutateur du ventilateur sur OFF 4 Débranchez la source d alimentation en combustible ...

Страница 8: ...pipe PROBLEM NO HEAT FAN OPERATES POSSIBLE CAUSE Rear of heater is blocked REMEDY Ensure rear of heater is unobstructed and proper rear clearances are maintained see approval label for specifications POSSIBLE CAUSE If the rear of the heater is obstructed the snap disc manual reset limit may trip and must be reset manually before the fan can operate REMEDY The high temperature limit switch reset bu...

Страница 9: ...t Check igniter wire connections Ensure igniter spark is strong Replace igniter assembly if necessary POSSIBLE CAUSE Ignition Board REMEDY Ensure electrical signals for igniter and gas valve solenoid are present Ensure ignition board is properly grounded POSSIBLE CAUSE Thermostat REMEDY Ensure that the thermostat is calling for heat if it is the fan will start Please not that as a safety measure t...

Страница 10: ...t is calling for heat NOTE If the thermostat is not calling for heat the heater will not operate PROBLEM ELECTRICAL POSSIBLE CAUSE All components REMEDY Before replacing any component all connections must be checked to ensure the electrical circuit is complete Use volt meter and enclosed wiring diagram Any point in the circuit where 120v is not achieved indicates location of problem and or possibl...

Страница 11: ... THC 175DF NEWER MODELS HAVE POWER INDICATOR LIGHT P N THCP 154A THCP 123A THCP 144 THCP 126 THCP 122 THCP 124 THCP 110B THCP 108A THCP 113 THCP 114 THCP 145 THCP 131 THCP 111 THCP 143 THCP 121B THCP 125L THCP 154A ...

Страница 12: ...FOR DUAL FUEL MODELS THERE IS A FUEL SELECTOR VALVE ON THE MANIFOLD P N THCP 155A THCP 109 THCP 105 THCP 106A THCP 104 THCP 102 THCP 101 THCP 109 THCP 119 THCP 116 ...

Страница 13: ...R PROUVANT DE VOILE THCP 110B LAME DE FAN THCP 114 ASSEMBLAGE D ALLUMAGE ET DETECTEUR THCP 102 BRULEUR THCP 101 FIL D ALLUMAGE ELECTRONIQUE THCP 103A TRANSFORMATEUR 120 24V THCP 104 ORIFICE THCP 116 CHANGEMENT DE FAN OU DE BRULEUR THCP 111 VALVE DU GAZ 24V THCP 105 CONTROLE D IGNITION THCP 106A HARNAIS DE FILAGE THCP 107A CORDE D ELECTRIQUE THCP 121B ...

Страница 14: ...29 LOQUET DE CHAFFAGE THCP 131 LA CHARNIERE DE PORTE THCP 132 INDICATEUR THCP 154A SUPPORT POUR THERMOSTAT THCP 165 20 FT CORD THCP TH CORD THERMOSTAT C W 20 FT CORD THCP TH BOUTON POUR THERMOSTAT TH KNOB LES POIGNEES DE COTE THCP 122 PIED ARRIERE THCP 126A POIGNEES ARRIRE RETRACTABLE EN ACIER ENSEMBLE DE SUPPORT THCP 123A ...

Страница 15: ...116 ORIFICE POUR THC 175DF THCP 119 SUPPORT D ORIFICE THCP 121B FIL D ALIMENTATION ÉLECTRIQUE THCP 122 POIGNÉES LATÉRALES CHAQUE DEUX SONT REQUISES THCP 123A POIGNEE ARRIERE RETRACTABLE EN ACIER INOYDABLE THCP 123BR ENSEMBLE DE SUPPORT DE MONTAGE POUR THCP 123A THCP 124 ROUES 10 CHAQUE DEUX SONT REQUISES THCP 125L ESSIEU LONG THCP 126 SUPPORT ARRIERE THCP 128A ASSEMBLAGE DE TUYAU 1 2 X 15PI 1 2 SA...

Страница 16: ...OSTAT 20 TH KNOB BOUTON POUR THERMOSTAT ACCESSOIRES THCP WD12 CONDUIT BLANC 12 X 12PI INCL ADAPTEUR THCP DA12 ADAPTATEUR DE CONDUIT THCP DD DIFFUSEUR DE CONDUIT THCP HD175 DIFFUSEUR DE CHALEUR POUR THC 175 THCP TH ENSEMBLE DE THERMOSTAT B42R0 5 RÉGULATEUR 1 2 DEUXIÈME ÉTAGE ...