Содержание FSK-180B-EU

Страница 1: ... Model Indoor Unit Outdoor Unit FSK 450B FSK 360B FSK 240B FSK 180B EU Thanks for your selection of FIHSER Air Conditioning Unit Before use please read this instruction manual carefully and keep it properly to ensure correct use of this machine FSO 450B 3F FSO 360B FSK 360B FSO 360 3F FSO 240B FSO 180B ...

Страница 2: ......

Страница 3: ...peration procedure standard fitting 13 5 Weekly timer optional fitting 23 6 Wire controller with week timer functions 25 7 Optimum operation 34 8 Trouble shooting 35 9 Installation notes 37 10 Care and maintenance 38 11 Instructions of unit installation 39 12 Test operation 59 Error display on the panel 61 Appendix 62 ...

Страница 4: ...1 1 Names and functions of parts indoor unit outdoor unit FSK 180B EU FSO 180B FSK 240B FSO 240B ...

Страница 5: ...2 indoor unit outdoor unit FSK 360B FSO 360B FSK 360B FSO 360B 3F FSK 450B FSO 450B 3F ...

Страница 6: ...2 Safety cautions Read the following carefully to assure safe use 3 NOTE Children should be supervised to ensure that they do not play with the appliance ...

Страница 7: ...y persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 4 ...

Страница 8: ...3 Wire controller standard fitting Never install the wire controller in a place where there is water leakage Avoid bumping throwing tossing or frequently opening the wire controller Fig 1 5 ...

Страница 9: ... 6 For temperature increase For temperature decrease Press this button once the temperature will be increased or decreased by 1 NOTE Lock function Press and at the same time for 5 seconds the set temp indicating area shall Fig 4 display EE and all keys response shall be shut off all buttons will sound and repress the and simultaneously for 5 seconds the lock function will be released When the disp...

Страница 10: ...e when repressing the SWING button that the type style SWING will be disappeared and the unit w st Note The SLEEP function could be set up by wireless remote control 5 Running mode setup Fig 6 When press this button once the operation mode will be changed as follow At COOL mode the COOL icon will light on the current temperature should be set up lower than the ambient temperature If the setting te...

Страница 11: ...be reduced If it is in this case the controller will start defrosting automatically and displays DEFROST icon NOTE There is no HEAT mode in the cooling only unit after the power saving set up the auto mode will be shielded 6 TIMER setup Fig 7 At unit turned off the timer on could be set up at unit turned on the timer off could be set up After pressed the TIMER button the unit could be set up and t...

Страница 12: ... of the out environment After displayed the outdoor environment temperature 10 seconds later the system will back to the room ambient temperature displaying surface Fig 9 NOTE If the unit has been unconnected with the outdoor ambient sensor this function will be unavailable 8 SAVE set up Fig 9 At unit turned off to press the FAN buttons continuously for 5 seconds adjust the Saver set menu at this ...

Страница 13: ...he menu and displays the normal unit off interface The above setting has been completed the system will display SAVE icon no matter by buttons on displayer or the wireless remote control the setting temperature should not exceed the former SAVE setup temperature range for example as show in Fig 9 we set up the cooling lower limit is 23 in SAVE setting the upper limit is 27 the user can set the coo...

Страница 14: ...ey to store the set value and exit the seting 10 Malfunction display Fig 11 When the malfunction happened during operation the displayer will display ERROR icon and flash and meanwhile will display the error code when there are multi malfunction happened the displayer will display the error codes circularly The first number denotes the system number if there is only one system in the display it wi...

Страница 15: ...the right of DEBUG displays setting status Now use the key or the key to select from the following two settings The indoor room temperature is measured at the air intake Now the OUT ENV area displays 01 The indoor room temperature is measured at the wire controller Now the OUT ENV area displays 02 The default room temp sensor is located at the air intake The indoor room temperature is measured at ...

Страница 16: ...mote Control Note Be sure that there are no obstructions between receiver and remote controller Don t drop or throw the remote controller Don t let any liquid in the remote controller and put the remote controller directly under the sunlight or any place where is very hot 13 ...

Страница 17: ...er Note This type of remote controller is a kind of new current controller Some buttons of the controller which are not available to this air conditioner will not be described below Operate on unmentioned buttons would not impact on the normal use 14 ...

Страница 18: ...n room temp and set temp microcomputer can control cooling on or not If room temp is higher than set temp compressor runs at COOL mode If room temp is lower than set temp compressor stops and only indoor fan motor runs Set T EMP should be in range of 16 to 30 15 ...

Страница 19: ... procedure If room temp is lower than set temp compressor runs at HE AT mode If room temp is higher than set temp compressor and outdoor fan motor stop only indoor fan motor runs Set T EMP should be in range of 16 to 30 16 ...

Страница 20: ...speed If room Temp is more than 2 above Set TEMP compressor and outdoor unit fan motor run as COOL mode the indoor unit fan motor runs at low speed 17 If room Temp is between 2 of Set TEMP the compressor and outdoor unit fan motor will run for 6 minutes and stop for 4 minutes and always in such a cycle the indoor unit fan motor will run at low speed ...

Страница 21: ...on procedure According to room temp microcomputer can automatically set COOL HEAT DRY operation mode so as far best effect At AUTO mode operation standard TEMP is 26 for COOL mode 24 for DRY mode and 20 for HEAT mode 18 ...

Страница 22: ...eration procedure Connect the unit to power supply Press the ON OFF key Press the mode key to select the FAN mode The unit shall operate under FAN mode Press the FAN key to select from high medium and low speed 19 ...

Страница 23: ... TIMER operation procedure 20 ...

Страница 24: ... or drying if SLEEP operation is set TEMP would increase 1 in 1 hour and 2 in 2 hours Indoor fan motor runs at low speed When the unit is heating if SLEEP operation is set TEMP would decrease 1 in 1 hour and 2 in 2 hours Indoor fan motor runs at low speed 21 ...

Страница 25: ... How to inser t batteries 22 ...

Страница 26: ...ction is able to realized four timing ON OFF periods for any unit every day so as to achieve fully automatic operation No timing control can be set for holidays Fig 1 This WEEKLY TIMER adopts 485 mode to communicate with manual control of every duct type unit and it can control up to 16 units Adopting 2 core twisted pair wire the longest communication distance of this TIMER is 1200m After connecte...

Страница 27: ...ER will only be prepared when customer orders communication joint with WEEKLY TIMER on manual control had been prepared 1 Press or to select the unit that needed to be control It is available to control several units by Group Control 1 16 or control single unit by Single Control 2 When selected a certain or several units by Single Control or Group Control Timer setting and On off setting can be se...

Страница 28: ...t Temperature Display 12 Timer interval Display 3 Energy Saving Status Display 13 Mode Button 4 Set Temperature Display 14 Set Temperature Increase Button 5 Week Display 15 Set Temperature Decrease Button 6 Fan Speed Display Auto High Speed Medium Speed Low Speed 16 Fan Speed Button 7 Defrosting Status Display 17 Swing Button 8 Fresh Air Status Display 18 Timing Button 9 Mode Cooling Dehumidifying...

Страница 29: ...ess the setting temperature button For temperature increase For temperature decrease Press this button once the temperature will be increased or decreased by 1 Note Press button for 5 seconds EE will appear where SET TEMP is displayed and all buttons are shielded Press button again for 5 seconds to cancel locked function If long distance monitoring controller or central controller shield displayer...

Страница 30: ...EAT AUTO In cool mode COOL will light in which case setting temperature should be set to be lower than present ambient temperature If not the unit will not operate in cool mode and only the fan is active In dry mode DRY will light Indoor fan will run at low speed in certain temp range Dry efficiency as well as energy saving efficiency in this mode is much better than that in cool mode In heat mode...

Страница 31: ...ded after setting energy saving 6 Timer Setting Fig 9 10 11 Timer function in this wired controller conneted with weekly timer is invalid and wired controller will be controlled by weekly timer Either in ON status or OFF status of the unit press TIMER button into timing setting and then press or button to set timing Fig 7 set time Fig 8 and delete timing Fig 9 At last press TIMER to set it Fig 9 F...

Страница 32: ...inking characters setting can be continuous till quit It by pressing ON OFF button meanwhile timing data are memorized Fig 12 13 In time setting mode press MODE button to select any desired setting object Week 1 7 min part 0 59 or hour part 0 23 and then press or button to adjust this object which is fixed by pressing TIMER button or can be canceled by pressing Timer again During fixing setting th...

Страница 33: ...l be no display where setting temp is displayed and outdoor ambient temp tested by inner system will be displayed where ambient temp is displayed If outdoor temp is tested to be below zero will be displayed where set temp is displayed and absolute value of outdoor ambient temp tested by inner system will be displayed where ambient temp is displayed After 10 second display the system will return to...

Страница 34: ...ip off the menu and display normal interface of unit off SAVE will be displayed in LCD at next startup of the unit if above setting has been finished Either by pressing buttons of the displayer or remote controller the setting temp can never be set to be higher than temp range set under energy saving mode before For example lower limit cooling temp under energy saving mode is 23 and upper limit is...

Страница 35: ...alfunction happens during operating of the unit ERROR will blink with error code displayed For example the right figure indicates compressor low pressure protection Codes Malfunction E0 Water pump malfunction E1 Compressor high pressure protection E2 Indoor anti freezing protection E3 Compressor low pressure protection E4 Compressor high temp exhaust protection E5 Compressor overload protection E6...

Страница 36: ...the right of DEBUG displays setting status Now use the key or the key to select from the following two settings The indoor room temperature is measured at the air intake Now the OUT ENV area displays 01 The indoor room temperature is measured at the wire controller Now the OUT ENV area displays 02 The default room temp sensor is located at the air intake The indoor room temperature is measured at ...

Страница 37: ...7 Optimum operation 34 ...

Страница 38: ...vice cent er Do not repare the air conditioner by yourself because wrong repair may cause fire please contact service center to do it for you Check item shown below before contacting service center Note If trouble still exists after checking the above items please contact service center 35 Done by professinal done by professinal ...

Страница 39: ... The following are not troubles 36 ...

Страница 40: ...9 Installation notes This should be done by professional 37 ...

Страница 41: ...10 Care and maintenance Please cut off the power supply after you used the air conditioner 38 2 and 3 should be done by professional Done by professinal Cut off power supply before cleaning ...

Страница 42: ...ation spaces 3 4 Select the place where can stand times of the weight of the indoor unit and would not increase the operating noise and oscillate 4 The horizontally of the installation place should be guaranteed 5 Select the place where is easy to drain out the condensate water and connect with outdoor unit 11 ns tructions of unit ins tallation I 260 39 2 Make sure that the installation had accord...

Страница 43: ... to obviate lampblack to prevent the indraft of the lampblack by the air conditioner 2 Keep the air conditioner far from the kitchen so that the lampblack would not be indraft by the air conditioner C Important notice To guarantee the good performance the unit must be installed by professional personnel according with this instruction Please contact the local FIHSER special nominated repair depart...

Страница 44: ...ter lever Tighten double nuts Bolt of one of the angle of outlet pipe is fix on the angle of the drainage slot Fix the install cardboard Fix the gasket firmly Polyethylene pipe Bolt attachment Center of the ceiling opening Bolt attachment Install cardboard Gasket anchor board attachment Nut supplied at scene Hoisting stand Gasket attachment Insert Fig 2 1 The primary step for install the indoor un...

Страница 45: ...te water flow there may be malfunction of the bobber switch and lead water drop 5 Backout the gasket anchor board used to prevent gasket break off and tighten the nut on it 6 Backout the install cardboard Note Please do tighten the nuts and bolts to prevent air conditioner break off F Connect the refrigerant pipe Selection of Connecting Pipe 42 Item Model Gas Max Pipe Length m Max Height Differenc...

Страница 46: ...e nut Wiring interface Spanner Liquid inlet tube Gas collection tube Torque wrench Median sponge attachment entwine the wiring interface with seal mat Thread fasten x4 Smear freeze motoroil here Fig 3 When connect the pipe to the unit or backout it from the unit please do use both spanner and torque wrench as shown in fig 3 When connect smear both inside and outside of the flare nut with freeze mo...

Страница 47: ...radient drain raising pipe should be added To prevent bent of the drain hose the distance between hoisting stand should is 1 to 1 5m wrong Correct 1 100 or more gradient 1 1 5m Use the drain hose and clamp attached Insert the drain hose to the drain vent and then tighten the clamp Below 4mm Sponge attachment Clamp attachment Clamp Drain hose Sponge gray Entwine the big sponge on the clamp of drain...

Страница 48: ...ning capacity of the unit Above100mm T tie in join drain hose Check the smoothness of drain after installation Check the drain state by immitting 600cc water slowly from the outlet vent or test hole Check the drain in the state of refrigerating after installation of the electric circuit Way of immiting Drain hose Test hole cover Test hole Above100mm Drain vent for repair use plastic stopper is inc...

Страница 49: ... manufactory or its service agents or a similarty qualified person in order to avoid a hazard Wiring of unit and the controller 1 Wiring of the indoor unit Remove the control box lid pull the wires inside through rubber bush and wiring according to the WIRING DIAGRAM then tighten it with clamp 2 Wiring of the controller 1 Remove the control box lid pull wires inside through rubber bush and connect...

Страница 50: ...on the panel temporarily to the book of the indoor unit 2 Positions 2 Temporarily hang the remaining 2 latches to the hooks on the sides of the indoor unit be careful not to let the swing motor lead wire get caught in the sealing material 3 Screw all 4 hexagon head screws located right beneath the latches in approximately 15mm panel will rise 4 Adjust the panel by turning it to the arrowed directi...

Страница 51: ...ions 1 Improper screwing of the screws may cause the troubles shown in Fig 5 Fig 5 2 If gap is still left between the ceiling and the panel after screwing the screws readjust the height of the indoor unit body Refer to Fig 6 ...

Страница 52: ... 6 After fixing be sure no gap left between the ceiling and the panel 3 Wiring of the decoration panel Connect the joints for swing flap motor lead wire at 2 places installed on the panel Refer to Fig 7 49 ...

