11.2 Installation for hydronic module
11.2.1 Select the best location
There should not be any heat source or steam near the unit.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
Recommended installation height for indoor unit shall be at least 800 mm.
Must install on a vertical wall.
When install electrical equipment at wooden building of metal lath or wire lath, according to
electrical facility technical standard, no electrical contact between equipment and building is
allowed. Insulator must be installed in between.
Do not install the unit at outdoor. This is designed for indoor installation only.
11.2.2 Installation dimensions
(1) Wall mounted panel size. (mm)
The mounting wall is strong and solid enough to prevent it from vibration.
Always mount the installation plate horizontally plate by aligning the marking thread and using
a level gauge.
Mount the installation plate on the wall with 8 sets of plug, bolt and washer (all non-supply)
with different size.
(2) Space required for installation and maintenance. (mm)
Содержание FHIF-WHS-120CE3
Страница 2: ......
Страница 9: ...R32 ATW Service Manual 7 1 2 2 Hydronic module FHIF WHS 120CE3 FHIF WHS 160CE3...
Страница 18: ...R32 ATW Service Manual 16 Pic 4 3 Domestic hot water mode operation range...
Страница 23: ...R32 ATW Service Manual 21 8 System diagram...
Страница 24: ...R32 ATW Service Manual 22 9 Wiring diagram 9 1 Outdoor unit 9 1 1 9 1 2 FHOF WHS 100CE3 FHOF WHS 160CE3 3F...
Страница 28: ...R32 ATW Service Manual 26 Main PCB 3 Hydronic module Main PCB...
Страница 29: ...R32 ATW Service Manual 27 Filter board...
Страница 34: ...R32 ATW Service Manual 32 Model FHOF WHS 160CE3 3F...
Страница 35: ...R32 ATW Service Manual 33 Single unit installation More than one unit installation Unit mm...
Страница 46: ...R32 ATW Service Manual 44 HEATING MODE COOLING MODE...
Страница 47: ...R32 ATW Service Manual 45 HEATING MODE WITHOUT COOLING MODE DHW MODE WITHOUT COOLING MODE...
Страница 48: ...R32 ATW Service Manual 46 HEATING MODE WITHOUT DHW MODE AND DHW TANK ONLY DHW MODE...
Страница 56: ...R32 ATW Service Manual 54 When the unit has error code alarm port has a 220V output...
Страница 59: ...R32 ATW Service Manual 57...