6
Absorbed power
Typebetegnelse
Varmesektion
Tilslutnings-
spænding
Optagen
effekt
Optagen
strøm
Min. sikring
i installation
FKE 169 EG
VSFK 169 G
400 V
9kW
13,0 A
16 A
FKE 169 EG
VSFK 169 G
3 x 230 V
9kW
22,6 A
25 A
FKE 1615 EG
VSFK 1615 G
400 V
15kW
21,6 A
25 A
FKE 1615 EG
VSFK 1615 G
3 x 230 V
15kW
37,6 A
40 A
FKE 1621 EG
VSFK 1615 G
400 V
21KW
30,3 A
32 A
FKE 2515 G
VSFK 2515 G
400 V
15kW
21,6 A
25 A
FKE 2515 G
VSFK 2515 G
3 x 230 V
15kW
37,6 A
40 A
FKE 2521 G
VSFK 2521 G
400 V
21kW
30,3 A
32 A
FKE 2010 G
VSFK 2010 G
400 V
10kW
21,6 A
25 A
FKE 2010 G
VSFK 2010 G
3 x 230 V
10kW
37,6 A
40 A
FKE 2014 G
VSFK 2014 G
400 V
14kW
30,3 A
32 A
FKE 169 DG
VSFK 169 G
400 V
2x9kW
13,0 A
16 A
FKE 169 DG
VSFK 169 G
3 x 230 V
2x9kW
22,6 A
25 A
FKE 1615 DG
VSFK 1615 G
400 V
2x15kW
21,6 A
25 A
FKE 1615 DG
VSFK 1615 G
3 x 230 V
2x15kW
37,6 A
40 A
FKE 1621 DG
VSFK 1621 G
400 V
2x21KW
30,3 A
32 A
FKE 3629 TG
VSFK 1615 G
VSFK 2014 G
400 V
1x15KW
1x14KW
21,6 A
30,3 A
25 A
32 A
FKE 3619 TG
VSFK 169 G
VSFK 2010 G
400 V
1x9KW
1x10KW
13 A
21,6 A
16 A
25 A
Please notice that Friomat fryers in double version are equipped with two heat sections.
4
Safety and risk
4.1 Safety instructions, built in
The heat section has a built-in magnet switch which cuts off the power to the heat elements when
the heat section is raised from the worktop.
The electronically control is equipped with an acoustics alarm which is activated, if any
temperature above 250°C is recorded.
4.2 Precaution
The heat section has a built-in mechanical safety thermostat which disconnects the power, if the
Содержание Friomat FKE 1615 DG
Страница 1: ...1 User Manual for Friomat fryer Floor model Version 6 0 OKT 2016...
Страница 13: ...13 9 Specifications for spare parts FKE 16 20 25 36...
Страница 15: ...15 10 Wire diagram FKE HEATING SECTION VSFK 16 OG 25 SERIES...
Страница 17: ...17 HEATING SECTION VSFK FKE 20 SERIES...
Страница 22: ...22...
Страница 23: ...23...
Страница 24: ...24 Bygh jvej 5 Verninge DK 5690 Tommerup Danmark Tlf 45 6475 1066 info fki dk www fki dk...