Страница 53: ...llowing principles 1 Outdoor unit shall be installed so that the air discharged by outdoorunit will not return and that sufficient space for repair shall be provided around the machine 2 The installation site must have good ventilation so that the outdoor unit can take in and exhaust 50 E A D B 412 412 1250 572 378 Model Item B 320 C 540 695 D 540 572 E 286 378 1032 1018 412 840 572 378 1018 820 A...

Страница 54: ...ite must be at a place where the air exhaust outlet does not face strong wind D Installation of Condensate Pipe 1 The condensate pipe shall be installed with an inclining angel of 5 10 so as to facilitate the drainage of condensate The joints of the condensate pipe must be covered by thermal insulation materials to avoid generation of exterior condensate 2 A condensate outlet is located at both th...

Страница 55: ...ting pipe must be covered by thermal insulation materials be bundled by adhesive tape and be isolated from air 2 The joint connecting to the indoor unit must be wrapped by thermal insulation material There shall be no gap between the connecting pipe joint and the wall of the indoor unit Refer to Figure 4 无间隙 No Gap Fig 4 Fig 5 Caution After the pipes are wrapped by protective materials never bend ...

Страница 56: ...e wall refer to Figure 6 If concealed installation is adopted 1 PVC pipe can be used Refer to Figure 7 3 No matter if surface mounting or concealed mounting is selected it is required to drill 2 holes in the same level which distance shall be the same as the distance 60mm of installation holes in the bottom plate of the wire controller Then insert a wood plug into each hole Fix the bottom plate of...

Страница 57: ...the signal cable of the wire controller I Power Cable Connection Caution Before installing the electrical equipment please pay attention to the following matters which have been specially pointed out by our designers 1 Check that if the power supply used conforms to the rated power supply specified on the nameplate 2 The capacity of the power supply must be large enough 3 The lines must be install...

Страница 58: ...al power supply line which shall be equipped with electricity leakage switch and air switch so as to deal with overload conditions 3 The air conditioning unit must have grounding to avoid hazard owing to insulation failure 4 All fitting lines must use crimp terminals or single wire If multiple twisted wires are connected to terminal board arc may arise 5 All line connections must conform to the sc...

Страница 59: ...ect the power cable to the terminal and earthing screws marked L1 L2 L3 N 5 Use cable fastener to bundle and fix the cable 11 5 Products Electric Installation Wiring layout Installation should be conducted by National Wiring Regulation The rated voltage and exclusive power supply must be adopted for the air conditioners The power cable should be reliable and fixed in order to avoid the wiring term...

Страница 60: ... f and be fixed by screw otherwise it would cause electric shock Theuser must offer the reliable grounding terminal Please don t connect the grounding wire to the following places Water pipe 1 Gas pipe 2 Blowing pipe 3 4 Other places that professional personnel consider them unreliable The section area of cables selected by users must not be smaller than the specifications show diagram Warning 3 4...

Страница 61: ...e communication wire co nnection between indoor and outdoor The signal wire between indoor and outdoor unit shall be installed in the shielded bushing Warning FSK 240B FSK 180B EU FSO 240B FSO 180B FSK 360B FSO 360B FSK 360B FSO 360B 3F FSK 450B FSO 450B 3F ...

Страница 62: ...ting 1 Turn on the power switch and press ON OFF button 2 Press MODE button select COOL HEAT FAN etc to test whether it operates normally 3 Emergency operation When the batteries fail or when the remote controller is missing operate as shown below On stopping you can press the AUTO button on cover NO Ⅱ until it is in AUTO mode The cover NO Ⅱis the part of the panel As the below picture 59 ...

Страница 63: ...hat shown on the nameplate The unit may malfunction or the components burn out Are wiring and piping correct The unit may malfunction or the components burn out Is the unit safely grounded Risk of electric leakage Is wiring size according to specifications The unit may malfunction or the components burn out Is something blocking the air outlet or intake of either the indoor or outdoor unit It may ...

Страница 64: ...lb fails Compressor Indicating Lamp green it flashes when the compressor is on and goes out when the compressor is off It flashes when an error about the defrosting or the compressor occurs It flashes once on the condition of the mode conflict It flashes twice on the condition of defrosting It flashes three times on the condition of the high pressure It flashes four times on the condition of the l...

Страница 65: ... improvement of products in which case the values on nameplate shall prevail Appendix Air conditioner nominal working condition and working range Note Indoor side Outdoor side Test condition DB WB DB WB Nominal cooling 27 19 35 24 Nominal heating 20 7 6 Rated cooling 32 23 43 26 Rated heating 27 24 18 Low temp heating 20 7 8 4 In this table the outdoor side DB temperature of low temp cooling inclu...

Страница 66: ......

Страница 67: ......

Страница 68: ...This product must not be disposed together with the domestic waste This product has to be disposed at an authorized place for recycling of electrical and electronic appliances 66129906996 ...