background image

BENEFITS 

Helps  provide  relief  from  allergy,  asthma  and  other 
respiratory illness. 
Helps  clear  a  smoky  environment  quickly,  so  everyone 
can work and relax together. 
Helps reduce the time and money spent on cleaning and 
redecorating.    Prevents  damaging  black  dust  from 
staining walls, upholstery and window coverings. 
Helps reduce tobacco, cooking and pet odors. 
Revitalizes the air with healthy negative ions. 
Improves  indoor  air  quality  for  a  fresher,  more 
comfortable environment, year-round. 

 

HOW IT WORKS 

Dirty air is drawn in through the front grill and passes through 
a 4-stage filtering system. 

The  Prefilter  consists  of  aluminum  mesh  and  a  close  knit 
polymesh.    It  prevents  larger  particles,  lint  and  hair  from 
entering the collecting cell. 

The next step is a 2-Stage Electrostatic Collecting Cell.  The 
dirt  particles  are  charged  with  a  high  positive  voltage  by  a 
series of fine ionizing wires.  The charged particles are drawn 
through to the collecting plates where the dirt adheres to the 
grounded  plates  and  remains  until  the  cell  is  taken  out  and 
washed. Removes particles down to .01 micron (1/2,540,000 
of an inch). 

The  air  is  then  drawn  through  an  Activated  Carbon  Odor  & 
Gas  VOC  (Volatile  Organic  Compound)  Removal  Filter  to 
help  remove  offensive  odors  and  gases.    Clean  air  is  then 
discharged out the top and back of the Air Cleaner. 

Dual  Negative  Ionizer  needles,  controlled  by  a  separate 
switch,  are  located  in  the  clean  air  stream.    Adding  healthy 
negative ions to the air revitalizes the air similar to that near a 
waterfall,  spring,  ocean,  or  after  a  rainfall.    Studies  have 
shown that negative ions have a beneficial effect on human 
biochemistry, both physically and mentally. 

 

OPERATING INSTRUCTIONS 

1.  Lean  Air  Cleaner  on  side  panel  and  pull  out  of  box.    If 

your unit has any signs of damage, immediately contact 
the store where the Air Cleaner was purchased. 

2.  Keep  the  shipping  carton  and  packaging  in  case  the 

need arises to store or transport the unit. 

3. 

Casters  are  packaged  inside  the  Air  Cleaner.

  Open 

access door, remove prefilter and collecting cell, remove 
casters, and install casters on bottom of unit. 

4.  Remove all packaging from the unit.  Choose a suitable 

location to allow unobstructed circulation from front and 
top  of  unit.    The  unit  performs  best  when  the  back  is 
against  a  wall.    This  enhances  air  circulation.    Allow  at 

least one inch (2.5 cm) away from back wall. 

5.  Operate Air Cleaner at voltage shown on back of unit. 

6.  The controls for the Air Cleaner are located on the rear 

panel.    To  turn  the  Air  Cleaner  on,  push  the  System 
Switch to the 

ON

 position.  This controls the power to the 

Fan Control Switch and to the power board.  When the 
Fan Control Switch is in the extreme left position, the fan 
is on low; center position is medium; and to the right is 
high speed.  When the System Switch is turned 

ON

, the 

green  Performance  Indicator  Light,  located  behind  the 
front grill should be illuminated. 

7.  The  negative  ions  are  controlled  by  a  separate  switch 

located to the right of the fan control switch.  When the 
switch is 

ON

, the red light will illuminate.  

Note:  The Negative Ion Emitter will not work without 
the System Switch being ON.

 

8.  To access the prefilter, collecting cell or activated carbon 

filter, turn the system switch 

OFF

.  Undo the thumbscrew 

located on the rear panel. 

 
 

ON 
OFF 
 
Low 
Medium 
High 
 
OFF 
ON 

 
 

 
 
 
 
 
 

You  may  notice  a  slight  heat  odor  when  new  unit  is  first 
turned on.  This is normal and will disappear within a 24 hour 
period. 
We  recommend  the  Air  Cleaner  be  run  on  low  or  medium 
speed  for quiet, continuous  or  nighttime  use.    Use the  high 
speed for initial cleaning of heavy concentrations of dirty air 
(i.e. smoke) or after leaving the room. 

You may notice arcing or snapping from the cell.  It is normal 
to hear some arcing when the unit is new or first turned on.  
Arcing in the cell may also be caused by high humidity (over 
80%), after washing, or when a large particle of dirt or hair is 
caught in the cell.  If the arcing is continuous and constant, 
then refer to the Troubleshooting Chart.

 

1 Dirty Air 
 
 
2 Prefilter 
 
 
3 Charging 
   Section 

4 Collecting Cell 
   Plates 
 
5 Odor & Gas 
   Removal Filter 
 
7 Negative Ions 
   and Clean Air 
 
6 Ionizing Needles 

Activated Carbon 
Odor & Gas (VOC)  
Removal Filter 

 

Collecting Cell 

 

Air Flow Direction Arrow 

 

Prefilter 

 

Access Door 

System Switch 

Fan Control 
Switch 

Negative Ion 
Switch 

Содержание 890AIV

Страница 1: ...oke cooking smoke and grease and more down to 0 01 micron Activated Carbon Odor Gas VOC Removal Filter removes Volatile Organic Compounds emitted from common sources within the home and office Dual Negative Ionizer restores the air s natural ion balance Quiet 3 Speed Fan is comfortable for room occupants Performance Indicator Light shows Air Cleaner is operating properly at a glance Mobile Easily ...

Страница 2: ...ll remove casters and install casters on bottom of unit 4 Remove all packaging from the unit Choose a suitable location to allow unobstructed circulation from front and top of unit The unit performs best when the back is against a wall This enhances air circulation Allow at least one inch 2 5 cm away from back wall 5 Operate Air Cleaner at voltage shown on back of unit 6 The controls for the Air C...

Страница 3: ...he Activated Carbon Odor Gas VOC Removal Filter No 89 0810 are available from your retail outlet TROUBLESHOOTING CHART The two Operation Lights located behind the front grill are also used as the high voltage fault indicator If the fan is operating but the lights do not come on then there is a problem in the high voltage circuit To determine the problem turn the Air Cleaner OFF and remove the coll...

Страница 4: ...oft surfaces i e beds sofas 12 Do not use the Air Cleaner when oxygen is being used or when combustible gases are present 13 The Air Cleaner has slots or openings in the cabinet for ventilation purposes to provide reliable operation of the unit and to protect it from overheating These openings must not be blocked or covered 14 The Air Cleaner should be operated only from the type of power source i...

Отзывы: